Ask a Question
Coherent

Search Results

Refine
1 - 12 of 16 Products for 'Powermax Pm30' Page 1 of 2 |
Related Categories: Pm10 Sensor | Pm10 Detector | Pm2 | Lm10 | Pm10

Powermax Pm30

PowerMax-USB-RS-Sensors-Product-Guide.pdf

PowerMax-USB-RS-Sensors-Product-Guide.pdf

…19 mm aperture Models PM2, PM10, PM30 These thermopile sensors are used to measure CW and pulsed lasers from 5 mW up to 30W average power output.These sensors are able to dissipate heat via convection cooling, which makes them convenient to use. Model PM2 PM10 PM30 Wavelength Range (µm) 0.19 to 11…

PowerMax-USB sensors

PowerMax-USB sensors

…PowerMax-USB PM30 Power Sensor (1174257) PowerMax-USB PS10 Power Sensor (1174260) PowerMax-USB PS19 Power Sensor (1174261), PowerMax-USB PS19Q Power Sensor (1168343) PowerMax-USB UV/VIS Quantum Power Sensors (1168337) Related Materials White Papers PowerMax USB-RS User Manual PowerMax Water Cooled…

PowerMax-RS Sensors

PowerMax-RS Sensors

…Sensor (1174267)
* PowerMax-RS PM30 Power Sensor (1174258) PowerMax-RS PM3K Power Sensor (1191293) PowerMax-RS PS19Q Power Sensor (1179504) Related Materials White Papers PowerMax USB RS User Manual PowerMax Water Cooled OEM Detector Applications Note PowerMax RS Sensor Manual Water cooled Power…

C24 Program

C24 Program

…RS-232 PowerMax PM1K-36C PowerMax PM150-19C PowerMax RS LM-10 PowerMax RS-PM150-50C USB PowerMax USB LM-10 PowerMax USB LM-45 PowerMax PM10-19C PowerMax USB - PM10 PowerMax USB - PM30 PowerMax USB PS10 PowerMax USB PS19 PowerMax USB PS19Q PowerMax USB-PM150-19C PowerMax USB-PM150-50C PowerMax USB…

PowerMax-USB-RS-Sensors-Product-Guide.pdf

PowerMax-USB-RS-Sensors-Product-Guide.pdf

…19 mm aperture Models PM2, PM10, PM30 These thermopile sensors are used to measure CW and pulsed lasers from 5 mW up to 30W average power output.These sensors are able to dissipate heat via convection cooling, which makes them convenient to use. Model PM2 PM10 PM30 Wavelength Range (µm) 0.19 to 11…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…100, 101 PM1K-36C 47 PM1KX 67, 130 PM1KX-100 49, 69 PM2 43, 51 59 PM200F-19 51, 62 PM200F-50 51, 62 PM200F-50X 51, 68 PM2X 44, 51, 66 PM3 40, 51, 58 PM30 43, 51, 59, 128, 129, 130 PM300 51, 61 PM300F-19 51, 62, 128 PM300F-50 51, 62 PM300F-50X 51, 68, 130 PM30V1 52, 65 PM30X 44, 51, 66, 128, 130 PM3K…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…aperture PM2, PM10 and PM30 These thermopile sensors are used to measure CW and pulsed lasers from 5 mW up to 30W average power output.These sensors are able to dissipate heat via convection cooling, which makes them convenient to use. Device Specifications PM2 PM10 PM30 5 mW to 30W PowerMax-USB/RS…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…Models PM2, PM10, PM30 These thermopile sensors are used to measure CW and pulsed lasers from 5 mW up to 30W average power output.These sensors are able to dissipate heat via convection cooling, which makes them convenient to use. Device Specifications PM2 PM10 PM30 5 mW to 30W PowerMax-USB/RS…

PowerMax-USB-RS-Sensors-Product-Guide.pdf

PowerMax-USB-RS-Sensors-Product-Guide.pdf

…19 mm aperture Models PM2, PM10, PM30 These thermopile sensors are used to measure CW and pulsed lasers from 5 mW up to 30W average power output.These sensors are able to dissipate heat via convection cooling, which makes them convenient to use. Model PM2 PM10 PM30 Wavelength Range (µm) 0.19 to 11…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…Models PM2, PM10, PM30 These thermopile sensors are used to measure CW and pulsed lasers from 5 mW up to 30W average power output.These sensors are able to dissipate heat via convection cooling, which makes them convenient to use. Device Specifications PM2 PM10 PM30 5 mW to 30W PowerMax-USB/RS…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…aperture PM2, PM10 and PM30 These thermopile sensors are used to measure CW and pulsed lasers from 5 mW up to 30W average power output.These sensors are able to dissipate heat via convection cooling, which makes them convenient to use. Device Specifications PM2 PM10 PM30 5 mW to 30W PowerMax-USB/RS…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…44, 92, 93 PM1K-36C 37 PM1KX 61, 122 PM1KX-100 61 PM2 39, 43, 51, 58 PM200F-19 43, 54 PM200F-50 43, 54 PM200F-50X 43, 60 PM2X 43, 58 PM3 32, 43, 50 PM30 39, 43, 51, 120-122 PM300 43, 53 PM300F-19 43, 54, 120 PM300F-50 43, 54 PM300F-50X 43, 60, 122 PM30V1 44, 57 PM30X 43, 58, 120, 122 PM3K 37, 44, 55…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions