37 - 48 of 586 Products for 'energy max' Page 4 of 49 |

energy max

LDP-200MQU-HP

LDP-200MQU-HP

…Linear Q-switched performance Frequency 7.5 kHz 10
* kHz 15 kHz 20 kHz 50 kHz Average Power 50 Watts 55
* Watts 50 Watts 45 Watts 45 Watts Pulse Energy 6.7 mJ 5.5
* mJ 3.3 mJ 2.25 mJ 0.9 mJ Pulse Width ≤ 90 ns ≤ 100
* ns ≤ 140 ns ≤ 170 ns ≤ 180 ns Peak Pulse Power ≤ 74.1 kW ≤ 55.0
* kW ≤ 23.8 kW ≤…

LDP-200MQU-HP-Dual

LDP-200MQU-HP-Dual

…Linear Q-switched performance Frequency 7.5 kHz 10
* kHz 15 kHz 20 kHz 50 kHz Average Power 90 Watts 100
* Watts 100 Watts 90 Watts 90 Watts Pulse Energy 12 mJ 10
* mJ 6.7 mJ 4.5 mJ 1.8 mJ Pulse Width ≤ 110 ns ≤ 120
* ns ≤ 140 ns ≤ 180 ns ≤ 180 ns Peak Pulse Power ≤ 109 kW ≤ 91
* kW ≤ 48 kW ≤ 25 kW ≤ 10…

Fiber Coupling Unit

Fiber Coupling Unit

…sensors for improved supervising. The unit is easily integrated to the laser. Tech spec Max. power (CW) 4.5 kW Focal lengths 50, 60, 70, 85, 100 mm Max. collimated beam Ø18 mm (incl. 99% of the beam energy) Optics material Synthetic fused silica AR-coatings 1030-1090 nm, 780-1100 nm, 510-550 nm…

COHR ExcimerCatalog2016revC.pdf

COHR ExcimerCatalog2016revC.pdf

Superior Reliability & Performance · www.Coherent.com · tech.sales@coherent.com4 Wavelength Max. Energy Max. Repetition Rate ExciStar XS (nm) (mJ) (Hz) 157 2 500 193 10 500 248 12 500 351 5 500 IndyStar1 193 8 1000 193 4 2000 248 12 1000 248 6 2000 COMPexPro COMPexPro 50 193 100 50 248 150 50…

COHR ExcimerCatalog2016revA 1.pdf

COHR ExcimerCatalog2016revA 1.pdf

Superior Reliability & Performance · www.Coherent.com · tech.sales@coherent.com4 Wavelength Max. Energy Max. Repetition Rate ExciStar XS (nm) (mJ) (Hz) 157 2 500 193 10 500 248 12 500 351 5 500 IndyStar1 193 8 1000 193 4 2000 248 12 1000 248 6 2000 COMPexPro COMPexPro 50 193 100 50 248 150 50…

COHR ExcimerCatalog2016revC.pdf

COHR ExcimerCatalog2016revC.pdf

Superior Reliability & Performance · www.Coherent.com · tech.sales@coherent.com4 Wavelength Max. Energy Max. Repetition Rate ExciStar XS (nm) (mJ) (Hz) 157 2 500 193 10 500 248 12 500 351 5 500 IndyStar1 193 8 1000 193 4 2000 248 12 1000 248 6 2000 COMPexPro COMPexPro 50 193 100 50 248 150 50…

COHR ExcimerCatalog2016revA 1.pdf

COHR ExcimerCatalog2016revA 1.pdf

Superior Reliability & Performance · www.Coherent.com · tech.sales@coherent.com4 Wavelength Max. Energy Max. Repetition Rate ExciStar XS (nm) (mJ) (Hz) 157 2 500 193 10 500 248 12 500 351 5 500 IndyStar1 193 8 1000 193 4 2000 248 12 1000 248 6 2000 COMPexPro COMPexPro 50 193 100 50 248 150 50…

COHR ExcimerCatalog2016revA 1.pdf

COHR ExcimerCatalog2016revA 1.pdf

Superior Reliability & Performance · www.Coherent.com · tech.sales@coherent.com4 Wavelength Max. Energy Max. Repetition Rate ExciStar XS (nm) (mJ) (Hz) 157 2 500 193 10 500 248 12 500 351 5 500 IndyStar1 193 8 1000 193 4 2000 248 12 1000 248 6 2000 COMPexPro COMPexPro 50 193 100 50 248 150 50…

COHR ExcimerCatalog2016revC.pdf

COHR ExcimerCatalog2016revC.pdf

Superior Reliability & Performance · www.Coherent.com · tech.sales@coherent.com4 Wavelength Max. Energy Max. Repetition Rate ExciStar XS (nm) (mJ) (Hz) 157 2 500 193 10 500 248 12 500 351 5 500 IndyStar1 193 8 1000 193 4 2000 248 12 1000 248 6 2000 COMPexPro COMPexPro 50 193 100 50 248 150 50…

COHR ExcimerCatalog2016revC.pdf

COHR ExcimerCatalog2016revC.pdf

· Toll Free: (800) 527-3786 · Tel: (408) 764-4983 · Fax: (800) 362-1170 5 Wavelength Max. Energy Max. Repetition Rate LPXpro Series (nm) (mJ) (Hz) LPFpro 205 157 50 50 LPFpro 220 157 40 200 LPXpro 210 193 300 100 248 700 100 308 450 100 351 200 100 LPXpro 220 193 250 200 248 400 200 308 275 200…

COHR ExcimerCatalog2016revA 1.pdf

COHR ExcimerCatalog2016revA 1.pdf

· Toll Free: (800) 527-3786 · Tel: (408) 764-4983 · Fax: (800) 362-1170 5 Wavelength Max. Energy Max. Repetition Rate LPXpro Series (nm) (mJ) (Hz) LPFpro 205 157 50 50 LPFpro 220 157 40 200 LPXpro 210 193 300 100 248 700 100 308 450 100 351 200 100 LPXpro 220 193 250 200 248 400 200 308 275 200…

COHR ExcimerCatalog2016revC.pdf

COHR ExcimerCatalog2016revC.pdf

· Toll Free: (800) 527-3786 · Tel: (408) 764-4983 · Fax: (800) 362-1170 5 Wavelength Max. Energy Max. Repetition Rate LPXpro Series (nm) (mJ) (Hz) LPFpro 205 157 50 50 LPFpro 220 157 40 200 LPXpro 210 193 300 100 248 700 100 308 450 100 351 200 100 LPXpro 220 193 250 200 248 400 200 308 275 200…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions