Search Results

1 - 12 of 29 Products for 'Verdi Specifications' Page 1 of 3 |

Verdi Specifications

COHR Verdi G-Series DS 0118 7.pdf

COHR Verdi G-Series DS 0118 7.pdf


(16.1 in.)
236 mm
(9.3 in.)
150 mm
(5.9 in.)
Top View
Side View Rear View
Verdi G-Series Datasheet
MECHANICAL SPECIFICATIONS
Verdi G2/G5/G7/G8/G10
Benchtop Power Supply
Verdi G12/G15/G18/G20
Benchtop Power Supply
Front View

VERDI newlayout

VERDI newlayout

…the superb
resonator mechanical stability that you get with
Verdi. And thanks to its single-frequency design and
exclusive, advanced noise-control circuitry, Verdi has
the lowest optical noise specification of any laser in
its class--without the mode-beating noise that's…

Vitara

Vitara

…bandwidth and center wavelength (Vitara-T and Vitara-T-HP)
* PowerTrack active optimization
* 30 pulsewidth capability (Vitara-T)
* Integrated Verdi G pump laser
* Compact footprint
* HASS verified for quality and reliability Benefits Application Vitara Model Amplifier Seeding Vitara-S provides…

CEP for Legend Elite Amplifiers

CEP for Legend Elite Amplifiers

…system of this type. Specifically, the Legend Elite Duo CEP delivers up to 10 Watts of power, as well as higher repetition rates (up to 10 kHz), yet it does not require the complexity of cryogenic cooling of the gain medium, unlike systems offered by competitors. With the Verdi pumped Vitara CEP and…

Solar Cell Manufacturing

Solar Cell Manufacturing

…production environments. Laser ‘doping’ can also be performed simultaneously with groove scribing or Dielectric Ablation. Related Products Verdi G Series Verdi V Series Paladin Advanced 355 Paladin Advanced 532 c-Si Dielectric Ablation Lasers and laser process tools enable highest precision c-Si…

Microelectronics

Microelectronics

…a result, they have been implemented in a wide range of micromachining applications. The following text outlines some important applications and specific laser requirements .This photo shows excimer-micromachined script on a 120 micrometer diameter human hair. This is an example of high-resolution…

Life Sciences and Medical Applications

Life Sciences and Medical Applications

…or IR light and a small fraction of the incident radiation is scattered and shifted at frequencies that correspond to vibrational transitions specific of the sample. The Raman signal is much weaker than the incident and scattered light, so it may be difficult to detect it, unless appropriate…

Verdi preinstall.book

Verdi preinstall.book

Verdi V-18 Laser Preinstallation Manual
8
Figure 1-6. Interconnect Diagram
Table 1-1. Utility Requirements
PARAMETER REQUIREMENT
Power Requirements 100 to 240 VAC[1][2]50 to 60 Hz
Maximum Current 14 Amps @ 100 VAC
7 Amps @ 220 VAC
Power consumption 2.0 kW…

Mira-Optima-900-D-Data-Sheet.pdf

Mira-Optima-900-D-Data-Sheet.pdf

…Noise6 <0.1% (Verdi) <2% (Sabre/Innova) Stability7 <3% (Verdi) <5% (Sabre/Innova) Beam Diameter8 0.8 mm Beam Divergence9 1.7 mrad Spatial Mode10 TEM00 Polarization Horizontal Physical Dimensions 111.1 x 38.1 x 19.7 cm (43.75 x 15 x 7.75 in.) System Specifications1 1 Specifications apply only with…

Mira-Optima-900-F-Data-Sheet.pdf

Mira-Optima-900-F-Data-Sheet.pdf

…Noise6 <0.1% (Verdi) <2% (Sabre/Innova) Stability7 <3% (Verdi) <5% (Sabre/Innova) Beam Diameter8 0.8 mm Beam Divergence9 1.7 mrad Spatial Mode10 TEM00 Polarization Horizontal Physical Dimensions 111.1 x 38.1 x 19.7 cm (43.75 x 15 x 7.75 in.) System Specifications1 1 Specifications apply only with…

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…1600 to 2400
Noise2 (%) ±2.0
Stability3 (%) ±2.0
M2 <2.0
1 Specifications based on output of one OPA, 10W Verdi pumping a RegA 9000/9050, and Mira/Verdi seeding.
Same specifications apply for two simultaneously pumped OPAs at 100 kHz.
2 Peak-to-peak noise measured…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…mounting surface.
3 Mira-900 pumped by Verdi G5 or Verdi G10.
4 Real pulse width assuming sech2 deconvolution factor of autocorrelation.
Typical Cavity Dumper Performance
(Mira-900-D at 800 nm, 4.5W Verdi pump power)
Specifications
Pulse Repetition Rate (kHz)
Pulse…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions