beam pointing stability

COHR CPC1040 DS 0616 5.pdf

COHR CPC1040 DS 0616 5.pdf

…Chameleon Discovery · Wide range of dispersion control · High power handling and excellent transmission efficiency · Compact · Excellent beam pointing stability CPC 1040 Applications: · Multiphoton Excitation (MPE) Microscopy · Second Harmonic Generation Imaging · Third Harmonic Generation Imaging…

COHR OBIS LG DS 0118 8.pdf

COHR OBIS LG DS 0118 8.pdf

…TEM00
Beam Quality (M2)<1.2
Beam Circularity2 1.0 ± 0.15
Beam Waist Diameter (mm) (FW, 1/e2)<1.2
Beam Divergence (mrad) (FW, 1/e2)<0.5
Beam Waist Location3 (mm) ±500
Beam Pointing (mrad) ±<5.0
Beam Pointing Stability (µrad/°C) <10
Beam Position…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

beam pointing stability
M2 Beam Propagation Analyzer
ModeMaster PC
The ModeMaster PC head is a dual-knife-edge beam profiler
integrated with a diffraction-limited precision scanning lens,
which is translated along the beam propagation axis.The
lens focuses the beam to…

COHR AVIA NX Green DS 0818 3.pdf

COHR AVIA NX Green DS 0818 3.pdf

…Vertical, ±3°
Beam Pointing Stability (µrad/°C) <25
Pulse Energy Stability (%) (RMS) <5
Power Stability (%) (RMS, 2s) (over 8 hours) <2
Warm-up Time (minutes)
Cold Start
Warm Start
<45
<15
Long-term Pointing Stability at Fixed Rep-rate…

COHR AVIA NX UV DS 0117 5.pdf

COHR AVIA NX UV DS 0117 5.pdf

…Vertical, ±3°
Beam Pointing Stability (µrad/°C) <25
Pulse Energy Stability (%) (RMS) <5
Power Stability (%) (RMS, 2s) (over 8 hours) <2
Warm-up Time (minutes)
Cold Start <45
Warm Start <15
Long-term Pointing Stability at Fixed Rep-rate (rad)…

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…Direction3 Vertical ±3°
Beam Pointing Stability (µrad/°C) <25
Pulse Energy Stability (%)(RMS) <2
Power Stability (%)(RMS, 2s) <2
Warm-up Time (minutes)
Cold Start <45
Warm Start <15
Long-term Pointing Stability at Fixed Rep-rate (rad) ±25 over…

COHR HyperRapid50 DS 0716 4.pdf

COHR HyperRapid50 DS 0716 4.pdf

…Power Stability over 8 hours1 (% rms, constant temperature) <1
Polarization Ratio >>100:1
Beam Diameter 2w (x,y) at Output (µm)(typical) 2400 1350 1650 2400 1100 2000
Beam Divergence, Full Angle (mrad) <1
Beam Circularity1 (%) >85
Beam Pointing Stability in…

COHR HyperRapid100 355-SW DS 0716 6.pdf

COHR HyperRapid100 355-SW DS 0716 6.pdf


Average Power Stability over 8 hours (% rms, at 500 kHz) <1 at 1064 nm
Polarization Ratio >>100:1
Beam Diameter (µm)(typical) 2650 2100 2100
Beam Divergence, Full Angle (mrad) <1
Beam Circularity (%) >85
Beam Pointing Stability in Full PRF Range (µrad/°K)…

Quotation KML QGYYMMDD G  Institute Contact

Quotation KML QGYYMMDD G Institute Contact

…computer-assisted automatic laser beam alignment and pointing stabilization system. It also
includes a convenient real-time laser beam parameter monitoring and logging system. The result
is that the pointing stability of the EUV source exceeds the pointing stability performance of the

RAPID-NX-Data-Sheet-06-23-14.pdf

RAPID-NX-Data-Sheet-06-23-14.pdf

Beam Waist Diameter (mm) 1 ±0.2
Beam Waist Location At output port ±25% of RR
Astigmatism ±25% of Rayleigh Range
Ellipticity 0.85 < e < 1.15
Polarization Ratio >100:1
Polarization Direction Vertical ±3° IR
Contrast Ratio4 >100:1
Beam Pointing Stability

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

…(mW) >20
Spatial Mode TEM00
Beam Quality (M2) <1.2
Beam Circularity2 1.0 ±0.15
Beam Waist Diameter (mm)(FW, 1/e2) 1.0 ±0.2
Beam Divergence (mrad)(FW, 1/e2) <1.2
Beam Waist Location3 (mm) ±325
Beam Pointing Stability (rad/°C) <10
Polarization Ratio…

COHR MagnumII DS 1017 3.pdf

COHR MagnumII DS 1017 3.pdf

…optics. In addition, the laser has exceptional beam pointing and focusing stability. The Magnum II has fully protected electronics as well as a bipolar thermoelectric cooler used to keep the laser diode at a constant temperature. The laser beam can be modulated by an external signal and all models…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.