Search Results

1 - 12 of 84 Products for 'Trigger Pulse' Page 1 of 7 |

Trigger Pulse

HELIOS

HELIOS

…125 kHz Pulse Width (FWHM) <0.79 ns <0.69 ns <0.95 ns <0.69 ns <0.85 ns Spatial Mode TEM 00 (M 2 < 1.25) Beam Diameter (Gaussian Fit, 1/e2) 3.5 mm 2.5 mm 2 mm Polarization Linear Jitter (between sequential pulses, gating mode) < ±2 ns Jitter (trigger to laser pulse, single pulse triggering) < ±2 ns…

Pulse Switch for Mira 900

Pulse Switch for Mira 900


* External trigger input (TTL)
* Digital and analog phase adjust of RF pulse (360°)
* Electronic delay
* Synchronization and RF pulse monitor outputs
* RF overload safety circuit Datasheet Pulse Switch for Mira 900 Drawing Pulse Switch for Mira 900 Cavity Dumper Accessory - With Pulse Switch, the…

HyperRapid NX/NXT - Industrial Picosecond Laser

HyperRapid NX/NXT - Industrial Picosecond Laser

…applications with state-of-the-art pulse control and synchronization features. Pulses can be triggered on-demand with low jitter (<25 ns) and trigger-to-pulse delay. The fast process shutter allows both on/off control and energy attenuation for each individual pulse. Burst mode can be selected to…

ModeMaster Modular Components

ModeMaster Modular Components

…out, 1 to 5V pulse Trigger (syncs to drum rotation), 0 to 5V pulse Detector signal outpur, 0 to 13V maximum A/D contorl signal out, 1 to 5V pulse Trigger (syncs to drum rotation), 0 to 5V pulse Detector signal outpur, 0 to 13V maximum A/D contorl signal out, 1 to 5V pulse Trigger (syncs to drum…

LAMBDA SX Excimer Laser Series

LAMBDA SX Excimer Laser Series

…superconductors by Pulsed Laser Deposition (PLD), Laser Lift-Off (LLO) to high power UV LIDAR. The E-Series is ideal for Excimer Laser Annealing (ELA). Contact Us About This Product Close PRICE HERE Model Name Wavelength (nm) Max. Pulse Frequency (Hz) Max. Pulse Energy (mJ) Max. Power…

IndyStar

IndyStar

--> IndyStar Fast Pulse, High Precision Processing IndyStar is a rugged high-duty cycle excimer laser designed for fast pulse frequency applications as high as 2000 Hz. Based on proven ALMETA tube technology, the Semi-S2 certified IndyStar operates over many billion pulses at ultra-short 193 nm and…

VYPER Series Lasers

VYPER Series Lasers

…(TwinVYPER) and LineBeam 1500 (TriVYPER) optics. Contact Us About This Product Close PRICE HERE Model Name Wavelength (nm) Max. Pulse Frequency (Hz) Max. Pulse Energy (mJ) Max. Power (W) VYPER 308 600 2000 1200 TwinVYPER 600 4000 2400 TriVYPER 600 6000 3600 Datasheet VYPER Applications Application…

LaserCam HR-InGaAs

LaserCam HR-InGaAs

…Modes of Operation Pulsed, CW default Pixel Size (µm) 30 x 30 Pulsed Mode Trigger Methods Trigger In (TTL) Saturation CW (at 1064 nm) 3.5 mW/cm2 (with LDFP), 50 µW/cm2 (without LDFP) Saturation CW (at 1523 nm) 350 µW/cm2 (with LDFP), 30 µW/cm2 (without LDFP) Saturation Pulse (at 1064 nm) 5 µJ/cm2…

ModeMaster PC M-Squared

ModeMaster PC M-Squared

…0-5V pulse. Trigger (syncs to drum rotation), 0-5V pulse. Detector signal output, 0-13V maximum. A/D Control signal out, 0-5V pulse. Trigger (syncs to drum rotation), 0-5V pulse. Detector signal output, 0-13V maximum. A/D Control signal out, 0-5V pulse. Trigger (syncs to drum rotation), 0-5V pulse.

LaserCam-HR II

LaserCam-HR II

…is fired after an external trigger signal that is shorter than the default camera trigger delay. Depending on the default trigger delay of the camera model and the repetition rate of the laser, the trigger delay feature assists in assuring that a valid laser pulse is captured on the camera during…

WaveMaster Wavelength Meter

WaveMaster Wavelength Meter

…required
* 380-1095 nm wavelength range
* RS-232 interface Contact Us About This Product PRICE HERE Close Pulse and CW Wavelength Measurement The WaveMaster measures the wavelength of both CW and pulsed lasers of any repetition rate. The wavelength can be displayed in GHz, wavenumbers, or nanometers…

LabMax-Pro SSIM

LabMax-Pro SSIM

…every 50 microseconds), enabling real-time analysis of modulated or pulsed systems.
* Snapshot mode provides burst sampling at a rate of 625 kHz (a sample every 1.6 microseconds), enabling users to view the temporal pulse traces of modulated lasers in the tens of microseconds or longer, commonly…