Ask a Question
Coherent

Search Results

25 - 36 of 484 Products for 'beam pointing stability' Page 3 of 41 |

beam pointing stability

INNOVA 90C

INNOVA 90C

…- Beam Specifications 2 Argon Krypton Beam Diameter (@ 1/e 2 points)3 1.5 mm 1.5 mm Beam Divergence (full angle) 0.5 mrad 0.8 mrad Beam Waist Diameter 4 1.4 mm 1.1 mm Beam Waist Location 4 1.50 m 1.27 m Cavity Length Single-line 1.16 m 1.16 m Multiline 1.14 m 1.14 m Long Term Power Stability 5 Light…

Azure

Azure

…351 nm and 413 nm wavelength lasers. The Azure features the Sentinel system, an on-board series of automated capabilities that control beam pointing, maintain constant output power at 266 nm, shift the crystal, and relock the cavity. The Sentinel system allows the Azure to operate hands-free…

INNOVA 70C

INNOVA 70C

…0.07 0.07 - - 457.9 0.20 0.30 0.30 - 0.03 Multiline UV - - 0.05 - 0.05 Beam Specifications 2 Argon Krypton Beam Diameter (@ 1/e 2 points)3 1.5 mm 1.5 mm Beam Divergence (full angle) 0.5 mrad 0.8 mrad Long Term Power Stability 4 Light Regulation +/- 0.5% +/- 0.5% Current Regulation +/- 3.0% +/- 3.0%…

RAPID

RAPID

…at 1064 nm and up to 1000 kHz
* Pulse on demand
* Burst mode
* High beam quality M2 >100:1 Beam Divergence, Full Angle (mrad) 85 Beam-Pointing Stability in Full PRF Range (µrad/°C) <50 Electric Supply 100 to 230 VAC/50 to 60 Hz Beam Diameter at 1064 nm (μm) ~1000 750 to 1200 (Laser Head Output) 1500…

INNOVA 300C

INNOVA 300C

…Krypton models optimized for Violet or UV wavelengths
* PowerTrack™ automatic active cavity stabilization for maximum power, best transverse mode, and lowest beam noise
* ModeTrack/ModeTune™ etalon stabilization for mode-hop-free, single-frequency performance over a wide temperature range
* Several…

Graphic Arts & Display

Graphic Arts & Display

…a laser. The quality of a hologram is dependent upon numerous factors including exposure time, laser linewidth, frequency stability, power stability and pointing stability. Minimizing the exposure time is generally desirable since this reduces the effects of the environment (e.g., vibration). Ample…

Beam Diag Broch

Beam Diag Broch

…to the time dependent statistical data extremely easy. Thus, the jitter and stability of parameters, such as power, energy, pointing direction, ellipticity and beam size, etc., can be analyzed along with a polar beam wander plot. The Live Video mode. Characterizing Pulsed Lasers The BeamView…

Beam Diag Broch

Beam Diag Broch

…to the time dependent statistical data extremely easy. Thus, the jitter and stability of parameters, such as power, energy, pointing direction, ellipticity and beam size, etc., can be analyzed along with a polar beam wander plot. The Live Video mode. Characterizing Pulsed Lasers The BeamView…

Designing ProvenHands-free Reliability TechNote FinalWeb.pdf

Designing ProvenHands-free Reliability TechNote FinalWeb.pdf

…design of all opto-mechanical components to make sure every optical mount and assembly well exceeds the required level of stability. Figure 3 shows beam pointing stability data that confirms the success of this approach. These data cover 50 hours of continuous operation of a Vitara-T. The standard…

Designing-and-Manufacturing-fs-Ultra-broadband-Lasers-Proven-Hands-free-Reliability-White-Paper.pdf

Designing-and-Manufacturing-fs-Ultra-broadband-Lasers-Proven-Hands-free-Reliability-White-Paper.pdf

…design of all opto-mechanical components to make sure every optical mount and assembly well exceeds the required level of stability. Figure 3 shows beam pointing stability data that confirms the success of this approach. These data cover 50 hours of continuous operation of a Vitara-T. The standard…

Coherent Whitepaper - Astrella Tisch Sphere FINAL.pdf

Coherent Whitepaper - Astrella Tisch Sphere FINAL.pdf

…Figure 2. The integrated Astrella amplifier is characterized by its low M2 output beam, high pointing stability and low output noise. The inset shows typical near field M2 data. The stability, reliability and beam quality of Astrella were maximized as part of Coherent's ongoing Industrial Revolution…

Coherent Whitepaper - Astrella Tisch Sphere FINAL.pdf

Coherent Whitepaper - Astrella Tisch Sphere FINAL.pdf

…Figure 2. The integrated Astrella amplifier is characterized by its low M2 output beam, high pointing stability and low output noise. The inset shows typical near field M2 data. The stability, reliability and beam quality of Astrella were maximized as part of Coherent's ongoing Industrial Revolution…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions