Search for Lasers, Laser Systems, Laser Measurment, Laser Service Coherent Inc., Worldwide websites Coherent Inc., calendar of events Coherent Inc., office locator Coherent Inc., Service Centers
     > Search
Search Coherent
Coherent Inc.
Superior Reliability & Performance
  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
Please enter a search phrase.

1 - 10 of 102 Search Results for amp
Search Suggestions: pyroelectric detector | p2-49 | radiometer | spectrometer | quadrant detector | ops | p5

1pdf document  BioinstrumentationOverview2008View  (PAGE 6 OF 36)
Sapphire 488 & 460 LP Low Power, CW Blue Lasers Features · Proven reliability · Lowest cost of ownership · Superior beam quality · Outstanding power stability · Analog and digital interface · Up to 75 mW @ 488 nm Mechanical Specifications 4 DC Supply for fan (AMP-MODU-2pin-male) Interfacing Part ...

2pdf document  Innova_322C_Preinstallation  (PAGE 24 OF 30)
... the lab indicating that the system is ionized and possibly lasing. This switch is isolated from all other laser circuits. It is rated for 30 VAC, 12 Amps (maximum). It is not internally protected by fuses or other overcurrent protection devices. Refer to Figure 3 for TB1 pin-outs. Heat Exchanger Control ...

3pdf document  BioinstrumentationOverview2008View  (PAGE 8 OF 36)
Sapphire 488 HP High Power, CW Blue Lasers Features · Proven reliability · Air-cooled package · Outstanding power stability · Analog & digital interface · Up to 500 mW @ 488 nm Mechanical Specifications 6 Laser Head Controller 81,3 0,160 4,1 3,200 127 5,000 241.3 mm (9.5 in.) 127 mm (5.0 in.) Analog ...

4pdf document  FAP_Integrated_Package_DS Best match in this PDF  |  All matches in this PDF
... number DBPE 1031 A012-130 and supplied with every unit. TEC Connector Pin-out Pin 1 and Pin 2: TEC + Pin 3 and Pin 4: TEC - TEC Current maximum 7 Amps TEC Voltage maximum 60V Connector is W.W. Fischer, part number S103 A053-60/6.75 and supplied with every unit. Recommended Heat Sink Capacity 500W Thermal ...
Related Searches: sma-905 connector | fap-i | sma-905 | price list

5pdf document  Diamond_E-400_Preinstallation_RevAA  (PAGE 14 OF 31)
Diamond E-400 Preinstallation Manual 8 Table 2. Utility Requirements PARAMETER REQUIREMENT ELECTRICAL Input DC voltage(1) + 48 VDC ± 0.5%, 170 Amps (240 Amps peak for 1 msec) COOLANT(2) Minimum flow rate 2.5 gpm (9.5 liters/minute) Inlet pressure(3) 50 to 75 psi (345 to 520 kPa) Pressure differential ...

6pdf document  Innova90C_preinstallation  (PAGE 24 OF 32)
... the lab indicating that the system is ionized and possibly lasing. This switch is isolated from all other laser circuits. It is rated for 30 VAC, 12 Amps (maximum). It is not internally protected by fuses or other overcurrent protection devices. Refer to Figure 3 for TB1 pin-outs. Heat Exchanger Control ...
Related Searches: heat exchanger

7pdf document  Innova300Datasheet Best match in this PDF  |  All matches in this PDF
... .2% 0.5% 0.5% 0.2% 0.3% Utility Requirements Input Power 3-phase with ground, nominal 208 volts Voltage Range ±10% +10%/-7.5% Maximum Current Draw in amps/phase at 208 vac 45-557 55 55 50 60 45 50 Cooling Water Flow Rate in L/min8 8.5 9.6 9.6 8.5 9.6 8.5 9.6 Pressure in kPa9 170-415 240-415 240-415 170 ...
Related Searches: innova 300 | argon ion laser | innova 305 | argon

8pdf document  Epm2000RG Best match in this PDF  |  All matches in this PDF
... reproduced or transmitted in whole or in part in any form or by any means without permission of the publisher. Document Number: QD-19.17 Features & Description . 1 Welcome . 1 Overview . 1 SafetyInformation . 2 ManualInformation. 3 Features . 3 Interface . 3 UnitsandRanges . 3 Compatible Probes ...
Related Searches: epm2000 | molectron power meter | bnc adapter | j25

9pdf document  Innova300CmotoFredDatasheet Best match in this PDF  |  All matches in this PDF
Input Power 3-phase with ground Voltage 208 ±10% vac, 50 or 60 Hz Maximum Current Draw 60 amp/phase @ 208 vac Cooling-Water Flow Rate 8.5 liter/min (2.2 gallon/min) Cooling-Water Pressure 1.41 to 4.23 kg/cm3 , 20 to 60 psi Cooling-Water Incoming Temperature 10 to 35°C (50 to 95°F) Purge 0.5-1.0 SCFH ...
Related Searches: 257 nm | motofred | 300c | power supply

10pdf document  Verdi_V2-V5-V6_Preinstallation  (PAGE 14 OF 18)
... . Figure 1-6. Interconnect Diagram Table 1-1. Utility Requirements PARAMETER REQUIREMENT Power Requirements 100 to 240 VAC[1][2] Maximum Current 6.5 Amps @ 100 VAC 7 Amps @ 220 VAC Cooling: Laser head: Power supply: Riser/heat sink[3] Air-cooled with ambient air Note: All specifications and requirements ...


Search Suggestions: pyroelectric detector | p2-49 | radiometer | spectrometer | quadrant detector | ops | p5
Page 1 2 3 4 5 6 7 8 9 10 11>> of 11 | Next