Sabre Heat Exchanger

00 Sabre Preinstall.book

00 Sabre Preinstall.book

…water heat exchanger can be either tap
water or any closed loop water cooling system. The requirements for
the plant water are illustrated in Figure 2.
It is important to note that the minimum temperature delta between
the plant side of the Innova Sabre ion laser's heat exchanger

INNOVA Sabre Laser

INNOVA Sabre Laser

…hand, not the laser. Additionally, the Sabre provides exquisite single-frequency performance with ν-Track™ active cavity length stabilization, for stable performance within minutes. On top of our tangential-flow magnet and integral water-to-water heat exchanger for lowest induced jitter, you are…

Innova Sabre brochure

Innova Sabre brochure


tubes that prevent anode window
deterioration - the second major
cause of tube failures. Even
optimized cooling-water from
Sabre's heat exchanger
helps increase tube life.
So plasma tube
replacement intervals are stretched by
thousands of hours.

Sabre MotoFred MC-031

Sabre MotoFred MC-031

…(44")
31.98 cm
(12.59")
254.41 cm
(100.16")
74.70 cm
(29.41")
.1.85 cm
(73")
HEAT EXCHANGER
POWER SUPPLY
HEAT EXCHANGER
POWER SUPPLY
+.38
-.12
+0.97
-0.30
+.38
-.12
+0.97
-0.30
20.32 cm

00 Laser Cooling.book

00 Laser Cooling.book

…Small Frame Heat exchanger weights and Dimensions are given
in Table 10.
Sabre Heat
Exchanger
All Sabre laser systems include an integral Heat Exchanger which is
powered and controlled by the Sabre power supply via an interface
cable. Please refer to the Sabre Operators…

00 SabreMFreD Preinstall.book

00 SabreMFreD Preinstall.book

…The facility outlet must have a fuse or circuit
breaker on each phase. Consult applicable local electrical codes to
select this hardware.
Figure 1. Innova Sabre MotoFRED Ion Laser System
HEAT
EXCHANGER
POWER
SUPPLY
REMOTE CONTROL MODULE
LASER HEAD

UCLD Catalog.book

UCLD Catalog.book

…Topics: Fault message troubleshooting to the major assembly level, including reintegration of the
faulty assembly (head, power supply, heat exchanger, and remote), available upon advance request.
Prerequisites: Some prior working experience with lasers, laser theory, and general laboratory…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions