Ask a Question
Coherent
Search Results
Refine
1 - 12 of 52 Products for 'Rf Generator' Page 1 of 5 |

Rf Generator

Book.book

Book.book

…K ohm. The laser SMB connector has an input impedance of 50 ohm.. 1. Connect the laser as shown in "Section Three: Installation" (p. 3-1). 2. Connect a signal generator cable (impedance Z = 50 ) between the laser head and the RF-source (maximum frequency < 150 MHz). Figure 5-1. Pulse Timing Diagrams

Diamond g50 100 Quiksetup.pdf

Diamond g50 100 Quiksetup.pdf

…il Manuale OEM del laser G-50/100. DESCRIZIONE Il modello G-50/100 e' un dispositivo OEM composto da un resonatore laser ed un generatore di Radiofrequenza (RF) integrati. Come ingressi sono richiesti 48 VDC, acqua di raffreddamento e vari segnali di controllo. STANDARD DI SICUREZZA Il modello…

00 E-250 Pre.book

00 E-250 Pre.book

Control Interfaces 4 - 7 Drive Circuit for RF Power Supply An example of a drive circuit to interface to the ENABLE and MODULATION inputs is shown in Figure 4-4. The MODULATION input interface shown in Figure 4-3 is designed to be driven by a differential line driver meeting the requirements of EIA…

Pulse Switch for Mira 900

Pulse Switch for Mira 900

generation option provides conversion efficiencies up to 40% May be purged for tuning above 920 nm Control box (supplied) includes: Internal frequency divider (1:2 to 260,000) External trigger input (TTL) Digital and analog phase adjust of RF pulse (360°) Electronic delay Synchronization and RF

Diamond g50 100 Quiksetup.pdf

Diamond g50 100 Quiksetup.pdf

…il Manuale OEM del laser G-50/100. DESCRIZIONE Il modello G-50/100 e' un dispositivo OEM composto da un resonatore laser ed un generatore di Radiofrequenza (RF) integrati. Come ingressi sono richiesti 48 VDC, acqua di raffreddamento e vari segnali di controllo. STANDARD DI SICUREZZA Il modello…

Diamond g50 100 Quiksetup.pdf

Diamond g50 100 Quiksetup.pdf

…il Manuale OEM del laser G-50/100. DESCRIZIONE Il modello G-50/100 e' un dispositivo OEM composto da un resonatore laser ed un generatore di Radiofrequenza (RF) integrati. Come ingressi sono richiesti 48 VDC, acqua di raffreddamento e vari segnali di controllo. STANDARD DI SICUREZZA Il modello…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual 4 - 8 Drive Circuit for RF Power Module An example of a drive circuit to interface to the ENABLE and MODULATION inputs is shown in Figure 4-4. The MODULATION input interface shown in Figure 4-4 is designed to be driven by a differential line…

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual 4 - 8 Drive Circuit for RF Power Module An example of a drive circuit to interface to the ENABLE and MODULATION inputs is shown in Figure 4-4. The MODULATION input interface shown in Figure 4-4 is designed to be driven by a differential line…

00 E-250 Pre.book

00 E-250 Pre.book

Control Interfaces 4 - 7 Drive Circuit for RF Power Supply An example of a drive circuit to interface to the ENABLE and MODULATION inputs is shown in Figure 4-4. The MODULATION input interface shown in Figure 4-3 is designed to be driven by a differential line driver meeting the requirements of EIA…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual 4 - 8 Drive Circuit for RF Power Module An example of a drive circuit to interface to the ENABLE and MODULATION inputs is shown in Figure 4-4. The MODULATION input interface shown in Figure 4-4 is designed to be driven by a differential line…

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual 4 - 8 Drive Circuit for RF Power Module An example of a drive circuit to interface to the ENABLE and MODULATION inputs is shown in Figure 4-4. The MODULATION input interface shown in Figure 4-4 is designed to be driven by a differential line…

00 E-250 Pre.book

00 E-250 Pre.book

Control Interfaces 4 - 7 Drive Circuit for RF Power Supply An example of a drive circuit to interface to the ENABLE and MODULATION inputs is shown in Figure 4-4. The MODULATION input interface shown in Figure 4-3 is designed to be driven by a differential line driver meeting the requirements of EIA…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.