Search Results

1 - 12 of 27 Products for 'autocorrelator' Page 1 of 3 |

autocorrelator

Microsoft Word - COHR whitepaper whitedwarfmonaco 5 21 2018

Microsoft Word - COHR whitepaper whitedwarfmonaco 5 21 2018


pulse of just a few optical cycles. The actual pulse width has been characterized using a
scanning intensity autocorrelator with a 10 m thick BBO. The autocorrelator trace is shown in
figure 5, revealing 8.6 fs FWHM, assuming a Gaussian pulse. In this mode of operation, the

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…OPerA Solo 66-67
TOPAS 68-69
TOPAS-Prime 70-71
SHBC/TOPAS-400 72-73
Harmonic Generator Systems (HGS) 74
Single-Shot Autocorrelator (SSA) 75
OPA 9400/9450 and 9800/9850 76
DFG 9800/9850 77
Legend Elite CEP 78-79
Laser Measurement and Control Accessories…

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…Opera-HP 66-67
OPerA Solo 68-69
TOPAS-Prime 70-71
SHBC/TOPAS-400 72-73
Harmonic Generator Systems (HGS) 74
Single-Shot Autocorrelator (SSA) 75
OPA 9400/9450 and 9800/9850 76
DFG 9800/9850 77
Legend Elite CEP 78-79
Laser Measurement and Control Accessories…

Legend-Cryo-PA DS

Legend-Cryo-PA DS

…Vitara. A Gaussian pulse shape de-convolution factor (0.7) is used to determine the pulse width
from an autocorrelator signal measured by a Coherent SSA (Single-Shot Autocorrelator). For other seed lasers, please contact factory.
3 Pulse energy is dependent on pre-amplifier performance and…

MiraOPO-X DS 15-09-15  Final.pdf

MiraOPO-X DS 15-09-15 Final.pdf

…m using optional optics sets · Active cavity length stabilization · Built-in diagnostics · Remote service capability Mira OPO-X Options: · Autocorrelator · Idler output · Depleted pump output · Simultaneous access to Signal IR and VIS outputs from ring configuration · Difference frequency generation…

Chameleon-Vision-S-The-Next-Generation-of-One-Box-Ti-Sapphire-Lasers.pdf

Chameleon-Vision-S-The-Next-Generation-of-One-Box-Ti-Sapphire-Lasers.pdf

www.Coherent.com I tech.sales@coherent.com I (800) 527-3786 I (408) 764-4983 3
Figure 2, Autocorrelator trace showing 73 fs pulsewidth
This is also the case with MPE and other non-linear
microscopy modalities, although it should be noted that
an excessive increase in peak power…

LegendEliteDuoHEplus DS 0915revA 7b.pdf

LegendEliteDuoHEplus DS 0915revA 7b.pdf

…pulse width and a deconvolution factor which
is then used to determine the real pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator).
4 Not available in -III pump configuration.
5 When seeded by Vitara. For other seed lasers, please…

Chameleon Vision S whitepaper.pdf

Chameleon Vision S whitepaper.pdf


peak power achieved by decreasing the pulse duration
at constant average power can improve the signal
level.
Figure 2, Autocorrelator trace showing 75 fs pulsewidth
This is also the case with MPE and other non-linear
microscopy modalities, although it should be noted…

LegendEliteHEplus DS 0715revA 6.pdf

LegendEliteHEplus DS 0715revA 6.pdf

…pulse width and a deconvolution factor which
is then used to determine the real pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator).
4 Not available in -I configuration, limited to 4 mJ in -II and 5 mJ in -III configurations.
5 When…

Legend-Elite-HE-Data-Sheet.pdf

Legend-Elite-HE-Data-Sheet.pdf

…pulse width and a deconvolution factor which
is then used to determine the real pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator).
4 Not available in -I configuration, limited to 4 mJ in -II and 5 mJ in -III configurations.
5 When…

COHR Astrella DS 0117 3.pdf

COHR Astrella DS 0117 3.pdf

…shipment.
3 A Gaussian pulse shape de-convolution factor (0.7) is used to determine the pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator).
4 Contrast ratio is defined as the ratio between the peak intensity of the output pulse to the peak…

COHR RegA DS 0217 1.pdf

COHR RegA DS 0217 1.pdf


Contrast Ratio >500:1 pre-pulse, >250:1 post pulse; other pulses >1000:1
Beam Quality (M2) <29 <1.5 <1.3
Autocorrelation of RegA 9040 Pulses
Deconvolved Single-Shot Pulse FWHM = 31 fs
Typical RegA
Output Pulse Energy
1 Assumes full 12W of Verdi…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.