Search Results

Refine
13 - 24 of 29 Products for 'autocorrelator' Page 2 of 3 |

autocorrelator

COHR Astrella DS 0117 3.pdf

COHR Astrella DS 0117 3.pdf

…shipment.
3 A Gaussian pulse shape de-convolution factor (0.7) is used to determine the pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator).
4 Contrast ratio is defined as the ratio between the peak intensity of the output pulse to the peak…

COHR RegA DS 0217 1.pdf

COHR RegA DS 0217 1.pdf


Contrast Ratio >500:1 pre-pulse, >250:1 post pulse; other pulses >1000:1
Beam Quality (M2) <29 <1.5 <1.3
Autocorrelation of RegA 9040 Pulses
Deconvolved Single-Shot Pulse FWHM = 31 fs
Typical RegA
Output Pulse Energy
1 Assumes full 12W of Verdi…

FT Tech Bull.qxd

FT Tech Bull.qxd

…determine pulse shape information are autocorrelations (intensity or interferometric) or spectral measurements. Autocorrelations suffer from the fact that the autocorrelation function, not the pulse shape is measured and the shape of the resulting autocorrelation is strongly dependent on the pulse…

COHR Hidra DS 0317 2 FINAL.pdf

COHR Hidra DS 0317 2 FINAL.pdf

…factory. A Gaussian pulse shape deconvolution factor (0.7) is used to determine the pulse width from an autocorrelation signal measured with a Coherent Model SSA
Single Shot Autocorrelator. For other pulse width specifications please contact the factory.
5 Measured over 1000 shots under…

Vitesse800 DSrevC

Vitesse800 DSrevC


2 A Gaussian pulse shape de-convolution factor (0.7) is used to determine the pulse width from an autocorrelation signal measured
by a Coherent SSA (Single-Shot Autocorrelator). Vitara-S used as seed laser for Libra-USP-HE+ (all other versions use Vitesse).
3 Contrast ratio is…

COHR Monaco517 DS 0318 4.pdf

COHR Monaco517 DS 0318 4.pdf

Monaco 517 Datasheet
TYPICAL PERFORMANCE DATA
Monaco 517 Sub-350 fs Temporal Profile (Autocorrelator)
Monaco 517 Sample Spatial Mode at 1 MHz
192.1 mm
(7.56 in.)
Air Intake
Feet
82.6 mm
(3.25 in.)
76.2 mm
(3.0 in.)
349.6 mm
(13.77 in.)…

COHR WP PropagationDispersionMeasurement of sub 10fsPulses 08 29 18.pdf

COHR WP PropagationDispersionMeasurement of sub 10fsPulses 08 29 18.pdf

…laser and 6 fs Transform Limit for <8 fs option)
we need to use the proper pulse measurement tool.
Many devices like FROGs, autocorrelators and
SPIDERs are commercially available or home-built,
however not all are suitable to match the repetition rate
and pulse duration…

COHR Monaco1035 DS 0318 5.pdf

COHR Monaco1035 DS 0318 5.pdf

Monaco 1035 Datasheet
TYPICAL PERFORMANCE DATA
Monaco 1035 Sub-350 fs Temporal Profile (Autocorrelator)
Monaco 1035 Sample Spatial Mode at 1 MHz
192.1 mm
(7.56 in.)
Air Intake
Feet
82.6 mm
(3.25 in.)
76.2 mm
(3.0 in.)
349.6 mm
(13.77…

ChameleonUltra DS 16-02-16  F.pdf

ChameleonUltra DS 16-02-16 F.pdf

…Specified at peak of tuning range.
2 Average speed measured over entire tuning range.
3 Based on sech2 deconvolution of 0.65 times autocorrelation width.
4 Measured RMS in a 10 Hz to 20 MHz bandwidth.
5 Power drift in any two-hour period with less than ±1°C temperature change…

ChameleonVision DS 0216 3.pdf

ChameleonVision DS 0216 3.pdf

…Specified at peak of tuning range.
2 Average speed measured over entire tuning range.
3 Based on sech2 deconvolution of 0.65 times autocorrelation width.
4 Measured RMS in a 10 Hz to 20 MHz bandwidth.
5 Power drift in any two-hour period with less than ±1°C temperature change…

COHR ChameleonVision-S DS 0517 3.pdf

COHR ChameleonVision-S DS 0517 3.pdf

…9 kg (20 lbs.)
1 At 800 nm
2 Average speed measured over entire tuning range.
3 Based on sech2 deconvolution of 0.65 times autocorrelation width.
4 Measured RMS in a 10 Hz to 20 MHz bandwidth.
5 Power drift in any two-hour period with less than ±1°C temperature change…

MiraHP DS 2.qxd

MiraHP DS 2.qxd


1 Specifications apply only with Coherent VerdiTM-V18 pump lasers.
2 At 800 nm.
3 Based on sech2 deconvolution of 0.65 times autocorrelation width. Pulse width is <200 fs across specified tuning range in fs
mode.
4 In fs mode, the pulses are typically 1.5x the transform…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.