Search Results

Refine

Result Type

1 - 12 of 21 Products for 'Scan Mirror' Page 1 of 2 |

Scan Mirror

Coherent Whitepaper 3D Marking.pdf

Coherent Whitepaper 3D Marking.pdf

…Basic optical elements of a typical scanning system for laser marking or ablation. For simplicity, only one
of the two scan mirrors is shown.
From the standpoint of the optics, there is one major limitation to this approach. This is that most
scan lenses are designed to cover a "flat…

ModeMaster PC User Manual

ModeMaster PC User Manual

Getting Started
1 - 3
3. Rotate alignment mirror assembly back and remove red dust
cover and protective foam plug.
ModeMaster
Scan Head
Locking
Knob
Alignment
Mirror Assembly
Support Column
Safety Stop Ring
5.5"
Minimum

CMM 10.4.indd

CMM 10.4.indd

…the laser is directed
through a pair of galvanometer scan mirrors and
then a scan lens which focuses it to a spot size
in the 10 to 20 microns range on the surface of
the OLED. Because the field of view of the scan
lens is relatively limited - typically a few hundred

COHR WhitePaper High Repetition Rate USP Lasers Improve OLED Cutting Results.pdf

COHR WhitePaper High Repetition Rate USP Lasers Improve OLED Cutting Results.pdf

…the laser beam is directed through a pair of galvanometer scan
mirrors and then a scan lens which focuses it to a spot size in the 10 to 20 µm range on the
surface of the OLED. Because the field of view of the scan lens is relatively limited - typically a
few hundred millimeters…

Industrial Photonics - July 2018

Industrial Photonics - July 2018

…wavelengths in the visible and IR. But,
again, heat builds up and fast scanning or parallel processing is often beneficial.
Thus, systems that provide fast and high-accuracy
scanning using galvanometer mirror and stage combinations could be significant for micromachining, Sercel

Industrial Laser Solutions - November/December 2015

Industrial Laser Solutions - November/December 2015

…curved surface of a pill
bottle (FIGURE 1). The 355 nm laser, working with a focused spot size of 30µm, was
scanned over the part surface using a galvanometer mirror system. In this configuration, high-contrast, 8 × 8mm barcode patterns were generated in 2s.
The MATRIX 355 is…

Bio Photonics - April 2015

Bio Photonics - April 2015

…Principles of STED: (a) Schematic drawing of the setup of a STED nanoscope with phase plate, objective lens dichroic mirror (DC), fluorescence filter (F), detector, scanning device, and excitation and STED lasers with their focal intensity distribution (right) and a representative,…

115-80020 Notes Spectral meas...

115-80020 Notes Spectral meas...

…left and right).
Figure 3 shows a single line (50MHz linewidth) at each Free Spectral range (FSR) of the FabryPerot analyzer. The Fabry-Perot scanned through four FSR in the graphs. Figure 3 left and
right are indifferentiable whereas the OSA measurement in figure 1 shows a mode structure…

Photonics Spectra - June 2017

Photonics Spectra - June 2017

…1. Principles of STED. Schematic drawing of the setup of a STED nanoscope with phase plate, objective lens dichroic mirror, fluorescence filter, detector, scanning device, and excitation and STED lasers with their focal intensity distribution (right), and a representative, subdiffraction-sized…

Innova Sabre brochure

Innova Sabre brochure


to cavity alignment, PowerTrack automatically keeps the mirrors perfectly aligned
for maximum power, stability, and handsoff operation.
Ion Laser Gain
ModeTune finds the peak of the gain curve
by scanning the etalon temperature while
locking the cavity length to…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…5-axis head mount and beam position display of the ModeMaster PC provide easy angular alignment and
translational centering of the lens and scan axis to the beam propagation path.
Beam diameter is a critical parameter in beam propagation measurements. Second-moment diameters (D4) give…

Coherent Whitepaper - Astrella Tisch Sphere FINAL.pdf

Coherent Whitepaper - Astrella Tisch Sphere FINAL.pdf

…into an amplitude signal that can be sensed on a photodetector
array. The d-scan modules tailored for an HCF system comprises a chirped mirror compressor
including a pair of thin glass wedges on translation stages, providing both positive and negative
dispersion. After the pulses…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions