Ask a Question
Coherent

Search Results

37 - 48 of 1438 Products for 'beam diameter' Page 4 of 120 |

beam diameter

(No Title Available)

(No Title Available)

…is available at 355, 460, 480, 488, 514, 532, and 577 nm with up to 4W of output power. The TEM 00 beam parameters remain constant from 10%-100% of the rated power including beam diameter, divergence, and M2. Mode hop-free performance is tested and recorded down to 250 mW with minimized frequency…

Microelectronics

Microelectronics

…when using lens-based objectives. These beam delivery optics can achieve a homogenized spot with a diameter as small as five (5) microns, which is ideal for sampling small fluid inclusions. The optics also include interchangeable circular and square beam shaping masks providing high sampling…

Beam Diag Broch

Beam Diag Broch

…Standards Organization (ISO) standards for laser beam measurement: peak and centroid position of a beam, the beam ellipticity (and angular position of the ellipse and major/minor axes) and circularity, the D4 diameters and widths of the beam (together with slit and knife edge ISO equivalent…

Beam Diag Broch

Beam Diag Broch

…Standards Organization (ISO) standards for laser beam measurement: peak and centroid position of a beam, the beam ellipticity (and angular position of the ellipse and major/minor axes) and circularity, the D4 diameters and widths of the beam (together with slit and knife edge ISO equivalent…

Beam Diag Broch

Beam Diag Broch

…Effective area · Peak-to-average intensity · Beam diameter/widths (selectable): - Second moment (d4Sigma) - Knife edge - Slit - Aperture diameter - Effective diameter · Divergence at % energy/power · Gaussian fits with: - Correlation coefficient - Diameter - Centroid - Peak intensity - Fit roughness…

Beam Diag Broch

Beam Diag Broch

…Effective area · Peak-to-average intensity · Beam diameter/widths (selectable): - Second moment (d4Sigma) - Knife edge - Slit - Aperture diameter - Effective diameter · Divergence at % energy/power · Gaussian fits with: - Correlation coefficient - Diameter - Centroid - Peak intensity - Fit roughness…

Microsoft Word - Understand Different Laser Beam  Rev 1 Final.doc

Microsoft Word - Understand Different Laser Beam Rev 1 Final.doc

…sensor for beam size measurement, a good rule of thumb in the case of round beams is that the beam diameter should be 15 to 20% smaller than the physical size of the array or sensor. In the case of beams that are not round, use the longest dimension for this comparison. In Depth: Laser Beam Size The…

Microsoft Word - Understand Different Laser Beam  Rev 1 Final.doc

Microsoft Word - Understand Different Laser Beam Rev 1 Final.doc

…sensor for beam size measurement, a good rule of thumb in the case of round beams is that the beam diameter should be 15 to 20% smaller than the physical size of the array or sensor. In the case of beams that are not round, use the longest dimension for this comparison. In Depth: Laser Beam Size The…

Microsoft Word - Understand Different Laser Beam  Rev 1 Final.doc

Microsoft Word - Understand Different Laser Beam Rev 1 Final.doc

…sensor for beam size measurement, a good rule of thumb in the case of round beams is that the beam diameter should be 15 to 20% smaller than the physical size of the array or sensor. In the case of beams that are not round, use the longest dimension for this comparison. In Depth: Laser Beam Size The…

Microsoft Word - Understand Different Laser Beam  Rev 1 Final.doc

Microsoft Word - Understand Different Laser Beam Rev 1 Final.doc

…arrays. Beam diameters down to approximately 3 µm can be measured directly and with good accuracy. The main benefit of these systems is that beam expansion is not required to accurately measure extremely small beams. Power (or Energy) of the Beam The power or energy of the beam is another…

Microsoft Word - Understand Different Laser Beam  Rev 1 Final.doc

Microsoft Word - Understand Different Laser Beam Rev 1 Final.doc

…arrays. Beam diameters down to approximately 3 µm can be measured directly and with good accuracy. The main benefit of these systems is that beam expansion is not required to accurately measure extremely small beams. Power (or Energy) of the Beam The power or energy of the beam is another…

Microsoft Word - Understand Different Laser Beam  Rev 1 Final.doc

Microsoft Word - Understand Different Laser Beam Rev 1 Final.doc

…arrays. Beam diameters down to approximately 3 µm can be measured directly and with good accuracy. The main benefit of these systems is that beam expansion is not required to accurately measure extremely small beams. Power (or Energy) of the Beam The power or energy of the beam is another…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions