Search Results

13 - 24 of 43 Products for 'Safety Shutter' Page 2 of 4 |

Safety Shutter

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

…laser safety purpose only.
This shutter is not to be used for beam modulation (as a `process
shutter').
Table 4-7. Extended Interface Signal Descriptions
IDENTIFICATION BRIEF DESCRIPTION CONNECTION
INPUT SIGNALS
Shutter Command
Opens and closes shutter (if shutter

Diamond J-2 Series OEM Lasers Preinstallation Manual, Rev. AB

…laser safety purpose only.
This shutter is not to be used for beam modulation (as a `process
shutter').
Table 4-7. Extended Interface Signal Descriptions
IDENTIFICATION BRIEF DESCRIPTION CONNECTION
INPUT SIGNALS
Shutter Command
Opens and closes shutter (if shutter

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

Diamond J-3 Series OEM Lasers Preinstallation Manual, Rev. AC

…laser safety purpose only.
This shutter is not to be used for beam modulation (as a `process
shutter').
Table 4-7. Extended Interface Signal Descriptions
IDENTIFICATION BRIEF DESCRIPTION CONNECTION
INPUT SIGNALS
Shutter Command
Opens and closes shutter (if shutter

COHR THzSpectroscopyBrochure 0219 2.pdf

COHR THzSpectroscopyBrochure 0219 2.pdf

…tip/tilt probe mount. The Vial/Tablet Sample Holder incorporates an adjustable steering
mirror, interchangeable focusing lens, and safety shutter, and the Steerable Non-contact Optic Mount allows for projection and
steering of the output beam with precision alignment and interchangeable…

00 E-1000 PreInst.book

00 E-1000 PreInst.book

…facility appoint and train a Laser
Safety Officer (LSO) responsible for overseeing all aspects of laser
safety.
Design systems with safety in mind. Use engineering controls such
as: enclosed beam paths, interlocked covers, and safety shutters.
Designate a laser controlled…

COHR DiamondFLC DS 0318 4.pdf

COHR DiamondFLC DS 0318 4.pdf


Communication via RS-232 interface
Laser control via TTL signal (gate)
Power control RS-232 or analog input (0 to 10 V)
Safety shutter according to DIN EN 13849-1
1 Other beam diameters available on request.
2 Other wavelengths available upon request.
3 Other fiber…

COHR StarFiber DS 0218 6.pdf

COHR StarFiber DS 0218 6.pdf

…x 22.65 x 43.86 in.)
STANDARDIZED INTERFACES
Parameter set via 24 V parallel I/O, communication via Ethernet, analog (0-10 V)
Safety shutter according to DIN EN 13849-1
OPTIONS
- Application packages:
· Fine welding with scanner or fixed optics
· Fine cutting with…

COHR OBISfamily DS 0818 8.pdf

COHR OBISfamily DS 0818 8.pdf

…peak-to-peak; line regulation <0.5%.
MECHANICAL SPECIFICATIONS
OBIS LX/LS
38 mm
(1.5 in.)
Status
Indicator
Safety
Shutter
Laser Exit Aperture
M6 X 0.75 Thread
2.54 mm Deep
OEM Label
Fan
USB
SDR
Power
40 mm

COHR StarFiber DS 0319 1.pdf

COHR StarFiber DS 0319 1.pdf

…x 22.65 x 43.86 in.)
STANDARDIZED INTERFACES
Parameter set via 24 V parallel I/O, communication via Ethernet, analog (0-10 V)
Safety shutter according to DIN EN 13849-1
OPTIONS
- Application packages:
· Fine welding with scanner or fixed optics
· Fine cutting with…

COHR OBISfamily DS 0719 2.pdf

COHR OBISfamily DS 0719 2.pdf

…peak-to-peak; line regulation <0.5%.
MECHANICAL SPECIFICATIONS
OBIS LX/LS
38 mm
(1.5 in.)
Status
Indicator
Safety
Shutter
Laser Exit Aperture
M6 X 0.75 Thread
2.54 mm Deep
OEM Label
Fan
USB
SDR
Power
40 mm

COHR OBISfamily DS 0119 3.pdf

COHR OBISfamily DS 0119 3.pdf

…peak-to-peak; line regulation <0.5%.
MECHANICAL SPECIFICATIONS
OBIS LX/LS
38 mm
(1.5 in.)
Status
Indicator
Safety
Shutter
Laser Exit Aperture
M6 X 0.75 Thread
2.54 mm Deep
OEM Label
Fan
USB
SDR
Power
40 mm

00 E-400 E-1000 Series Preinstall.book

00 E-400 E-1000 Series Preinstall.book

…facility appoint and train a Laser
Safety Officer (LSO) responsible for overseeing all aspects of laser
safety.
Design systems with safety in mind. Use engineering controls such
as: enclosed beam paths, interlocked covers, and safety shutters.
Designate a laser controlled…