Search Results

Refine

Result Type

1 - 10 of 10 Products for 'Mru Xi' Page 1 of 1 |
  • 1

Mru Xi

ChameleonUltra DS 16-02-16  F.pdf

ChameleonUltra DS 16-02-16 F.pdf

…to 250 VAC (auto ranging)
Maximum Operating Current <15A at 90 VAC (power supply)
<7A at 90 VAC (chiller)
<2A at 90 VAC (MRU X1)
System Power Consumption 2300W max., 1300W typical
Line Frequency 47 to 63 Hz
Operating Temperature Range 15 to 35°C (59 to 95°F)…

Discovery ShutDown PowerUp Procedures.pdf

Discovery ShutDown PowerUp Procedures.pdf

…Hour 5 Hour 6
MRU
Chiller × × ×
Laser × × × × ×
Fig 6: Switch-on timetable guide
Hour 1: Switch on MRU
If the air hoses were disconnected between the back of the MRU (fig 3) and laser head (fig 4),
reconnect them (`Air out' and `Air in' of MRU fig 3 to fig 4,…

COHR ChameleonVision-S DS 0119 3.pdf

COHR ChameleonVision-S DS 0119 3.pdf

…VAC (MRU)
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz) 47 to 63
MECHANICAL PARAMETERS
Weight of Laser Head 52 kg (115 lbs.)
Weight of Power Supply 33 kg (73 lbs.)
Umbilical Length 3 m (10 ft.)
Dimensions (L x W x H)
Chiller
MRU

COHR ChameleonVision-S DS 0517 3.pdf

COHR ChameleonVision-S DS 0517 3.pdf


Dimensions (L x W x H)
Chiller 436 x 270 x 393 mm (17.17 x 10.63 x 15.47 in.)
MRU Air Recirculator 46 x 43 x 8.5 cm (18 x 17 x 3 in.)
Weight
Chiller 11 kg (25 lbs.)
MRU Air Recirculator: 9 kg (20 lbs.)
1 At 800 nm
2 Average speed measured over entire tuning…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…90 to 250 (auto ranging)
Maximum Operating Current (A) <15 at 90 VAC (power supply)
<7 at 90 VAC (chiller)
<2 at 90 VAC (MRU x1)
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz) 47 to 63
Operating Temperature Range 15 to 28°C (59 to…

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…90 to 250 (auto ranging)
Maximum Operating Current (A) <15 at 90 VAC (power supply)
<7 at 90 VAC (chiller)
<2 at 90 VAC (MRU x1)
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz) 47 to 63
Operating Temperature Range 15 to 28°C (59 to…

ChameleonVision DS 0216 3.pdf

ChameleonVision DS 0216 3.pdf

…90 to 250 (auto ranging)
Maximum Operating Current (A) <15 at 90 VAC (power supply)
<7 at 90 VAC (chiller)
<2 at 90 VAC (MRU x1)
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz) 47 to 63
Operating Temperature Range 15 to 35°C (59 to…

COHR ChameleonVision DS 0119 5.pdf

COHR ChameleonVision DS 0119 5.pdf

…(rad/nm) <80/100
Operating Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply
Chiller
MRU x1
<15 at 90 VAC
<7 at 90 VAC
<2 at 90 VAC
System Power Consumption (W) 2300 max., 1300 typical
Line Frequency (Hz)…

COHR ChameleonUltra DS 0119 3.pdf

COHR ChameleonUltra DS 0119 3.pdf

…90 to 250 VAC (auto ranging)
Maximum Operating Current <15A at 90 VAC (power supply)
<7A at 90 VAC (chiller)
<2A at 90 VAC (MRU X1)
System Power Consumption 2300 W max., 1300 W typical
Line Frequency 47 to 63 Hz
Operating Temperature Range 15 to 35°C (59 to…

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

…90 to 250 VAC (auto ranging)
Maximum Operating Current <15A at 90 VAC (power supply)
<7A at 90 VAC (chiller)
<2A at 90 VAC (MRU X1)
System Power Consumption 2300W max., 1300W typical
Line Frequency 47 to 63 Hz
Operating Temperature Range 15 to 35°C (59 to 95°F)…