COHR ChameleonVision-S DS 0119 3.pdf

COHR ChameleonVision-S DS 0119 3.pdf

…VAC (MRU)
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz) 47 to 63
MECHANICAL PARAMETERS
Weight of Laser Head 52 kg (115 lbs.)
Weight of Power Supply 33 kg (73 lbs.)
Umbilical Length 3 m (10 ft.)
Dimensions (L x W x H)
Chiller
MRU

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply <8 at 90 VAC
Chiller <14 at 90 VAC
MRU <2 at 90 VAC
System Power Consumption (W) 2300
Line Frequency (Hz) 47 to 63
Communications/Control Interfaces1 RS-232, USB, Ethernet…

COHR ChameleonVision-S DS 0517 3.pdf

COHR ChameleonVision-S DS 0517 3.pdf


Dimensions (L x W x H)
Chiller 436 x 270 x 393 mm (17.17 x 10.63 x 15.47 in.)
MRU Air Recirculator 46 x 43 x 8.5 cm (18 x 17 x 3 in.)
Weight
Chiller 11 kg (25 lbs.)
MRU Air Recirculator: 9 kg (20 lbs.)
1 At 800 nm
2 Average speed measured over entire tuning…

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

…Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply <8 at 90 VAC
Chiller <14 at 90 VAC
MRU <2 at 90 VAC
System Power Consumption (W) 2300
Line Frequency (Hz) 47 to 63
Communications/Control Interfaces1 RS-232, USB, Ethernet…

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply <8 at 90 VAC
Chiller <14 at 90 VAC
MRU <2 at 90 VAC
System Power Consumption (W) 2300
Line Frequency (Hz) 47 to 63
Communications/Control Interfaces1 RS-232, USB, Ethernet…

COHR ChameleonDiscovery TPC DS 1117 5.pdf

COHR ChameleonDiscovery TPC DS 1117 5.pdf

…Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply <8 at 90 VAC
Chiller <14 at 90 VAC
MRU <2 at 90 VAC
System Power Consumption (W) 2300
Line Frequency (Hz) 47 to 63
Communications/Control Interfaces1 RS-232, USB, PC…

COHR ChameleonDiscovery DS 1218 2.pdf

COHR ChameleonDiscovery DS 1218 2.pdf

…Total Power Control
Operating Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply
Chiller
MRU
<8 at 90 VAC
<14 at 90 VAC
<2 at 90 VAC
System Power Consumption (W) 2300
Line Frequency (Hz) 47 to 63

COHR ChameleonDiscovery TPC DS 1218 2.pdf

COHR ChameleonDiscovery TPC DS 1218 2.pdf

…Total Power Control
Operating Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply
Chiller
MRU
<8 at 90 VAC
<14 at 90 VAC
<2 at 90 VAC
System Power Consumption (W) 2300
Line Frequency (Hz) 47 to 63

ChameleonUltra DS 16-02-16  F.pdf

ChameleonUltra DS 16-02-16 F.pdf

…to 250 VAC (auto ranging)
Maximum Operating Current <15A at 90 VAC (power supply)
<7A at 90 VAC (chiller)
<2A at 90 VAC (MRU X1)
System Power Consumption 2300W max., 1300W typical
Line Frequency 47 to 63 Hz
Operating Temperature Range 15 to 35°C (59 to 95°F)…

ChameleonVision DS 0216 3.pdf

ChameleonVision DS 0216 3.pdf

…90 to 250 (auto ranging)
Maximum Operating Current (A) <15 at 90 VAC (power supply)
<7 at 90 VAC (chiller)
<2 at 90 VAC (MRU x1)
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz) 47 to 63
Operating Temperature Range 15 to 35°C (59 to…

COHR ChameleonVision DS 0119 5.pdf

COHR ChameleonVision DS 0119 5.pdf

…(rad/nm) <80/100
Operating Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply
Chiller
MRU x1
<15 at 90 VAC
<7 at 90 VAC
<2 at 90 VAC
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz)…

COHR ChameleonUltra DS 0119 3.pdf

COHR ChameleonUltra DS 0119 3.pdf

…90 to 250 VAC (auto ranging)
Maximum Operating Current <15A at 90 VAC (power supply)
<7A at 90 VAC (chiller)
<2A at 90 VAC (MRU X1)
System Power Consumption 2300 W max., 1300 W typical
Line Frequency 47 to 63 Hz
Operating Temperature Range 15 to 35°C (59 to…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions