Search Results

1 - 6 of 6 Products for 'beam expander mount' Page 1 of 1 |
  • 1

beam expander mount

MATRIX-Accessories-Data-Sheet.pdf

MATRIX-Accessories-Data-Sheet.pdf

…to enable optimum performance of the MATRIX lasers. Specifications MATRIX UV MATRIX UV and IR/Green MATRIX IR/Green Mounting Feet, UV 90° Cable Adapter Mounting Feet, IR Kinematic Mounts and Balls, UV Water-Cooling Plate Kit Kinematic Mounts and Balls, IR Beam Expander Mount MATRIX Accessories

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf

…is
especially useful when matching multiple wavelengths into the same beam focus position.
· Adjust the beam at the laser to reduce the need for
expensive and bulky adjustable beam expanders.
Mounting Surface
14.76 mm ±0.13 mm
(0.581 in. ±0.005)
17.5 mm typical…

COHR MATRIX355 DS 0317 2.pdf

COHR MATRIX355 DS 0317 2.pdf

…rack mount
External Control RS-232 interface, TTL QS control
Input Power Requirements
Input Voltage (VAC) 90 to 240, 50 to 60 Hz
Input Power maximum typical
Power Supply (VA) 750 350
1 AVIA Ultra 2000 compatible beam parameters through internal beam expander (BE).…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…install by mounting them on the back
of the sensor.The heat sinks expand the average power handling capability as outlined below. See the Accessories section on
page 94 for more information about heat sinks.
POWER
& ENERGY
Custom
& OEM
BEAM
DIAGNOSTICS…

Chameleon Reliability Antarctia Final WP.pdf

Chameleon Reliability Antarctia Final WP.pdf

…optical mounts,
which contain many separate metal parts including
threaded holes, screws and flexures. In this approach,
the mounts are adjusted to bring the laser into perfect
alignment and locking screws are used to
"permanently" fix the position of each mount. In reality,…

Laser Focus World - August 2016

Laser Focus World - August 2016

…argon laser. In an ironic
additional twist, Sapphire's form factor
meant that its incorporation required engineering--the beam position and mounting scheme was entirely new--so it simply was not a "drop-in" replacement. In
retrospect, had we packaged it to emulate
the ion…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions