Search Results

Refine
1 - 11 of 11 Products for 'Variable Attenuator' Page 1 of 1 |
  • 1

Variable Attenuator

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

Variable Attenuator Modules (C-VARM
and UV C-VARM) contain two wedge attenuators that are
continuously variable and a step attenuator that allows
attenuation from 107:1 down to 3000:1.The C-VARM and
UV C-VARM can be finely adjusted to achieve both precise
attenuation levels…

UV Optical Components

UV Optical Components

--> UV Optical Components Making the most of a UV laser beam. Contact Us About This Product Close PRICE HERE Attenuators Attenuator Module, Manual Variable attenuation substrate 60 x 35 x 2 mm 3 with inverse characteristic for high thermal stability. Compensator plate 60 x 35 x 2 mm 3 to compensate…

C24 Program

C24 Program

…FieldMaxII-TO + PM30 S-1551 FieldMaxII-TO + PS19 Accessories Beam Diagnostic Accessories BeamCube Fixed Attenuator - BCUBE Continuous Variable Attenuator - C-VARM UV Continuous Variable Attenuator - UV-C-VARM Power Sensor Accessories 1000:1 Attentuator FC/PC Type Connector Thermal SmartSensor…

drw

drw

IN FIXED ATTENUATION VARIABLE ATTENUATION MAX MIN MAX MIN OUT 79.4 mm (3.13 in. ) 63.5 mm (2.5 in. ) 58.7 mm (2.3 in. ) 57.1 mm (2.25 in.) 44.5 mm (1.75 in.) C-Mount Thread C-VARM and UV C-VARM

COHR ExcimerCatalog2019.pdf

COHR ExcimerCatalog2019.pdf

coherent.com 43
Excimer Lasers and UV Optical Systems Components: Attenuator Modules
Components
Attenuator Modules
Attenuator Module, Manual
- Variable attenuation substrate 60 x 35 x 2 mm3 with inverse characteristic for high thermal stability
- Compensator plate 60 x…

COHR HRNX SmartCleave DS 0718 3.pdf

COHR HRNX SmartCleave DS 0718 3.pdf

…non-condensing, Dew-point <22°C
1 At lowest amplifier pulse repetition rate, unless stated otherwise.
2 Maximum output power (variable attenuator and process shutter at maximum transmission).
3 After warm-up time.
4 Steady-state (no pulse gating or change of pulse repetition…

COHR HyperRapidNXT DS 0619 3.pdf

COHR HyperRapidNXT DS 0619 3.pdf

…Steady-state (no pulse gating or change of pulse repetition rate).
4 Single-pulse operation (burst number = 1).
5 Maximum power with variable attenuator and process shutter at maximum transmission.
6 Over 8 hours, ±1°C ambient temperature.
7 With 5 pulses in the burst, at the…

COHR HyperRapidNX DS 0618 1.pdf

COHR HyperRapidNX DS 0618 1.pdf

…non-condensing, Dew-point <22°C
1 At lowest amplifier pulse repetition rate, unless stated otherwise.
2 Maximum output power (variable attenuator and process shutter at maximum transmission).
3 After warm-up time, chiller temperature = 23 ±0.1°C.
4 Steady-state (no pulse…

Microsoft Word - Understand Different Laser Beam  Rev 1 Final.doc

Microsoft Word - Understand Different Laser Beam Rev 1 Final.doc

…low µW/cm² or mJ/cm². Some
form of attenuation will almost always be needed with camerabased systems. Most manufacturers will offer attenuators as part of
their camera-based product line.
A special feature of camera-based analyzers is variable camera
exposure time, which allows…

Article

Article

…duration (Fig. 2). The pulses were compressed using a double-pass, dual-grating compressor with variable
length to access pulse durations between 400 fs and 18 ps. The compressed pulses were attenuated with a
rotatable half-wave plate and a polarizer. A quarter-wave plate transformed the…

Biosafety Level 3 setup for multiphoton microscopy in vivo

Biosafety Level 3 setup for multiphoton microscopy in vivo

…is used as excitation
light source for conventional MPM. The beam control (BeamOptimizer, Lavision BioTec) uses a polarizer/analyzer as attenuation and an electro optical Modulator for fast beam switching for line blanking and phototreatment applications. A telescope adapts the beam diameter…