Reference Cavity

INNOVA 300C Laser

INNOVA 300C Laser

…pumping configuration
* Argon or Krypton models, including Krypton models optimized for Violet or UV wavelengths
* PowerTrack™ automatic active cavity stabilization for maximum power, best transverse mode, and lowest beam noise
* ModeTrack/ModeTune™ etalon stabilization for mode-hop-free,…

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

"reference" cavity and use the
"analyzer" cavity to monitor any residual changes in the Verdi wavelength.
Figure 1. The wavelength of a Verdi with a PZT-actuated mirror was locked to the reference cavity.
Stabilization of the Verdi wavelength was verified using the analyzer cavity.

Photonics Spectra - August 2018

Photonics Spectra - August 2018

…the cavity, with a precision and stability
of ±1 MHz. They actually use the cavity
itself as a reference for locking the laser.
Only low (<1 W) laser power is needed for
this method because the high numerical
aperture (NA) creates very high intensity
at the cavity

Chameleon Reliability Antarctia Final WP.pdf

Chameleon Reliability Antarctia Final WP.pdf

…on a very few
components and the optics are solder-bonded on submounts that are also solder-bonded on the optical
reference baseplate for perfect cavity alignment. There
are no locking or threaded elements or flexure points.
Alignment of each optic during bonding is monitored…

Mira brochure

Mira brochure


900 option offers automatic cavity-length control. Length actuators are used to lock the cavity
repetition rate to an internal crystal oscillator or
to an external reference frequency. Computer
control allows `one touch' lock acquisition.
Mira OPO.
The Mira…

Sapphire-Advantage-Low-Noise.pdf

Sapphire-Advantage-Low-Noise.pdf

…timescale of the cavity
round trip time. Thus, on the laser mode timescale
there is no stored gain, only instantaneous gain. The
behavior of the individual cavity modes therefore is
determined solely by the cavity, the gain just follows
along.
If the cavity is properly…

Innova Sabre brochure

Innova Sabre brochure

…power. And -Track provides fast
warm-up and maintains cavity length to assure
long-term stability.
If you wish to maintain an absolute
frequency, Sabre can be locked to an external
frequency reference.
UV Performance You Can See
With Sabre's intelligent…

Preinstallation Manual Astrella Ultrafast Amplifier Laser System

Preinstallation Manual Astrella Ultrafast Amplifier Laser System

…and Revolution modules. Refer to the Vitara and Revolution
Operator's Manuals for additional information.
Water Chiller The closed-loop water chiller dissipates the heat generated by the
system and stabilizes the Vitara, Revolution, and amplifier cavity.
The temperature is set…

Vitara Preinstall.book

Vitara Preinstall.book

…low
noise and high performance pump laser. The compact cavity design
employs intracavity second harmonic generation to produce green
(532 nm) visible light output, key for ultrafast Ti:Sapphire pumping
(refer to Figure 2-2). OPSL technology offers many advantages
inherited…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…with the Vitesse
and Chameleon. Similarly, the Pulse Switch is compatible with the Mira-900, but incompatible with
the Mira-HP. Please refer to the specifications on the
individual product pages and the accessory compatibility charts on page 83 for more details. If you still have

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…incompatible with the Chameleon.
Similarly, the Pulse Switch is compatible with the
Mira-900, but incompatible with the Mira-HP. Please
refer to the specifications on the individual product
pages and the accessory compatibility charts on page
81 for more details. If you…

mephisto MOPA whitepaper v05.pdf

mephisto MOPA whitepaper v05.pdf

…experiments. This control also enables locking the laser to an external references when even
higher frequency stability is needed. For example, the user may wish to lock the laser to an
external high-stability cavity or iodine line by having access to frequency control of the laser.

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.