1 - 12 of 139 Products for 'Shg Thg' Page 1 of 12 |

Shg Thg

Picosecond laser

Picosecond laser

…125 µJ 200-1000 IR, SHG, THG AOM Hyper Rapid 50 50 W 125 µJ 400-1000 IR, SHG, THG AOM Hyper Rapid 50-HE (high energy) 50 W 200 µJ 200-500 specified; up to 1000 IR, SHG, THG AOM Hyper Rapid 75 75 W 150 µJ 400-1000 IR, SHG, THG AOM Hyper Rapid 100 100 W 250 µJ 400-1000 IR, SHG, THG AOM 5 of 27 HYPER…

Picosecond laser

Picosecond laser

…125 µJ 200-1000 IR, SHG, THG AOM Hyper Rapid 50 50 W 125 µJ 400-1000 IR, SHG, THG AOM Hyper Rapid 50-HE (high energy) 50 W 200 µJ 200-500 specified; up to 1000 IR, SHG, THG AOM Hyper Rapid 75 75 W 150 µJ 400-1000 IR, SHG, THG AOM Hyper Rapid 100 100 W 250 µJ 400-1000 IR, SHG, THG AOM 5 of 27 HYPER…

Picosecond laser

Picosecond laser

…Rapid 6 W 40 µJ 10-1000 IR, SHG, THG EOM Rapid 10 10 W 60 µJ 10-1000 optimization range: 100-500 or 400-1000 IR, SHG, THG not required, function is integrated Hyper Rapid 25 25 W 125 µJ 200-1000 IR, SHG, THG EOM Hyper Rapid 50 50 W 125 µJ 400-1000 IR, SHG, THG EOM Hyper Rapid 50-HE (high energy)…

Harmonic Generator

Harmonic Generator

…and SHG spatial separation and recombination. Key Advantages
* Magnetically indexed crystals simplifies SHG/THG/FHG conversion
* Walk-off compensator maintains good beam circularity
* Delay compensator for simple inline THG generation
* Easily upgradable
* Autotracker option for SHG and THG.

Chameleon Discovery w/ Total Power Control

Chameleon Discovery w/ Total Power Control

…ongoing developments in RFPs and red-shifted calcium indicators. High peak power ensures optimized performance for label-free techniques such as SHG and THG. A high power (3.5 W at 1040 nm), secondary output further allows simultaneous, multi-wavelength excitation of multiple fluorescent markers or…

Paladin

Paladin

…Fully controlled light-loop operation for highest power stability and low noise
* Exquisite and stable beam quality due to pre-qualified spots on THG crystal and automated SHG/THG optimization including crystal shifting
* Cleanroom-manufactured using PermAlign solder-bonded optics for best…

Chameleon VUE Harmonics Accessory

Chameleon VUE Harmonics Accessory

…to automatically optimize crystal phase matching as the wavelength of the pump laser varies.
* VUE SHG is a second harmonic generation system, which can cover 340 nm to 540 nm.
* VUE THG is a third harmonic generation system, spanning 227 nm to 540 nm. The modular instrument design is purpose-built…

Picosecond laser

Picosecond laser

…Rapid 6 W 40 µJ 10-1000 IR, SHG, THG EOM Rapid 10 10 W 60 µJ 10-1000 optimization range: 100-500 or 400-1000 IR, SHG, THG not required, function is integrated Hyper Rapid 25 25 W 125 µJ 200-1000 IR, SHG, THG EOM Hyper Rapid 50 50 W 125 µJ 400-1000 IR, SHG, THG EOM Hyper Rapid 50-HE (high energy)…

Picosecond laser

Picosecond laser

…Rapid 6 W 40 µJ 10-1000 IR, SHG, THG EOM Rapid 10 10 W 60 µJ 10-1000 optimization range: 100-500 or 400-1000 IR, SHG, THG not required, function is integrated Hyper Rapid 25 25 W 125 µJ 200-1000 IR, SHG, THG EOM Hyper Rapid 50 50 W 125 µJ 400-1000 IR, SHG, THG EOM Hyper Rapid 50-HE (high energy)…

Picosecond laser

Picosecond laser

…125 µJ 200-1000 IR, SHG, THG AOM Hyper Rapid 50 50 W 125 µJ 400-1000 IR, SHG, THG AOM Hyper Rapid 50-HE (high energy) 50 W 200 µJ 200-500 specified; up to 1000 IR, SHG, THG AOM Hyper Rapid 75 75 W 150 µJ 400-1000 IR, SHG, THG AOM Hyper Rapid 100 100 W 250 µJ 400-1000 IR, SHG, THG AOM 5 of 27 HYPER…

LegendEliteSeries DS

LegendEliteSeries DS

…· Delay compensator for simple in-line THG generation · Easily upgradable · Compact footprint · Autotracker option for SHG and THG. Provides automatic phase matching optimization as input wavelength is changed. 385 mm (15.16 in.)27 mm (1.07 in.) SHG only 286mm(11.26in.) 103 mm to 134 mm (4.0…

LegendEliteSeries DS

LegendEliteSeries DS

…· Delay compensator for simple in-line THG generation · Easily upgradable · Compact footprint · Autotracker option for SHG and THG. Provides automatic phase matching optimization as input wavelength is changed. 385 mm (15.16 in.)27 mm (1.07 in.) SHG only 286mm(11.26in.) 103 mm to 134 mm (4.0…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.