Search Results

Refine

Result Type

1 - 12 of 30 Products for 'Mirror Mount' Page 1 of 3 |

Mirror Mount

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

mirrors is mounted on a
piezo-electric (PZT) actuator. The resonator mirror with the least alignment sensitivity was
selected for this role. In order to correct for both acoustic noise (linewidth narrowing) and
thermal drift (long-term wavelength stabilization), the PZT mirror

Laser Focus World - September 2014

Laser Focus World - September 2014

…x misalignment y misalignment 30 25 20 15 10 5 0 Misalignment (µrad) Misalignment events Shock test misalignments Old mirror mounts Shock test misalignments New mirror mounts b) 450 to 499 350 to 399 400 to 449 250 to 299 300 to 349 150 to 199 200 to 249 50 to 99 100 to 149 0 to 49 x misalignment…

Self-Aligned Non-Dispersive External Cavity Tunable Laser.pdf

Self-Aligned Non-Dispersive External Cavity Tunable Laser.pdf

…with a 1 by 2 m emission facet area and with a mirror mounted adjacent the
emission facet. Fig.2(c) right shows the TO-can laser diode mounted in a tube holding a
collimating lens inside and with the VHG mounted on top. The mirror is mounted
approximately 0.3 mm above the laser chip…

Sample manuscript showing specifications and style

Sample manuscript showing specifications and style

…a 1 by 2 m emission
facet area and with a mirror mounted adjacent the emission facet. Fig.2(c) right shows the TO-can laser diode mounted
in a tube holding a collimating lens inside and with the VHG mounted on top. The mirror is mounted approximately 0.3
mm above the laser chip and…

Mira brochure

Mira brochure

…P2 external control
Pump focus lens
Cavity mirror M4
900-P Gires-Tournois
with ß-lock
GVD prism P1
900-P fold mirror M-8
900-F high reflector M7
Birefringent filter
tuning element
Ti:S crystal mount
The
inside
story of productive work.…

COHR WP OPSL No Green Noise final 5.15.18.pdf

COHR WP OPSL No Green Noise final 5.15.18.pdf

…active thermal stabilization of the cavity as well as the
ability to lock the cavity length and etalon performance together using piezo mirror mounts and
feedback electronics. This all adds cost and complexity.
Some commercial low-noise DPSS lasers are based on other active feedback…

Vitara Preinstall.book

Vitara Preinstall.book


while maintaining high-quality mode. The cavity also features automated modelocking initiation by means of a solenoid-driven
movable mirror mount.
Verdi G-series
Laser Head
Based on optically pumped semiconductor laser (OPSL) technology,
the Verdi G-series is a robust…

High Power 7-GHz Bandwidth External-Cavity Diode Laser Array and Its Use in Optically Pumping Singlet Delta Oxygen.pdf

High Power 7-GHz Bandwidth External-Cavity Diode Laser Array and Its Use in Optically Pumping Singlet Delta Oxygen.pdf

…beam collimation. (a) and (b) are views into fast-axis (FA) plane
and slow-axis (SA) plane, respectively.
The VBG is mounted on a modified Newport mirror mount and it can be aligned by finely
rotating around the DLA's slow-axis and fast-axis. VBG is thermoelectrically cooled with

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

Diamond J-3-5 Series OEM Lasers Preinstallation Manual, Rev. AA

…Laser Resonator The resonator assembly consists of a two mirror optical cavity with
fluid-cooled rectangular shaped (slab design) electrodes extending
the length of the resonator compartment. An RF matching network
is mounted on top of the resonator compartment within the RF

COHR THzSpectroscopyBrochure 0219 2.pdf

COHR THzSpectroscopyBrochure 0219 2.pdf

…Immersion or contact probe tips may be mounted with either a fixed SwageLok mount, or for longer probes
that may need alignment, an adjustable tip/tilt probe mount. The Vial/Tablet Sample Holder incorporates an adjustable steering
mirror, interchangeable focusing lens, and safety…

Diamond J-5 Series OEM Lasers Preinstallation Manual, Rev. AC


is mounted on top of the resonator compartment within the RF
power module compartment and coils attached to the electrodes are
positioned to create a uniform distribution of RF energy along the
electrodes (see Figure 2-4).
One of the 100% reflecting end mirrors partially…

00 E-250 Pre.book

00 E-250 Pre.book

…Laser Resonator The resonator assembly consists of a two mirror optical cavity with
fluid-cooled rectangular shaped (slab design) electrodes extending
the length of the resonator compartment. An RF matching network
is mounted on top of the resonator compartment within the RF

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions