Search Results

Refine

Result Type

1 - 7 of 7 Products for 'Pm 30 Thermopile' Page 1 of 1 |
  • 1

Pm 30 Thermopile

Microsoft Word - kW Thermopile Damage Threshold.doc

Microsoft Word - kW Thermopile Damage Threshold.doc

…intense. The following chart
outlines the safe beam sizes for typical CO2 and Nd:YAG kW lasers.
0
5
10
15
20
25
30
35
40
45
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
Incident Laser Power (watts)
Minimum Beam Diameter

Whitepaper LMC PM-Pro LAM updtd 3 05 19.pdf

Whitepaper LMC PM-Pro LAM updtd 3 05 19.pdf

…product based on this technology, called the PowerMax-Pro, also preserves the main benefits of
the traditional thermopile architecture, namely large active area (30 mm x 30 mm), wide dynamic
range (50 mW to 150W), high damage resistance (14 kW/cm²) and broad wavelength range (300 nm

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…PowerMax-Pro USB/RS HD Sensors 30
PowerMax-Pro USB/RS HP Sensors 31
PowerMax-USB/RS Sensors 32-49
PowerMax-USB/RS Sensor Accessories 50
Power Sensor Summary Specifications (standard DB-25 LM and PM models) 51-52
LM Model Beam Position Sensing Thermopile Sensors (10 mW to 5…

High-Sensitivity-Optical-Power-Sensors.pdf

High-Sensitivity-Optical-Power-Sensors.pdf

…- 514 1 PM DB-25 1098407 PM150 0.19 to 11.0 300 mW 150W 30 mW 1 to 150 19 Broadband - 514 1 PM DB-25 1098398 PM150-50 0.19 to 11.0 300 mW 150W 30 mW 1 to 150 50 Broadband - 514 1 PM DB-25 1098455 PM150X 0.15 to 1.0 300 mW 150W 30 mW 1 to 150 50 UV - 514 1 PM DB-25 Water-Cooled Thermopile Sensors (to…

COHR Air-CooledThermopileSensors DB25 DS 0819 2.pdf

COHR Air-CooledThermopileSensors DB25 DS 0819 2.pdf

…plate
Air-Cooled Thermopile Sensors to 150 W Datasheet
SPECIFICATIONS PM150X
Wavelength Range (µm) 0.15 to 1
Power Range 300 mW to 150 W
Long-Pulse Joules Range (J) 1 to 150
Maximum Intermittent Power (<5 min.) (W) 300
Resolution (mW) 30
Maximum Power…

COHR HighPowerWater-CooledThermopileSensors DB25 DS 0719 1.pdf

COHR HighPowerWater-CooledThermopileSensors DB25 DS 0719 1.pdf

…Density (mJ/cm2) 600
Response Time (sec.) 30
Detector Coating Broadband
Active Area Diameter (mm) 50
Calibration Uncertainty (%) (k=2) ±3
Calibration Wavelength (nm) 1070
Cooling Method Water
Cable Type PM DB-25
Cable Length (m) 2
Part Number 10983923…

LabMax Meters DS 8.qxd

LabMax Meters DS 8.qxd

…Input Range
Thermopile Sensors (LM Model) 50 V to 2V
Thermopile Sensors (PM Model) 20 V to 2V
Optical Sensors 1 nA to 20 mA
Pyroelectric Sensors (-TOP only) 1 mV to 16V
Noise
Thermopile Sensors (LM Model)(V) 1.2
Thermopile Sensors (PM Model)(nV) 500