Search Results

Refine

Result Type

1 - 10 of 10 Products for 'Usx' Page 1 of 1 |
  • 1

Usx

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…beam pointing
and output energy stability
· Complete CEP amplifier system from a single manufacturer
· Available for Legend Elite USX and USP models
Legend Elite CE Phase Stability
GUI for Legend Elite CEP
Time (minutes)
CE Phase (rad)
-3
0
3

00 Legend Elite Preinstallation.book

00 Legend Elite Preinstallation.book

Laser Safety
1 - 11
Figure 1-3. Legend Elite HE+ USX Safety Labels (Covers Removed)
3
3
3
3
3
3
10
10

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…beam pointing
and output energy stability
· Complete CEP amplifier system from a single manufacturer
· Available for Legend Elite USX and USP models
Legend Elite CE Phase Stability
GUI for Legend Elite CEP
Time (minutes)
CE Phase (rad)
-3
0
3

LegendEliteDuoHEplus DS 0915revA 7b.pdf

LegendEliteDuoHEplus DS 0915revA 7b.pdf

…Specifications1 Legend Elite Duo HE+
Center Wavelength2 (nm) 795 to 805 780 to 820
Pulse Width Configuration
Pulse Width (fs)(FHWM) USX USP F P
<253,4 <355,6 <1105 500 to 10004,5
Repetition Rate7 (kHz) 1, 5 or 10
Contrast Ratio8
Pre-pulse >1000:1

COHR LegendEliteDuoHEplus DS 0119 1.pdf

COHR LegendEliteDuoHEplus DS 0119 1.pdf

SPECIFICATIONS1 Legend Elite Duo HE+
Center Wavelength2 (nm) 795 to 805 780 to 820
Pulse Width Configuration
Pulse Width (fs) (FHWM)
USX
<253,4
USP
<355,6
F
<1105
P
500 to 10004,5
Repetition Rate7 (kHz) 1, 5, or 10
Contrast…

COHR TOPAS-Prime DS 0217 2.pdf

COHR TOPAS-Prime DS 0217 2.pdf

…Libra systems at 1 kHz (contact factory for other pump systems). Specifications for harmonic wavelengths
pumped by Legend Elite USX and Legend Elite Duo USX models are 25% lower.
2 Energy scales linearly with pump in range 0.3 mJ to 4 mJ for <130 fs pump and 0.3 mJ to 3.5 mJ for <50…

LegendEliteHEplus DS 0715revA 6.pdf

LegendEliteHEplus DS 0715revA 6.pdf

…System Specifications1 Legend Elite HE+
Center Wavelength2 (nm) 795 to 805 780 to 820
Pulse Width Configuration
Pulse Width (fs)(FHWM) USX USP F P
<253,4 <355 <1105 500 to 10005,6
Repetition Rate7 (kHz) 1, 5 or 10
Contrast Ratio8
Pre-pulse >1000:1

Legend-Elite-HE-Data-Sheet.pdf

Legend-Elite-HE-Data-Sheet.pdf

…System Specifications1 Legend Elite HE+
Center Wavelength2 (nm) 795 to 805 780 to 820
Pulse Width Configuration
Pulse Width (fs)(FHWM) USX USP F P
<253,4 <355 <1105 500 to 10005,6
Repetition Rate7 (kHz) 1, 5 or 10
Contrast Ratio8
Pre-pulse >1000:1

COHR LegendEliteHEplus DS 0119 1.pdf

COHR LegendEliteHEplus DS 0119 1.pdf

…SPECIFICATIONS1 Legend Elite HE+
Center Wavelength2 (nm) 795 to 805 780 to 820
Pulse Width Configuration
Pulse Width (fs) (FHWM)
USX
<253,4
USP
<355,6
F
<1105
P
500 to 10004,5
Repetition Rate7 (kHz) 1, 5, or 10
Contrast Ratio8…

Legend-Cryo-PA DS

Legend-Cryo-PA DS

Center Wavelength (nm)(nominal) 800
Repetition-Rate Options1 (kHz) 1, 5, or 10
Pulse Duration2 (fs)(FWHM) <30 (USX model), <40 (USP model)
Energy-per-Pulse3 (mJ) Options to >20
Contrast Ratio4 (ns) >1000:1 pre-pulse; >100:1 post-pulse
Contrast Ratio (ASE)…