Search Results

Refine
1 - 12 of 35 Products for 'Microsecond' Page 1 of 3 |

Microsecond

kW PowerMax Pro Sensor

kW PowerMax Pro Sensor

--> kW PowerMax-Pro Sensor Kilowatt class power measurement with extended average power handling capability up to 3 kW with a 20 microsecond rise time and utilizing the same transverse thermoelectric thin-film HD sensor technology as our standard PowerMax-Pro sensor. Contact Us About This Product…

LabMax-Pro SSIM

LabMax-Pro SSIM

…sample every 50 microseconds), enabling real-time analysis of modulated or pulsed systems.
* Snapshot mode provides burst sampling at a rate of 625 kHz (a sample every 1.6 microseconds), enabling users to view the temporal pulse traces of modulated lasers in the tens of microseconds or longer,…

PowerMax-Pro Sensor

PowerMax-Pro Sensor

…utilizes a unique thermal flow design enabling fast, high power measurement, with high damage resistance. The sensor is so fast, less than ten microseconds in the case of the “HD” version, that users can trace the pulse shape of modulated lasers at pulse repetition frequencies up to 25 kHz. In…

COHR PowerMax-Pro 15mm DS 0619 6.pdf

COHR PowerMax-Pro 15mm DS 0619 6.pdf

…offers the broad wavelength sensitivity and large dynamic range of a thermopile with the fast response speed of small infrared detectors. The microsecond response time enables nearly instant power measurement without any overshoot, and can provide pulse energy, peak power, and rise/fall time with…

COHR PowerMax-Pro 15mm OEMdetectors DS 0619 3.pdf

COHR PowerMax-Pro 15mm OEMdetectors DS 0619 3.pdf

…(Patent #9,012,848) offers the broad wavelength sensitivity, large dynamic range of a thermopile with a fast ten microsecond response speed. FEATURES & BENEFITS · High-speed 10 microsecond response time · High-power handling to 9 W · Supports lasers from 400 nm to 11 microns · Broadband coating…

Avia preinstall.book

Avia preinstall.book

…time in microseconds.
This time is the minimum time the RF can be off while q-switching in
Pulse Delete and ThermEQ modes
PRINT DELAY TIME
?DT
Returns the Delay Time in microseconds.
PRINT MODE1 DELAY TIME
?DT1
Returns the RePumpTime (DT1) in microseconds for…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…the thin film configuration is in the microsecond range.This enables the sensor to provide an essentially instant
power measurement without any overshoot and also enables pulse analysis of modulated lasers with pulses greater than 10
microseconds.
EnergyMax - Laser Energy Sensors

LabMax-Pro SSIM User Manual

LabMax-Pro SSIM User Manual

…thermopile--which has a
sensing time constant value of several seconds--the time constant
for the thin film configuration is in the microsecond range. This
enables the sensor to supply an essentially instant power measurement without any overshoot--refer to Figure 2-5, below. The

Whitepaper LMC PM-Pro LAM updtd 3 05 19.pdf

Whitepaper LMC PM-Pro LAM updtd 3 05 19.pdf

…flow thermopile, which has a sensing time constant value of several
seconds, the time constant for the thin film configuration is in the microsecond range. This enables
the sensor to provide an essentially instant power measurement without any overshoot. Coherent's
first product based…

Layout 1

Layout 1

…thermopile, which has a sensing
time constant value of several seconds,
the time constant for the thin film configuration is in the microsecond range.
This enables the sensor to provide an
essentially instant power measurement
without any overshoot. Coherent's first

Ted Haensch  Sharing His Unique Perspective on Lasers

Ted Haensch Sharing His Unique Perspective on Lasers

…artist view of our approach,
together with an experimental hyperspectral image. Such an approach can
simultaneously measure, on the microsecond timescale, all spectral elements
over a wide bandwidth and with high
resolution on a single photodetector.
We therefore expect that…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…Manual
Trigger source Internal Internal
Trigger level 20% 20%
Trigger edge Rising Rising
Trigger delay 0 microseconds 0 microseconds
Trigger bus participation mode Not bussed Not bussed