Pointing Stability

Designing ProvenHands-free Reliability TechNote FinalWeb.pdf

Designing ProvenHands-free Reliability TechNote FinalWeb.pdf

…all opto-mechanical
components to make sure every optical mount and
assembly well exceeds the required level of stability.
Figure 3 shows beam pointing stability data that
confirms the success of this approach. These data
cover 50 hours of continuous operation of a Vitara-T.…

Designing-and-Manufacturing-fs-Ultra-broadband-Lasers-Proven-Hands-free-Reliability-White-Paper.pdf

Designing-and-Manufacturing-fs-Ultra-broadband-Lasers-Proven-Hands-free-Reliability-White-Paper.pdf

…all opto-mechanical
components to make sure every optical mount and
assembly well exceeds the required level of stability.
Figure 3 shows beam pointing stability data that
confirms the success of this approach. These data
cover 50 hours of continuous operation of a Vitara-T.…

COHR CPC1040 DS 0616 5.pdf

COHR CPC1040 DS 0616 5.pdf

…dispersion inherent in the optical paths of commercial and home-built microscope systems. The rugged optical design delivers excellent pointing stability, and power efficiency is optimized through careful coating design. The compact size and simple alignment process makes installation…

Quotation KML QGYYMMDD G  Institute Contact

Quotation KML QGYYMMDD G Institute Contact

…automatic laser beam alignment and pointing stabilization system. It also
includes a convenient real-time laser beam parameter monitoring and logging system. The result
is that the pointing stability of the EUV source exceeds the pointing stability performance of the
driving laser--…

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System


Paladin Advanced 8000/10000 < 550
Paladin Advanced 16000/24000/35000 < 480
Beam Ellipticity 0.9 to 1.1
Pointing Stability (µrad/°C) < 20
Polarization linear > 100:1, vertical
Noise (10 Hz to 2 MHz) < 1% (rms)
Long-term Power Stability < ± 2%

Paladin Advanced Preinstallation.book

Paladin Advanced Preinstallation.book

…Mode TEM00
M2 < 1.2
Beam Diameter (mm) 1 mm ± 10%
Pointing Stability (µrad/°C) < 20
Polarization linear > 100:1, vertical
Noise (10 Hz to 2 MHz) < 1% (rms)
Long-term Power Stability < ± 2%
Maximum Warm-up Time < 15 min. from standby
<…

Microsoft Word - 115-80041-001 Round Module Manual.doc

Microsoft Word - 115-80041-001 Round Module Manual.doc

…Operation CW
Spatial Mode TEM00
Beam Divergence (full) < 1 mrad Typical
Beam Size at Aperture (FWHM) < 1 mm
Beam Pointing Stability < ± 10 µrad
Polarization (typical) > 100:1, vertical or horizontal
Warm-up Time < 5 min
ELECTRICAL
Operating…

COHR AzureNX 266 1000 DS 0618 3.pdf

COHR AzureNX 266 1000 DS 0618 3.pdf

…1.1
Astigmatism ±25% of Rayleigh Range
Pointing Stability (µrad/°C) <±5
Pointing (µrad) (activly stabilized) <20
Transverse Mode TEM00
M2 <1.3
Polarization Linear, Vertical ±3°, 200:1
Output Power Stability over 8 hours (%) <1
RMS Noise (%) (10 Hz…

COHR AVIA NX Green DS 0818 3.pdf

COHR AVIA NX Green DS 0818 3.pdf

…Vertical, ±3°
Beam Pointing Stability (µrad/°C) <25
Pulse Energy Stability (%) (RMS) <5
Power Stability (%) (RMS, 2s) (over 8 hours) <2
Warm-up Time (minutes)
Cold Start
Warm Start
<45
<15
Long-term Pointing Stability at Fixed Rep-rate…

COHR AVIA NX UV DS 0117 5.pdf

COHR AVIA NX UV DS 0117 5.pdf

…Vertical, ±3°
Beam Pointing Stability (µrad/°C) <25
Pulse Energy Stability (%) (RMS) <5
Power Stability (%) (RMS, 2s) (over 8 hours) <2
Warm-up Time (minutes)
Cold Start <45
Warm Start <15
Long-term Pointing Stability at Fixed Rep-rate (rad) ±25…

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…Direction3 Vertical ±3°
Beam Pointing Stability (µrad/°C) <25
Pulse Energy Stability (%)(RMS) <2
Power Stability (%)(RMS, 2s) <2
Warm-up Time (minutes)
Cold Start <45
Warm Start <15
Long-term Pointing Stability at Fixed Rep-rate (rad) ±25 over 8…

COHR Azure DS 0717 4.pdf

COHR Azure DS 0717 4.pdf

…Ellipticity 0.9 to 1.1
Astigmatism ±25% of Rayleigh range
Pointing Stability (µrad/°C) ±5
Transverse Modes/Beam Profile TEM00, M2x <1.3, M2y <1.3
Polarization Vertical, linear, 200:1
Output Power Stability <1% over 8 hours
RMS Noise <0.3% between 10 Hz and…