Search Results

Refine
1 - 12 of 12 Products for 'Sync Out' Page 1 of 1 |
  • 1

Sync Out

Picosecond laser

Picosecond laser

1 Pre-Installation Guide May 2016
11 Sync IN: BNC plug, connected to Sync A (power supply, rear side)
12 Sync OUT: BNC plug, output TTL signal for synchronizing
13 RFSA: spectral analysis of the seeder laser
USER signals
Signal Direction Location Type Description
GATE…

ModeMaster Modular Components

ModeMaster Modular Components

…signal out, 1 to 5V pulse Trigger (syncs to drum rotation), 0 to 5V pulse Detector signal outpur, 0 to 13V maximum A/D contorl signal out, 1 to 5V pulse Trigger (syncs to drum rotation), 0 to 5V pulse Detector signal outpur, 0 to 13V maximum A/D contorl signal out, 1 to 5V pulse Trigger (syncs to…

ModeMaster PC M-Squared

ModeMaster PC M-Squared

…Control signal out, 0-5V pulse. Trigger (syncs to drum rotation), 0-5V pulse. Detector signal output, 0-13V maximum. A/D Control signal out, 0-5V pulse. Trigger (syncs to drum rotation), 0-5V pulse. Detector signal output, 0-13V maximum. A/D Control signal out, 0-5V pulse. Trigger (syncs to drum…

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

…trig Out 1 delay
HSD 2 trig Out 2 delay
BWD BWD
HV 1 HV 1
Sync out delay
RF sync
Remote
motor
control
Oscilloscope
Legend Elite
Optical Bench Assembly
Chiller
Chiller
IN
OUT
IN
OUT
Air IN
Air OUT

Avia preinstall.book

Avia preinstall.book

…CONNECTOR TYPE MANUFACTURER PART NUMBER
Pulse Trigger In BNC (Jack) Amphenol 9350
External Enable BNC (Jack) Amphenol 9350
Pulse Sync Out BNC (Jack) Amphenol 9350
External Interface DB-25S ITT Cannon DBU25P (Note 1)
Interlock/Chiller DA-15S ITT Cannon DAU15P (Note 1)

COHR FidelityHP DS 0117 2.pdf

COHR FidelityHP DS 0117 2.pdf

…(VAC) 100 to 250, 50 to 60 Hz
Cooling Requirements
Air-cooled closed-loop chiller (included)
External Interfaces RS-232, USB, Sync Out
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature (°C) 15 to 35
Non-operating Temperature (°C) 0 to 40
Relative Humidity…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…Requirements (VAC) 100 to 250, 50 to 60 Hz
Cooling Requirements Air-cooled closed-loop chiller (included)
External Interfaces RS-232, USB, Sync Out
Operating Temperature (°C) 15 to 35
Non-operating Temperature (°C) 0 to 40
Relative Humidity (%)(non-condensing) <95

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…Requirements (VAC) 100 to 250, 50 to 60 Hz
Cooling Requirements Air-cooled closed-loop chiller (included)
External Interfaces RS-232, USB, Sync Out
Operating Temperature (°C) 15 to 35
Non-operating Temperature (°C) 0 to 40
Relative Humidity (%)(non-condensing) <95

ModeMaster PC User Manual

ModeMaster PC User Manual

…SIGNAL OUT from the ModeMaster PC
Control/Interface Console to Channel 1 on the oscilloscope, and by
connecting the Sync Out on the rear of the ModeMaster PC
Control/Interface Console to Channel 2 on the oscilloscope--refer
to Figure 1-4 (p. 1-6). The A/D Control Out signal shows…

LabMax-Pro SSIM User Manual

LabMax-Pro SSIM User Manual

…factory state.
Command: SYSTem:RESTore
Query: none
System Sync This command resets the system measurement sync timer. This
query gets the system measurement sync timer value. The system
measurement sync timer is a free-running timer that increments by
ten for every 10…

LaserCam-HR II User Manual

LaserCam-HR II User Manual

…occurs. The LaserCam-HR II can sample laser pulse repetition rates to a maximum of 200 Hz without averaging adjacent
pulses.
Trigger Out Coherent suggests that an external pulse generator be used if the
laser under test does not supply a "sync-out" signal. Connect the
pulse…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…diameter, profiles)
Module Update Rate
Analog Outputs Detector signal output, 0 to 13V maximum
A/D control signal out, 0 to 5V pulse
Trigger (syncs to drum rotation), 0 to 5V pulse
Power 100 to 240 VAC, 47 to 63 Hz, 40W maximum
Device
Specifications