Search Results

1 - 12 of 22 Products for 'Recirculator' Page 1 of 2 |

Recirculator

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…OPO/OPO SHG tuning
· Enables full multimodal imaging (MPE, SHG,THG and CARS)
· RS-232 and USB interface
· Filtered and dry air recirculation unit to tune across water absorption bands
· Vis and Idler outputs available also as after-sale upgrades
until now, required at least…

DC Series, CO2 Lasers for Cutting

DC Series, CO2 Lasers for Cutting

…cooling provides the highest reliability. The laser operates with only a few extremely durable components and does not need conventional gas recirculation – leading to a considerable reduction of maintenance and service. The gas consumption is also minimized: the integrated gas bottle eliminates…

PowerLine AVIA NX UV Laser Sub-System for micromachining applications

PowerLine AVIA NX UV Laser Sub-System for micromachining applications

…sources to deliver unmatched lifetime. This laser and other system components are all contained in a sealed enclosure which utilizes filtered, recirculated air to minimize contamination from external sources. When service is required, most operations can be performed in the field, without returning…

UV Laser Marking Sub-System | Coherent

UV Laser Marking Sub-System | Coherent

…reliability and rapid field service. The laser and other system components are all contained in a sealed enclosure which utilizes filtered, recirculated air to minimize contamination from external sources. When service is required, various system components, such as the power sensor, purification…

Laser Marking Workstations

Laser Marking Workstations

…Circumferential marking module (oscillating table configuration only)
* Digital readout, motorized or programmable upgrade of Z-Axis
* Refrigerated recirculating water chiller for all LME-RM versions (laser dependent)
* Automated Pick ‘N Place parts handling
* Custom Motion Control ability
* Fume…

COHR ChameleonVision-S DS 0119 3.pdf

COHR ChameleonVision-S DS 0119 3.pdf

…3 m (10 ft.)
Dimensions (L x W x H)
Chiller
MRU Air Recirculator
436 x 270 x 393 mm (17.17 x 10.63 x 15.47 in.)
46 x 43 x 8.5 cm (18 x 17 x 3 in.)
Weight
Chiller
MRU Air Recirculator
11 kg (25 lbs.)
9 kg (20 lbs.)
1 At 800 nm
2 Average…

COHR ChameleonVision-S DS 0517 3.pdf

COHR ChameleonVision-S DS 0517 3.pdf

…Dimensions (L x W x H)
Chiller 436 x 270 x 393 mm (17.17 x 10.63 x 15.47 in.)
MRU Air Recirculator 46 x 43 x 8.5 cm (18 x 17 x 3 in.)
Weight
Chiller 11 kg (25 lbs.)
MRU Air Recirculator: 9 kg (20 lbs.)
1 At 800 nm
2 Average speed measured over entire tuning range.…

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

…to >3W)
· Ultra wide dispersion compensation
range from 0 to >47,000 fs2
· Tuning above 920 nm provided by
MRU air recirculator (included)
· Simple menu-driven GUI or RS-232
operator interface for laser and
precompensation features
· PowerTrackTM active…

COHR AzureNX 266 1000 DS 0618 3.pdf

COHR AzureNX 266 1000 DS 0618 3.pdf

…20 to 33°C
COOLING REQUIREMENTS
Laser Head Water-cooled, closed loop chiller for laser head
Power Supply Air-cooled
Recirculator Unit Water-cooled
Shipping Requirements 0 to 55°C in non-condensing environment
Orientation Horizontal ±2°
1 Defined as time…

COHR Azure DS 0717 4.pdf

COHR Azure DS 0717 4.pdf

…lbs.)
Chiller
Dimensions (L x W x H) 436 x 210 x 393 mm (17.2 x 8.3 x 15.5 in.)
Weight 17.5 kg (38.6 lbs.)
MRU (Miniature Recirculator Unit)
Dimensions (L x W x H) 451 x 479 x 95 mm (17.8 x 18.9 x 3.7 in.)
Weight 10.0 kg (26.5 lbs.)
Operating Thermal Requirements…

Biosafety Level 3 setup for multiphoton microscopy in vivo

Biosafety Level 3 setup for multiphoton microscopy in vivo

…rate is critical to maintain the temperature of the laser components
according to the manufacturer's specifications. Both BSCs have an opening in the back panel to allow the passage of the cables connecting the laser head to the power supply, chiller and miniature recirculator unit (MRU)

00 Laser Cooling.book

00 Laser Cooling.book

Water Cooling Guidelines
11
Closed-Loop
Heat Exchanger
Closed-loop systems involve constantly recirculating a fixed
volume of water through the laser. This offers important advantages:
the laser cooling water can be easily monitored and treated to give it