Search Results

1 - 12 of 310 Products for 'Power Max' Page 1 of 26 |

Power Max

Energy Max Laser Sensors

Energy Max Laser Sensors

…Mutipurpose, high damage threshold, large area, laser energy sensors that allow measurements over a wide range of wavelengths, beam diameters, power levels, and repetition rates. YAG/Harmonics And IR sensors YAG/Harmonics And IR sensors Very high damage threshold, large area, laser energy sensors…

kW PowerMax Pro Sensor

kW PowerMax Pro Sensor

…3 kW Average Power Range¹ (continuous) 1W to 1 kW 1W to 3 kW Maximum Pulsed Peak Power (kW) 1 5 Noise Equivalent Power Standard Mode (10 Hz) <50 mW High Speed Mode (20 kHz) <0.5W Snapshot Mode (625 kHz) <1.5W Maximum Power Density (kW/cm²) 5.0 at 1 kW avg. power 2.4 at 3 kW avg. power Rise Time (μs)…

LMFC Series High Power Multimode Fiber Coupled Laser Modules

LMFC Series High Power Multimode Fiber Coupled Laser Modules

…Typ Max Unit Linewidth (Δλ) 0.06 0.10 0.20 nm Spatial Mode Multimode Noise (RMS, 0.20 MHz) 0.25 0.5 % Power Stability (1 hr) 0.10 0.5 % Electrical Min Typ Max Unit Operating Current 1.5 A Operating Voltage 3.3 VDC Modulation Input (TTL) 0 5 VDC Modulation Speed 3 kHz Environmental Min Typ Max Unit…

PowerMax-Pro USB/RS Sensors

PowerMax-Pro USB/RS Sensors

…Peak Power (W) 200 200 200 200 200 200 (use for >1 μsec pulses up to CW) Maximum Intermittent Power (W) (1 μsec pulses up to CW) Maximum Intermittent Power (W) (<5 min.) 65 (air-cooled) 65 (air-cooled) 150 (maximum) 150 (maximum) 65 (air-cooled) 65 (air-cooled) Noise Equivalent Power (mW) Standard…

FieldMaxII-P

FieldMaxII-P

…from being damaged by overcharging and speeds the process of recharging when the battery is drained. The meter can also be powered by six standard AA batteries Specifications Max. Measurable Energy (with pyroelectric sensor) 300.0J Min. Measurable Energy (with pyroelectric sensor) 1 nJ Displayable…

FieldMaxII-TOP

FieldMaxII-TOP

…AA batteries. Specifications Max. Measurable Power (with thermopile sensor) 30.0 kW Max. Measurable Power (with optical sensor) 300.0 mW Max. Measurable Energy (with pyroelectric sensor) 300.0J Min. Measurable Power (with thermopile sensor) 10 uW Min. Measurable Power (with optical sensor) 1 nW Min.…

FieldMate

FieldMate

…laser power measurements and laser tuning. Specifications Max. Measurable Power (with thermopile sensor) 29.9 kW Max. Measurable Power (with optical sensor) 99.9 mW Min. Measureable Power (with thermopile sensor) 100 µW Min. Measurable Power (with optical sensor) 10 nW Displayable Full-Scale Power

FieldMaxII-TO

FieldMaxII-TO

…PC control Specifications Max. Measurable Power (with thermopile sensor) 30.0 kW Max. Measurable Power (with optical sensor) 300.0 mW Min. Measurable Power (with thermopile sensor) 10 µW Min. Measurable Power (with optical sensor) 1 nW Displayable Full-Scale Power Ranges (with thermopile sensor)…

LabMax-TO

LabMax-TO

--> LabMax-TO Laser Power Meter (RoHS)
* Measures Laser Power
* Ergonomic design enhances user experience
* Compatible with LM- and PM-model thermopile and optical sensors with beam position display
* Data logging to onboard memory and to USB flash drive
* USB and RS-232 PC interfaces
* RoHS…

LabMax-TOP

LabMax-TOP

--> LabMax-TOP Laser Power and Energy Meter (RoHS)
* Measures laser power and energy
* Ergonomic design enhances user experience
* Compatible with LM- and PM-model thermopile and optical sensors with beam position display
* Pulse energy to 10 kHz
* Data logging to onboard memory and to USB flash…

ModeMaster PC M-Squared

ModeMaster PC M-Squared

…peak-to-peak Min. Divergence (mrad) 0.24 0.46 0.24 0.46 Max. Divergence (mrad)d 1.7 3.2 2.0 3.6 Max. Beam Dia. (mm)f 25 12 25 12 a. Wavelength-dependent quantities are input power levels, and minimum and maximum divergence (see notes b, e, f). b. Power levels are proportional to the inverse of the…

QCR Fiber Optic Cable

QCR Fiber Optic Cable

…Close PRICE HERE Tech Spec AR-coating 1030-1090 nm Fiber core dimension SM-300 µm Length 1-20 m Max Beam diameter (1/e²) 8 mm (single-mode) 10 mm (multi-mode) Max Power (CW) 750 W Max Peak power 2.5 kW at 10 ms pulse length 12.5 kW at 1 ms pulse length 250 kW at 50 ns pulse length Transmission…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions