Search Results

1 - 12 of 174 Products for 'Power Max 2' Page 1 of 15 |

Power Max 2

FieldMaxII-TO

FieldMaxII-TO

…PC control Specifications Max. Measurable Power (with thermopile sensor) 30.0 kW Max. Measurable Power (with optical sensor) 300.0 mW Min. Measurable Power (with thermopile sensor) 10 µW Min. Measurable Power (with optical sensor) 1 nW Displayable Full-Scale Power Ranges (with thermopile sensor)…

Energy Max Laser Sensors

Energy Max Laser Sensors

…to connect with any of our global sites. 联系我们 Room 1006 – 1009, Raycom Info Park Tower B, No. 2, Kexueyuan South Road Haidian District Beijing China 100190 email: sales.china@coherent.com Call 02 460 7900 Direct connection to sales team : 02-3419-8039 Direct connection to Service team : 02-460-7999…

ModeMaster PC M-Squared

ModeMaster PC M-Squared

…Noise <2% RMS and <5% peak-to-peak Min. Divergence (mrad) 0.24 0.46 0.24 0.46 0.25e 0.47e Max. Divergence (mrad)d 1.7 3.2 2.0 3.6 2.7 5.0 Max. Beam Dia. (mm)f 25 12 25 12 25 12 a. Wavelength-dependent quantities are input power levels, and minimum and maximum divergence (see notes b, e, f). b. Power

kW PowerMax Pro Sensor

kW PowerMax Pro Sensor

…±2.5 Power Linearity (%) ±3 Back Reflection (%) <1 when used with QBH Adapter 0 Wavelength Range (%) Fixed calibration point ±50 Calibration Wavelength² 810 nm, 1070 nm, 10.6 μm Cooling Method³ Water Cable Type DB25 Cable Length 3m (9.8ft.) ¹ See power handling curve for beam size requirements. ²

FieldMate

FieldMate

…laser power measurements and laser tuning. Specifications Max. Measurable Power (with thermopile sensor) 29.9 kW Max. Measurable Power (with optical sensor) 99.9 mW Min. Measureable Power (with thermopile sensor) 100 µW Min. Measurable Power (with optical sensor) 10 nW Displayable Full-Scale Power

IndyStar Excimer Laser | Coherent

IndyStar Excimer Laser | Coherent

…HERE Fast Pulse, High Precision Processing Model Name Wavelength (nm) Max. Pulse Frequency (Hz) Max. Pulse Energy (mJ) Max. Power (W) IndyStar 1 kHz 193 1000 8 8 IndyStar 2 kHz 2000 4 IndyStar 1 kHz 248 1000 12 12 IndyStar 2 kHz 2000 6 Datasheet IndyStar Applications Application Material Photomask…

LabMax-TO

LabMax-TO

LabMax-TO Laser Power Meter (RoHS)
* Measures Laser Power
* Ergonomic design enhances user experience
* Compatible with LM- and PM-model thermopile and optical sensors with beam position display
* Data logging to onboard memory and to USB flash drive
* USB and RS-232 PC interfaces
* RoHS Compliant…

LabMax-TOP

LabMax-TOP

LabMax-TOP Laser Power and Energy Meter (RoHS)
* Measures laser power and energy
* Ergonomic design enhances user experience
* Compatible with LM- and PM-model thermopile and optical sensors with beam position display
* Pulse energy to 10 kHz
* Data logging to onboard memory and to USB flash drive
*…

FieldMaxII-TOP

FieldMaxII-TOP

…AA batteries. Specifications Max. Measurable Power (with thermopile sensor) 30.0 kW Max. Measurable Power (with optical sensor) 300.0 mW Max. Measurable Energy (with pyroelectric sensor) 300.0J Min. Measurable Power (with thermopile sensor) 10 uW Min. Measurable Power (with optical sensor) 1 nW Min.…

PowerMax-Pro USB/RS Sensors

PowerMax-Pro USB/RS Sensors

…30 x 30 Minimum Beam Size (mm) 2.0 (1.0 mm - up to 3% error) 2.0 (1.0 mm - up to 3% error) 2.0 (1.0 mm - up to 3% error) 2.0 (1.0 mm - up to 3% error) 2.0 (1.0 mm - up to 3% error) 2.0 (1.0 mm - up to 3% error) Calibration Uncertainty (%) (k=2) ±2 ±2 ±2 ±2 ±2 ±2 Power Linearity (%) ±5 ±5 ±5 ±5 ±5 ±5…

PowerMax-Pro Sensor

PowerMax-Pro Sensor

…technological advancement in laser power sensing that combines the broad wavelength sensitivity, dynamic range and laser damage resistance of a thermopile with the response speed of a semiconductor photodiode. This high-speed, thin film sensor technology for laser power measurement (50 mW to 15 kW).…

FieldMaxII-P

FieldMaxII-P

…from being damaged by overcharging and speeds the process of recharging when the battery is drained. The meter can also be powered by six standard AA batteries Specifications Max. Measurable Energy (with pyroelectric sensor) 300.0J Min. Measurable Energy (with pyroelectric sensor) 1 nJ Displayable…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions