Search Results

1 - 12 of 32 Products for 'Spectrum Analyzer' Page 1 of 3 |
Related Categories: Ecl | Power Meter Pm10 | 790 Nm | 652 | Ondax

Spectrum Analyzer

115-80020 Notes Spectral meas...

115-80020 Notes Spectral meas...

…is a more reliable method to determine linewidth. A linewidth of less than 50 MHz is consistently obtained using the FPsystem. Fabry-Perot Analyzer (Thorlabs SA200-6A) Optical Spectrum Analyzer (Ando AQ6315A) Beam-splitter Ondax TO-can wavelength stabilized laser Figure 1: Set-up Page 1 of 2

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…BeamView Analyzer
systems are the recognized leader
in software, hardware and optical components for laser beam
analysis. Constant product improvement based on customer feedback,
and innovation from beam analysis
experts, have made BeamView
Analyzer products the…

SureLock™ LM Series/Compact Laser Modules

SureLock™ LM Series/Compact Laser Modules

…Modules Coherent’s LM Series Compact Laser Modules incorporate the SureLock VHG-stabilized laser diode to deliver steady, single frequency or spectrum narrowed performance in an ultra-compact footprint. Offering both computer and integrated user controls, the LM Series includes precision temperature…

115-80019 spectral output 640 658 685 785

115-80019 spectral output 640 658 685 785

…lineshape of the family of wavelength stabilized TO-can lasers is measured with a
high sensitivity double spectrometer on an ANDO Optical Spectrum Analyzer (ModelAQ6315A).
The resolution of the spectrometer is 0.05 nm for all scans.
The spectral lineshape of the wavelength stabilized…

115-80008-016-785nm wavelength power linewidth data

115-80008-016-785nm wavelength power linewidth data

…The laser diode is run in constant current mode. Figure 2 shows the spectrum, measured with an OSA, exhibiting > 45 dB of Side Mode Suppression. Figure 3 shows the linewidth measured with a Fabry-Perot spectrum analyzer with 1.5 GHz free Spectral range and 7.5 MHz resolution. Figure 1 Figure…

115-80021-001 785 nm reliabil...

115-80021-001 785 nm reliabil...

…of 60 degrees Celsius for up to 5,471 hours. Figure 1 ,2 and 3 show the wavelength versus temperature measured with an ANDO AQ-6315A Optical Spectrum Analyzer (OSA). After 5,471 hours of operation at full power and elevated temperature, the temperature range over which the laser diode is wavelength…

High Power 7-GHz Bandwidth External-Cavity Diode Laser Array and Its Use in Optically Pumping Singlet Delta Oxygen.pdf

High Power 7-GHz Bandwidth External-Cavity Diode Laser Array and Its Use in Optically Pumping Singlet Delta Oxygen.pdf

…sphere was used to collect all the light and an optical fiber couples the integrating
sphere output into an optical spectrum analyzer (OSA). The OSA measures the spectrum as
shown in Fig. 2(a).
750 752 754 756 758 760 762 764 766 768
-85
-80
-75
-70
-65

00 SabreMFreD Preinstall.book

00 SabreMFreD Preinstall.book

…intense to
cause severe eye damage.
For more precise measurements, a beam scanner, spectrum analyzer
or M2 meter such as the Coherent ModeMasterTM Beam Propagation
Analyzer can be used. Contact Coherent Technical Support at
800-367-7890 for more information on how…

00 Sabre Preinstall.book

00 Sabre Preinstall.book

…intense to
cause severe eye damage.
For more precise measurements, a beam scanner, spectrum analyzer
or M2 meter such as the Coherent ModeMasterTM Beam Propagation
Analyzer can be used. Contact Coherent Technical Support at
800-367-7890 for more information on how…

Sample manuscript showing specifications and style

Sample manuscript showing specifications and style

…wavelength configuration.
Figure 2(b) shows the single frequency spectrum for three rotation angles of the VHG. The laser single frequency
operation was verified by the spectrum obtained with an optical spectrum analyzer with 10 pm resolution. The linewidth
was not measured. The diode…

Self-Aligned Non-Dispersive External Cavity Tunable Laser.pdf

Self-Aligned Non-Dispersive External Cavity Tunable Laser.pdf

…wavelength configuration.
Figure 2(b) shows the single frequency spectrum for three rotation angles of the VHG. The
laser single frequency operation was verified by the spectrum obtained with an optical
spectrum analyzer with 10 pm resolution. The linewidth was not measured. The diode…

eLP11-02-56  Coherent

eLP11-02-56 Coherent

…variations in
LED output spectrum and spatial illumination distribution. This presents a serious
challenge to achieving instrument consistency and serviceability.
Optimized Lasers
Of course, the choice of a laser as the light