Search for Lasers, Laser Systems, Laser Measurment, Laser Service Coherent Inc., Worldwide websites Coherent Inc., calendar of events Coherent Inc., office locator Coherent Inc., Service Centers
     > Search
Search Coherent
Coherent Inc.
Superior Reliability & Performance
  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
Please enter a search phrase.

1 - 10 of 58 Search Results for chirp
Search Suggestions: chameleon | femtosecond laser system | two photon | ultrafast lasers | ti sapphire laser | mantis | glasgow | sapphire | yag laser | positive light

1pdf document  FemtosecondRev2 Best match in this PDF  |  All matches in this PDF
... components of the pulse travel at different speeds. As a result, pulsewidth is lengthened (see Fig. 2). This process is sometimes referred to as chirping. The pulsewidth at the sample is a combination of the starting pulsewidth and the amount of GVD stretching, which is proportional to the spectral ...
Related Searches: chameleon | femtosecond laser system | two photon

2pdf document  Custom_Laser_Brochure Best match in this PDF  |  All matches in this PDF
... system, designed to your specifications. Positive Light offers: · The most experienced custom laser team in the industry · Technical expertise in chirped pulse amplification, relay imaging, and temporal pulse shaping · Fast and reliable switching and synchronization electronics · The highest peak power ...
Related Searches: yag laser | positive light | thermal detector | nd yag

3pdf document  UCLD_Catalog_Customer  (PAGE 24 OF 40)
... : Laser and electrical safety, Review of specifications and typical operating conditions, Laser basics, Theory of operation including the concept of Chirped Pulse Amplification, Review of optical beam paths, Demonstration of alignment optimization, System optimization, Maintenance procedures, Optics ...
Related Searches: coherent mira 900

4pdf document  OLEReprintCoherentMay06  (PAGE 1 OF 3)
... figure 1). But in real world ultrafast laser systems, this transform limit is rarely reached. Even if it is reached within the laser, the pulse is chirped (stretched) to some degree by subsequent beam delivery optics before it reaches the interaction zone of the experiment as a result of GVD. GVD refers ...

5pdf document  OLEReprintCoherentMay06  (PAGE 2 OF 3)
... dispersion stretcher. This type of stretcher laterally spreads the pulse as a function of wavelength and then recombines it in a way that does not chirp the pulse. In the middle of the stretcher, at the so-called Fourier plane, the beam is parallel (collimated) with a linear mapping of wavelength to ...
Related Searches: miips

6Ultrafast Oscillator Accessories
... 9.5 kHz to 4.75 MHz. Pulse Switch Cavity Dumper Accessory for Mira 900. Pulse Compressors Two solutions for GVD compensation: A CPC that is based on chirped mirror technology, and SPO-1 and SPO-2 that are based on prism setups. Synchro-lock AP Accessory to synchronize two Mira lasers or two Micra lasers ...
Related Searches: mira900 | cavity dump | compressor | fluorescence

7Ultrafast Oscillators and Amplifiers
... 9.5 kHz to 4.75 MHz. Pulse Switch Cavity Dumper Accessory for Mira 900. Pulse Compressors Two solutions for GVD compensation: A CPC that is based on chirped mirror technology, and SPO-1 and SPO-2 that are based on prism setups. Synchro-lock AP Accessory to synchronize two Mira lasers or two Micra lasers ...
Related Searches: sapphire laser | hurricane | cavity dump | opo laser

8pdf document  tech_bullfourier_transform  (PAGE 1 OF 2)
Chirped Pulses and the Meaning of Fourier Transform Limited One of the biggest problems associated with ultrashort pulse lasers stems from the fact that in many cases, characterizing the pulse shape is more difficult than generating the pulses. Most researchers would like to know the functional form ...

9pdf document  LegendF_DSrevC  (PAGE 2 OF 2)
... stable environmental conditions. 6 Assuming gaussian pulse shape. For more information on transform-limited pulses, see our Technical Note,"Chirped Pulses and the Meaning of Fourier Transform Limited" at www.coherent.com in the "Literature & Documentation" section on the Legend ...

10pdf document  tech_bullfourier_transform  (PAGE 2 OF 2)
In summary, if it is important to check that your pulse is truly chirp free, simply measuring the TBP can lead to inconclusive and possibly misleading results. If any questions arise during your research, don't hesitate to contact Positive Light for expert technical assistance in all branches of ultrafast ...


Page 1 2 3 4 5 6 of 6 | Next