Search Results

1 - 12 of 25 Products for 'dispersion compensation' Page 1 of 3 |

dispersion compensation

Chameleon-Peak-Power-White-Paper.pdf

Chameleon-Peak-Power-White-Paper.pdf

dispersion compensation. Laser power and detection gain are kept constant but
GDD setting are varied for A: 0 fs2, B:10000 fs2 and C: 15000 fs2. 840 nm imaging of CY3 labelled Glial cells coutesy of Grenoble Institute
of Neuroscience.
Figure 5 Negative GDD
curves for dispersion

WP ChameleonPeakPower Final.pdf

WP ChameleonPeakPower Final.pdf

dispersion compensation. Laser power and detection gain are kept constant but
GDD setting are varied for A: 0 fs2, B:10000 fs2 and C: 15000 fs2. 840 nm imaging of CY3 labelled Glial cells coutesy of Grenoble Institute
of Neuroscience.
Figure 5 Negative GDD
curves for dispersion

COHR ChameleonVision-S DS 0517 3.pdf

COHR ChameleonVision-S DS 0517 3.pdf

…Vision-S Datasheet
Chameleon Vision-S Dispersion Compensation Range
Chameleon Vision-S Peak Power (typical)
Chameleon Vision-S Average Power (typical)
Chameleon Vision-S Pulse Duration (typical)
Wavelength (nm)
Negative Dispersion (fs2)
0
50,000
40,000…

Chameleon-MPX-Data-Sheet.pdf

Chameleon-MPX-Data-Sheet.pdf

…generation fan-poled OPO technology, the fully automated Chameleon MPX delivers high peak power to the sample plane with short pulses and dispersion compensation optimized for typical commercial microscope systems. Featuring a wide pump tuning range, the Chameleon MPX offers independently tunable…

Femtosecond lasers for life science.pdf

Femtosecond lasers for life science.pdf

…fan-poled OPO technology, the fully automated
Chameleon MPX delivers high peak power to the sample plane with short pulses
and dispersion compensation optimized for typical commercial microscope systems.
Featuring a wide pump tuning range, the Chameleon MPX offers independently

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf

Lasers-for-Life-Sciences-Product-Guide FORMFIRST.pdf


Features
· Performance optimized for non-linear imaging applications
· 130 fs short pulses for high peak power
· GDD dispersion compensated output
· Automated, gap-free tuning from 680 nm to 1340 nm with Chameleon pump laser
· Independent wavelength tuning of both laser…

COHR Fidelity-2 DS 0618 4.pdf

COHR Fidelity-2 DS 0618 4.pdf

…(%) <10
Polarization Horizontal
Group Delay Dispersion (GDD) Pre-compensation Range (fs2) -30,000 to 0
FEATURES
Light-loop Power Stabilization
Integrated and Automated Pre-Chirp Dispersion Compensation
Fast Photodiode Output (trigger signal)
ELECTRICAL…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…>500:1
Noise1,3 (%) <0.5
Power Stability4 (%) ±1
Tuning Speed5 (nm/s) >50
Pointing Accuracy (rad)6 <350
Dispersion Compensation Range (fs2)
680 nm 0 to 45,000
800 nm 0 to 25,000
1050 nm 0 to 10,000
1300 nm 0 to 8000
Optical Output B

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…>500:1
Noise1,3 (%) <0.5
Power Stability4 (%) ±1
Tuning Speed5 (nm/s) >50
Pointing Accuracy (rad)6 <350
Dispersion Compensation Range (fs2)
680 nm 0 to 45,000
800 nm 0 to 25,000
1050 nm 0 to 10,000
1300 nm 0 to 8000
Optical Output B

COHR ChameleonDiscovery TPC DS 1117 5.pdf

COHR ChameleonDiscovery TPC DS 1117 5.pdf


Noise1,3 (%) <0.5
Power Stability4 (%) ±1
Tuning Speed5 (nm/s) >50
Pointing Accuracy6 (µrad) <350
Dispersion Compensation Range (fs2)
680 nm 0 to 45,000
800 nm 0 to 25,000
1050 nm 0 to 10,000
1300 nm 0 to 8000
OPTICAL OUTPUT B

ChameleonVision DS 0216 3.pdf

ChameleonVision DS 0216 3.pdf

…design · Ultrawide tuning range (400 nm) · Automated dispersion precompensation in a single box · Fully-controllable dispersion precompensation down to 0 at all wavelengths · High output power (up to >3W) · Ultra wide dispersion compensation range from 0 to >45,000 fs2 · Simple menu-driven GUI or…

Mira brochure

Mira brochure

…configurations. These include:
Mira Optima 900-F.
The Mira Optima 900-F operates in femtosecond
mode, with GVD (Group Velocity Dispersion) compensation achieved via an elegant, double-pass,
two-prism sequence at the rear of the cavity.
Mira Optima 900-P.
The Mira Optima…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions