Search Results

1 - 12 of 107 Products for 'Vibration' Page 1 of 9 |
Related Categories: Chameleon Laser

Vibration

Chameleon Reliability Antarctia Final WP.pdf

Chameleon Reliability Antarctia Final WP.pdf


statistical HASS at the production stage. HASS
includes simultaneous temperature and 3D vibration
cycling with changes in temperature between -40 oC
and +60 oC and vibration at 10g level over a wide range
of frequencies, as exemplified in Figure.5. This test is

OBIS LX/LS Heat Sink

OBIS LX/LS Heat Sink

…LX/LS Heat Sink enables operation throughout the entire specified temperature range from 10°C to 40°C. It incorporates a cooling fan with added vibration isolation in a robust design and small footprint. The fan connector plugs directly into any the laser head of any OBIS LX/LS laser head, allowing…

Compass 115M

Compass 115M

…are aligned to optimum and then permanently fixed by soldering making the lasers optimally aligned over their whole lifetime, insensitive to vibration and thermal cycles. The lasers are manufactured in controlled clean rooms and hermetically sealed before being end-tested extensively.
* Patented…

Fidelity-2

Fidelity-2

…an industrial-grade HALT (Highly Accelerated Life Testing) protocol in which the system being produced is subjected to both temperature and vibration cycles in order to expose the weakest links and eliminate them. HASS (Highly Accelerated Stress Screening) is used during manufacturing to weed…

Fidelity HP

Fidelity HP

…an industrial-grade HALT (Highly Accelerated Life Testing) protocol in which the system being produced is subjected to both temperature and vibration cycles in order to expose the weakest links and eliminate them. HASS (Highly Accelerated Stress Screening) is used during manufacturing to weed…

RAPID FX

RAPID FX

…<1500W Temperature (non-condensing) - Laser Head +15 to 30°C (59 to 86°F) Temperature (non-condensing) - Chiller +15 to 30°C (59 to 86°F) Vibration <0.15 g Temperature -10 to +50°C (-14 to 122°F) Temperature Gradient 15°C (59°F) per hour Relative Humidity 5% to 90% Shock 5 g in 30 ms High…

Compass Lasers

Compass Lasers

…are aligned to optimum and then permanently fixed by soldering making the lasers optimally aligned over their whole lifetime, insensitive to vibration and thermal cycles. The lasers are manufactured in controlled clean rooms and hermetically sealed before being end-tested extensively.
* Patented…

AVIA NX nanosecond laser

AVIA NX nanosecond laser

…with its own dedicated environmental test chamber. HALT during the design phase:
* Temperature and vibration tests on components, assemblies and systems
* 12 hour tests constant random vibration and broad temperature swings
* Component re-design based on results HASS for Beta and production units:…

Ultrafast Laser Oscillators and Amplifiers

Ultrafast Laser Oscillators and Amplifiers

…an industrial-grade HALT (Highly Accelerated Life Testing) protocol in which the system under development is subjected to both temperature and vibration cycles in order to expose the weakest links and facilitate their elimination. A less severe stress protocol, HASS (Highly Accelerated Stress…

Sapphire Lasers

Sapphire Lasers

…optimum and then soldered. Therewith the optimal alignment is frozen over the lifetime of the product, the laser becomes highly insensitive to vibration and thermal cycles. All Sapphire lasers are manufactured in controlled cleanrooms and hermetically sealed, before being run through rigorous…

Ultrafast Amplifiers

Ultrafast Amplifiers

…an industrial-grade HALT (Highly Accelerated Life Testing) protocol in which the system under development is subjected to both temperature and vibration cycles in order to expose the weakest links and facilitate their elimination. A less severe stress protocol, HASS (Highly Accelerated Stress…

Ultrafast Oscillators

Ultrafast Oscillators

…an industrial-grade HALT (Highly Accelerated Life Testing) protocol in which the system being produced is subjected to both temperature and vibration cycles in order to expose the weakest links and eliminate them. HASS (Highly Accelerated Stress Screening) is used during manufacturing to weed…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions