Search Results

1 - 12 of 85 Products for 'air cooled lasers' Page 1 of 8 |

air cooled lasers

Diode Lasers Enable Diverse Therapeutic Applications

Diode Lasers Enable Diverse Therapeutic Applications

…for scientific, commercial and industrial customers. For more information about Coherent, visit the company's website. www.coherent.com Company Fig. 1 Integration chain from a conduction cooled laser diode bar, via a fiber coupled laser diode module, up to a turnkey, air cooled diode laser system.

Advances in Diode Lasers and OPSLs

Advances in Diode Lasers and OPSLs


gas lasers. In addition to optical noise, air-cooled gas
lasers also suffer from disturbing fan vibrations and air
flow/turbulences, required by their high cooling
demand. These consequences/after-effects of the high
(air-) cooling demand simply do not exist with laser

00 Laser Cooling.book

00 Laser Cooling.book

…through the use of cooling water.
Advantages of
Water Cooling
Ion lasers are typically cooled by means of air flow or water flow.
Ion laser efficiency of input-to-output power is typically
0.02 - 0.04%. The practical limit to cool ion lasers by direct air flow
is 500 mW…

CO Lasers from Lab to Fab

CO Lasers from Lab to Fab

…process using the CO
2
laser. The CO laser can cut thin glass
(in the 50 µm to 300 µm thickness
range) directly, without the need for an
air or water cooling jet often required
in tandem with the CO
2
laser. The CO
laser not only eliminates the need for a…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

…Series lasers can condense moisture
from the air when the temperature of the cooling fluid is at or below
the dew point of the air.
NOTICE!
The system must not operate in a condensing environment since
this condition will lead to catastrophic failure in both the laser

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

…Series lasers can condense moisture
from the air when the temperature of the cooling fluid is at or below
the dew point of the air.
NOTICE!
The system must not operate in a condensing environment since
this condition will lead to catastrophic failure in both the laser

High Power Fiber Lasers for Welding  COHR Rofin whitepaper.pdf

High Power Fiber Lasers for Welding COHR Rofin whitepaper.pdf

…clamping mechanism having integrated
cooling. This method evenly clamps the part at all welding points, while the cooling
prevents the joints from warping.
The testing also allowed Coherent | Rofin personnel to recommend a 2 kW fiber laser
(Coherent | Rofin FL 020) with a 300 µm…

Picosecond laser

Picosecond laser


l
Laser fibers cannot be disconnected (neither from the laser
head nor from the power supply).
l
Connections between devices in the rack might be too short
if the devices are taken out of the rack (or changed in its
order). Some cables (e.g. laser fibers) cannot…

Laser Focus World - August 2016

Laser Focus World - August 2016

August 2016 www.laserfocusworld.com Laser Focus World
30
MarketInsights
thus came to dominate flow cytometry
in the 1980s. Over time, however, the
ongoing evolution of highly reliable and
compact air-cooled argon lasers enabled
construction of smaller (though still…

Laser Focus World - January 2018

Laser Focus World - January 2018

…developed parallel cooling that is modular in configuration to allow for different-sized stacks
(see Fig. 3).
For high LD powers and water-flow
rates, a closed-loop water circulation system conserves water and thus costs. Such
systems are often cooled by laser chillers,

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

Preinstallation Manual Paladin Advanced Mode Locked UV Laser System

…heat generated
inside the laser head is in the range of 150 W and must be removed.
Due to the high pointing stability requirements of some applications,
an air cooling solution is not possible. In an air-cooled system, the
temperature of the laser housing changes with ambient…

Verdi preinstall.book

Verdi preinstall.book

…the laser. The
main power disconnect switch shall be clearly marked as the disconnecting device for the laser, and shall be
within easy reach of the operator.
LASER HEAD AIR COOLED
POWER SUPPLY
UMBILICAL
FACILITY
POWER
WATER LINES (if using Water Cooling)

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions