1pdf document  COHR LifeSciencesGuide2012revG Best match in this PDF  |  All matches in this PDF
Stability <6 µrad/°C Beam Spatial Mode (Far Field) TEMoo ESD Protection4 Level 4 Dimensions (Diameter x Length) 44.5 x 218 mm (1.75 x 8.6 in.) Optional Control Box (L x W x H) 138 x 62 x 26 mm (5.4 x 2.4 x 1 in.) Ambient Temperature Range for Operation5 10°C to 40°C (50°F to 104°F) Storage Temperature
Related Searches: dpss 532 200 mw | 488 sapphire | chameleon ultra 2 | line beam

2pdf document  Laser Cooling Water Guidelines Best match in this PDF  |  All matches in this PDF
…water temperatures are also subject to seasonal variations. Insure Table 2. Innova Inlet Temperature RANGE 10° - 35°C (50° - 95°F), always above ambient dew point. See "Selecting the Correct Cooling Water Temperature" on page 16. STABILITY ±1°C (1.8°F) during operation Laser system stability (power…
Related Searches: water chiller | water chiller manual | water cooling | innova 300 manual

3pdf document  COHR DLM2011 Catalog FINAL Best match in this PDF  |  All matches in this PDF
Stability <6 rad/°C Beam Spatial Mode (Far Field) TEMoo ESD Protection4 Level 4 Dimensions (Diameter x Length) 44.5 x 218 mm (1.75 x 8.6 in.) Optional Control Box (L x W x H) 138 x 62 x 26 mm (5.4 x 2.4 x 1 in.) Ambient Temperature Range for Operation 10°C to 40°C (50°F to 104°F)5 Storage Temperature
Related Searches: 635-25 | powell lens | lasiris dlsc | focusing lens

4pdf document  Innova300C fredmotofred preinstallation Best match in this PDF  |  All matches in this PDF
…water temperature that should be observed for the current room temperature and humidity conditions. In many climates, the cooling water temperature should be changed due to seasonal variations in the ambient conditions. For example in times of high relative humidity and high room temperatures, the cooling…
Related Searches: innova 90 | innova 300c | innova manual | bbo crystal

5pdf document  Innova90C preinstallation Best match in this PDF  |  All matches in this PDF
…water temperature that should be observed for the current room temperature and humidity conditions. In many climates, the cooling water temperature should be changed due to seasonal variations in the ambient conditions. For example in times of high relative humidity and high room temperatures, the cooling…
Related Searches: innova 90 manual | innova 90c manual | cooling | innova 70 user manual

6pdf document  Innova 300C preinstallation Best match in this PDF  |  All matches in this PDF
…water temperature that should be observed for the current room temperature and humidity conditions. In many climates, the cooling water temperature should be changed due to seasonal variations in the ambient conditions. For example in times of high relative humidity and high room temperatures, the cooling…
Related Searches: lm20 | cooling | krypton laser | lm-20

7pdf document  Innova 322C Preinstallation Best match in this PDF  |  All matches in this PDF
…minimum water temperature that must be observed for the current room temperature and humidity conditions. In many climates, the cooling water temperature must be changed due to seasonal variations in the ambient conditions. For example in times of high relative humidity and high room temperatures, the cooling…
Related Searches: integrated cooling exchanger | i322c | innova 300 manual | innova 90

8pdf document  Paladin Preinstallation RevAA Best match in this PDF  |  All matches in this PDF
…are mounted on a kinematically mounted resonator for strength and stability. The temperature of the gain medium is controlled by TECs (thermo-electric coolers) that are capable of heating or cooling the optical element. The temperatures of the SHG and THG crystals are set to approximately 150°C and 60°C…
Related Searches: water chiller manual | laser diode modules | laser diode | optishield

9pdf document  RadiusHeNeCC 100103 June09Update Best match in this PDF  |  All matches in this PDF
…Power Stability Over Time At a constant room temperature, the RADIUS 635 delivers rock-solid output power. Superior Beam Pointing RADIUS' user-transparent active temperature stabilization minimizes ambient effects. Alignmentsensitive applications are improved--immediately. Reliable Output Stability 0 50…
Related Searches: he-ne laser | 635 | pointing stability

10pdf document  Sabre Preinstallation Best match in this PDF  |  All matches in this PDF
…water temperature that should be observed for the current room temperature and humidity conditions. In many climates, the cooling water temperature should be changed due to seasonal variations in the ambient conditions. For example in times of high relative humidity and high room temperatures, the cooling…