... . The Vector laser produced 3W of output at 1064 nm, at a pulse repetition rate of 30 kHz. The beam was then delivered through a Scanlab HurryScan 14 scanhead and focused with a 160 mm focal length f theta scan lens. The theoretical spot size for this configuration is 22 µm. Scaps Sam 2D software was ...
... polarization of the beam on the target. The set-up for this scanner system is shown in Figure 1. For drilling precise circular holes the scanner head is replaced with a trepanning system as shown in Figure 2. The main parts of a trepanning system are rotating wedges to shift the laser beam. By rotating ... Related Searches:trepanning head | highlights | fiber optic taper | pulse laser
... marks because they can be focused to small spot sizes. Scanning system A typical card marking system utilizes two galvanometer mounted mirrors and a scan lens to enable processing over a two dimensional field as large as 130 x 130 mm, with a resolution of up to 650 dpi. Because the laser is pulsed, ... Related Searches:direct modulation
ModeMaster PC ScanHead Modular Components Components for Other Wavelength and Divergence Ranges Allow quick changes to other wavelengths or divergences to suit your needs. Superior Reliability & Performance Lasers and Laser-based Systems Laser Measurement and Control Precision Optics Related Accessories ... Related Searches:modemaster | modemaster pc
ModeMaster PC ScanHead Modular Components Components for Other Wavelength and Divergence Ranges Allow quick changes to other wavelengths or divergences to suit your needs. Sales Support: 1-800-343-4912 NEW! Smart Finder Tool Search by Sensors and/or Meters. -- select product type -- Find ... Related Searches:modemaster
... . Another practical difference between the Matrix IR and fiber lasers involves optical compatibility between the laser and the commercial scanning heads used in marking systems. Today's high-performance, self-contained scanheads are based on lightweight galvanometer mirrors that provide high-speed, ...
... laser beam was passed through a 3X beam expander. The beam was then focused on the sapphire substrate surface with a 160-mm focal length f-theta scan lens in a galvanometer scanner assembly. Focal spot size was approximately 12 µm. The laser was operated at a 20 kHz repetition rate near its maximum ... Related Searches:sapphire scribing | laser scribing | sapphire | scribing
... Mira Mira Optima 900 Mira Optima 900-D (Femto + Pico) Mira Optima 900-F Mira Optima 900-P Mira-HP Mira-OPO Mira-S Mirror Set Only ModeMaster PC ScanHead Modular Components Mount
Related Searches:mira | modemaster | pico | coherent mira 900
... polarization of the beam on the target. The set-up for this scanner system is shown in Figure 1. For drilling precise circular holes the scanner head is replaced with a trepanning system as shown in Figure 2. The main parts of a trepanning system are rotating wedges to shift the laser beam. By rotating ... Related Searches:trepanning head
... stability characteristics in both the short term (i.e., noise) and long term (i.e., drift). Another advantage is factory sealing of the laser head. Specifically, the mounts contain no organics or other materials that could slowly outgas and require cleaning or replacement of the optics. These mounts ...