Search Results

37 - 48 of 107 Products for 'aperture' Page 4 of 9 |

aperture

PowerMaxPro 150FBB 150FHD drawing

PowerMaxPro 150FBB 150FHD drawing

…mm (3.75 in.) 109 mm (4.3 in.) 51 mm (2.0 in.) 51 mm (2.0 in.) 76 mm (3.0 in.) Note: Detector surface is 9.8 mm (0.38 in.) below front face of aperture plate 44 mm (1.75 in.) 30 mm (1.18 in.) 1/4-20 UNC Mounting Hole 10 mm (0.39 in.) 2X 6-32 UNC Mounting Hole 6 mm (0.25 in.) 2X M4X0.7 - 6H Mounting…

LaserCheck Operating Instructions

LaserCheck Operating Instructions

…...........................................................0.01 µW Min. detectable power .............. 3 to 10 µW (wavelength dependent) Aperture size ............................................................................ 8 mm Built-in range step attenuator .................................…

DFG9800 DSrevA 3.qxd

DFG9800 DSrevA 3.qxd

…95056 M/N S/N MFD THIS PRODUCT COMPLIES WITH DHHS/CDRH RADIATION PERFORMANCE STANDARDS 21 CFR SUBCHAPTER J AVOID EXPOSURE IS EMITTED FROM THIS APERTURE VISIBLE AND INVISIBLE LASER RADIATION Verdi V10 RegA 9000 Vitesse OPA 9800 DFG 9800/9850 12.07 cm (4.75 in.) 121.92 cm (4 ft.) 15.47 cm (6.09 in.)…

CUBE 640FP DS

CUBE 640FP DS

…(-4°F to +176°F) Humidity Resistance Minimum 40 Cycles (MIL-STD-810E) Method 507 Procedure 1 Dimension (mm) 25.4 (24.4 mm without ring) Useable Aperture (mm) 23 ±0.4 Thickness (mm) 4 ±0.25 (3 mm without ring) Available Band Pass (at FWHM) 20 nm (0 to 15° angle of incidence) 40 nm (0 to 25° angle of…

Properties-of-Structured-Light-Application-Note.pdf

Properties-of-Structured-Light-Application-Note.pdf

…as a plane wave with a Gaussian intensity profile. This profile is clipped to a finite diameter either by the laser cavity or other mechanical aperture. The most common way to define the properties of a Gaussian beam is by establishing the diameter of the beam and then applying this definition of…

OBIS GalaxySystem Datasheet COHR 2018.pdf

OBIS GalaxySystem Datasheet COHR 2018.pdf


<10W
MECHANICAL SPECIFICATIONS
FC/APC
Distal End - Output
FC Connector Key
Polarization
±2° Max.
Laser Aperture
Polish Direction
Not Applicable to
FC/UFC Connector
View of Fiber from
Connector End
3 mm PVC
Coated Monocoil…

Photonics Spectra - October 2016

Photonics Spectra - October 2016

…of these parts.
Most current optics always have a clear
aperture specified that is smaller than the
outer-most dimensions of the surface."
One way to reduce component size is to
bring the clear aperture right to the edge
of the part, which means that any coatings need…

PowerMax-Pro-Data-Sheet FORMFIRST.pdf

PowerMax-Pro-Data-Sheet FORMFIRST.pdf


200 mW to 150W ±3
50 mW to 200 mW <6
Spectral Compensation Accuracy (%) ±2 ±3 ±2 ±3
Spatial Uniformity (%)(center 75% of aperture; 2.5 mm beam) ±5
Calibration Wavelength (nm) 810
Cooling Method Water/Air (intermittent) Water/Air (intermittent) Fan Fan
Maximum…

COHR DiamondCx-10LQS DS 0118 3.pdf

COHR DiamondCx-10LQS DS 0118 3.pdf

…(1.42 in.)
36.0 mm
(1.42 in.)
18.0 mm
(0.71 in.)
99.3 mm
(3.91 in.)
Ø 15.9
(0.625 in.)
Output
Aperture
542.0 mm (21.34 in.)
Ø6 mm (0.236 in.)
Purge Connection
Ground
+48VDC
182.3 mm (7.18 in.)
781.4 mm (30.76 in.)…

COHR CUBE DS 0818 4.pdf

COHR CUBE DS 0818 4.pdf

…mm
(0.25 in.)
90 mm
(3.54 in.)
Ø4.2 mm
(0.17 in.)
4 PLACES
Ø3 mm
(0.118 in.)
Dowel Hole
Laser Aperture USB
DE-15
Digital Modulation
SMB
3 x 7 mm
(0.118 x 0.28 in.)
Dowel Slot
5 mm
(0.20 in.)
19 mm

COHR FAP600Series DS 0917 1.pdf

COHR FAP600Series DS 0917 1.pdf

…(TC) = 25°C.
2 Custom center wavelengths and custom spectral widths are available, some from stock. Consult your Coherent representative.
3 The numerical aperture of the output beam is defined as the sine of the half-angle of the divergence cone that encircles 90% of the energy.

COHR FAP800Series DS 0917 1.pdf

COHR FAP800Series DS 0917 1.pdf

…(TC) = 25°C.
2 Custom center wavelengths and custom spectral widths are available, some from stock. Consult your Coherent representative.
3 The numerical aperture of the output beam is defined as the sine of the half-angle of the divergence cone that encircles 90% of the energy.

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions