1 - 10 of 348 Search Results for alignment
|
|
|
1.
Low Power
|
|
... crystal temperature, and should be between 2.5 and 3.0 Volts. Verify the PowerTrack PZTs are between 2 and 3 Volts. The PowerTrack PZTs optimize the alignment of the Verdi beam into the ultrafast head. They have a range of 0-5 Volts and should ideally be between 2 and 3 Volts. Operate the laser at normal ...
Related Searches: verdi laser
|
|
|
|
|
3.
COMPexPro® Accessories
|
|
|
... Precision Optics Related Accessories For detailed specifications, see part number. Name Description Beam Aligner Diode laser (670 nm) and alignment mechanics. Requires dielectrically coated rear mirror optic. Unstable Resonator Optics 100 (193 nm) For COMPexPro 100 series Unstable Resonator Optics ...
|
|
|
|
|
5.
Ultra-Low Noise Diode Laser Modules
|
|
|
... necessary +5V and +12V to drive the laser. Use the LabLaser mount [part no. 0221-449-00] for convenient heat sinking and mounting with adjustable alignment. ULN circular diode laser modules create a 1 mm circular output beam using MicroBlaze patented technology. This is a technique that accurately positions ...
|
|
|
|
6.
Coherent_2007_accessible
(PAGE 23 OF 162)
|
|
|
Compensation Discussion and Analysis Our Executive Compensation Philosophy Our executive compensation programs are designed to provide strong alignment between executive pay and performance and to focus executives on making policies and decisions that enhance Coherent's shareholder value over time ...
|
|
|
|
7.
Sapphire488&460_DSrevF_8a
(PAGE 2 OF 2)
|
|
... 20 kHz, peak-to-peak <1% Long-Term Power Stability (2 hours, ±3°C) <2% Warm-Up Time <5 min. Polarization Ratio >100:1, vertical Static Alignment Tolerances3 Beam Position ±0.25 mm Beam Angle ±2.5 mrad Beam Waist Position at Exit Window ±200 mm4 Operating Voltage5 +10.8 to 15 VDC Power Consumption ...
Related Searches: ps10q
|
|
|
|
9.
Intra_ocular_lenses_2
(PAGE 2 OF 4)
|
|
|
... toric lens is manufactured with a laser engraved reference marking. The surgeon then can easily and quickly identify the axis of symmetry for proper alignment when placing the lens in the patient's eye. While these markings are easily identified by the ophthalmologist, they do not affect the sight capabilities ...
|
|
|
|
|
10.
Not Modelocking
|
|
... Highest level of post-sale customer care Long-term customer relationships For Vitesse lasers – Verify the baseplate is 25 ± 1ºCelsius. Optimum alignment of the Verdi pump beam into the ultrafast head can only be achieved if the baseplate temperature is 25 ± 1ºCelsius. Adjust the chiller temperature ...
Related Searches: baseplate verdi | troubleshooting
|
|