Ask a Question
Coherent
Search Results
Refine
1 - 12 of 92 Products for 'Reference Cavity' Page 1 of 8 |

Reference Cavity

COHR MBRseries DS 0317 3 FINAL.pdf

COHR MBRseries DS 0317 3 FINAL.pdf

…(with 18W pump), wide tuning range of 700 nm to 1030 nm, 30 GHz scan range and an integrated stabilized reference cavity. This temperature-controlled, hermetically sealed cavity provides reference for laser emission frequency stabilization against external temperature and rapid air pressure changes.…

Mira brochure

Mira brochure

…Synchro-LockTM 900 option offers automatic cavity-length control. Length actuators are used to lock the cavity repetition rate to an internal crystal oscillator or to an external reference frequency. Computer control allows `one touch' lock acquisition. Mira OPO. The Mira OPO, a synchronously-pumped…

MBR110 DS

MBR110 DS

…Coherent representative if an alternative configuration is proposed. 2 Measured at the peak of the tuning curve. 3 Measured relative to the reference cavity with 1W output power at 780 nm. 4 At output window. 5 Measured 10 Hz to 10 MHz bandwidth (using Verdi pump). Typical MBR Tuning Curves with…

INNOVA 300C

INNOVA 300C

…pumping configuration
* Argon or Krypton models, including Krypton models optimized for Violet or UV wavelengths
* PowerTrack™ automatic active cavity stabilization for maximum power, best transverse mode, and lowest beam noise
* ModeTrack/ModeTune™ etalon stabilization for mode-hop-free,…

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

Microsoft Word - Wavelength Control and Locking with Sub-MHz Precision

reference cavity. The light reflected back from this cavity contained information about the relative difference between the Verdi wavelength and the wavelength of the reference cavity. A Haensch-Couillaud scheme was used to lock the Verdi wavelength to the fixed wavelength of the reference cavity.

MBR110 DS

MBR110 DS

…diode · Powered by VerdiTM · Birefringent filter · Single thin etalon · Galvonometer mounted tilting Brewster plates · Piezo mounted mirror · Reference cavity · Electronic etalon lock Superior Reliability & Performance Optical Schematic of the MBR-110 Ti:Sapphire Laser Verdi 532 nm input Pump…

MBR110 DS

MBR110 DS

…diode · Powered by VerdiTM · Birefringent filter · Single thin etalon · Galvonometer mounted tilting Brewster plates · Piezo mounted mirror · Reference cavity · Electronic etalon lock Superior Reliability & Performance Optical Schematic of the MBR-110 Ti:Sapphire Laser Verdi 532 nm input Pump…

MBR110 DS

MBR110 DS

…diode · Powered by VerdiTM · Birefringent filter · Single thin etalon · Galvonometer mounted tilting Brewster plates · Piezo mounted mirror · Reference cavity · Electronic etalon lock Superior Reliability & Performance Optical Schematic of the MBR-110 Ti:Sapphire Laser Verdi 532 nm input Pump…

COHR MBRseries DS 0317 3 FINAL.pdf

COHR MBRseries DS 0317 3 FINAL.pdf

…Output Coupler M4 Photodiodes Laser Output Beamsplitter Mirror Reference CavityPiezo Mirror M3 SPECIFICATIONS MBR 110 MBR PS MBR EL MBR PE MBR 01 Birefringent Filter · · · · · Thin Etalon · · · · Dual Brewster Plates · · Reference Cavity · Electronic Etalon Lock · · · Electronic Wavelength Scanning…

COHR MBRseries DS 0317 3 FINAL.pdf

COHR MBRseries DS 0317 3 FINAL.pdf

…Output Coupler M4 Photodiodes Laser Output Beamsplitter Mirror Reference CavityPiezo Mirror M3 SPECIFICATIONS MBR 110 MBR PS MBR EL MBR PE MBR 01 Birefringent Filter · · · · · Thin Etalon · · · · Dual Brewster Plates · · Reference Cavity · Electronic Etalon Lock · · · Electronic Wavelength Scanning…

COHR MBRseries DS 0317 3 FINAL.pdf

COHR MBRseries DS 0317 3 FINAL.pdf

…(with 18W pump), wide tuning range of 700 nm to 1030 nm, 30 GHz scan range and an integrated stabilized reference cavity. This temperature-controlled, hermetically sealed cavity provides reference for laser emission frequency stabilization against external temperature and rapid air pressure changes.…

MBR110 DS

MBR110 DS

…Coherent representative if an alternative configuration is proposed. 2 Measured at the peak of the tuning curve. 3 Measured relative to the reference cavity with 1W output power at 780 nm. 4 At output window. 5 Measured 10 Hz to 10 MHz bandwidth (using Verdi pump). Typical MBR Tuning Curves with…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions