…Utility Requirements
Operating Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply <8 at 90 VAC
Chiller <14 at 90 VAC
MRU <2 at 90 VAC
System Power Consumption (W) 2300
Line Frequency (Hz) 47 to 63
Communications/Control…

Vitara Preinstall.book

Vitara Preinstall.book

…REQUIREMENT MAX. POWER CONSUMPTION
Verdi G-Series Power Supply 100 to 240 VAC 750 VA
Vitara Controller 90 to 250 VAC 110 VA
Water Chiller 90 to 250 VAC 825 VA
Line Frequency 47 to 63 Hz -
Note: All specifications and requirements are subject to change without notice.

COHR HRNX SmartCleave DS 0718 3.pdf

COHR HRNX SmartCleave DS 0718 3.pdf

…>100:1
Warm-up Time from Chiller Start (minutes) <45
Electrical Supply 100 to 230V AC/50 to 60 Hz/2.5 kW
Mounting Orientation Horizontal
Chiller Water-to-Air or Water-to-Water
Dimensions
Laser Head
Power Supply
SMC Chiller
600 x 780 x 245 mm (23.6 x…

COHR HyperRapidNX DS 0618 1.pdf

COHR HyperRapidNX DS 0618 1.pdf

…>100:1
Warm-up Time from Chiller Start (min) <45
Electrical Supply 100 to 230V AC/50 to 60 Hz/2.5 kW
Mounting Orientation Horizontal
Chiller Water-to-Air or Water-to-Water
Dimensions
Laser Head
Power Supply
SMC Chiller
600 x 780 x 245 mm
3U 19"…

COHR Azure DS 0717 4.pdf

COHR Azure DS 0717 4.pdf

…Laser Head Closed-loop chiller for baseplate
Power Supply Air-cooled
Shipping Thermal Requirements -20 to +50°C shipping in a non-condensing environment
Orientation Horizontal ±2°
Power Supply (VAC) 100 to 240
Azure Power Consumption (kW) 1
Chiller Power Consumption…

UCLD Catalog.book

UCLD Catalog.book

…laser head, power supply, and chiller layout; FAP
assembly replacement; performing output power calibration; limited troubleshooting techniques; desiccant
chamber(s) removal and replacement; Brewster window cleaning; head, power supply, and chiller swaps; RS-232
operation; modem…

00 Laser Cooling.book

00 Laser Cooling.book

…match the operating requirements of
ion lasers. Details are given in Appendix A: Coherent Cooling
Options.
Closed-Loop
Chiller
Chillers have many of the same advantages of heat exchangers
insofar as a fixed volume of water is recirculated through the laser.
Unlike…

COHR ChameleonVision-S DS 0517 3.pdf

COHR ChameleonVision-S DS 0517 3.pdf

…(73 lbs.)
Umbilical Length 3 m (10 ft.)
Dimensions (L x W x H)
Chiller 436 x 270 x 393 mm (17.17 x 10.63 x 15.47 in.)
MRU Air Recirculator 46 x 43 x 8.5 cm (18 x 17 x 3 in.)
Weight
Chiller 11 kg (25 lbs.)
MRU Air Recirculator: 9 kg (20 lbs.)
1 At 800 nm

PaladinAdvanced355 DS

PaladinAdvanced355 DS

…(19 x 7 x 19.9 in.), 19 in., rack-mountable
Chiller 482 x 177 x 560 mm (19 x 7 x 22 in.), 19 in., rack-mountable
Pump Fiber's Length 5m (16.4 ft.)
Weights
Laser Head 50 kg (110 lbs.)
Power Supply 30 kg (66 lbs.)
Chiller 38 kg + 3 liters coolant (84 lb. + 0.7 gal.)

COHR FidelityHP DS 0117 2.pdf

COHR FidelityHP DS 0117 2.pdf

…Power Supply 19" rack mount
Electrical Requirements (VAC) 100 to 250, 50 to 60 Hz
Cooling Requirements
Air-cooled closed-loop chiller (included)
External Interfaces RS-232, USB, Sync Out
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature (°C) 15 to 35
Non-operating…

COHR ChameleonDiscovery TPC DS 1117 5.pdf

COHR ChameleonDiscovery TPC DS 1117 5.pdf

…Total Power Control
Operating Voltage (VAC) 90 to 250 (auto ranging)
Maximum Operating Current (A)
Power Supply <8 at 90 VAC
Chiller <14 at 90 VAC
MRU <2 at 90 VAC
System Power Consumption (W) 2300
Line Frequency (Hz) 47 to 63
Communications/Control…

COHR MephistoMOPA DS 0417 2.pdf

COHR MephistoMOPA DS 0417 2.pdf

…Temperature4 (°C) 25
Cooling Power2 (W) (chiller) 300 to 600
Options Frequency doubled MOPA version available upon request
1 Measured at constant room temperature.
2 Depending on model.
3 Non-deionized water recommended. Chiller available upon request.
4 Operation above…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.