Ask a Question
Coherent
Search Results
1 - 12 of 433 Products for 'external trigger' Page 1 of 37 |

external trigger

Book.book

Book.book

…49 External Trigger Edge Select This command selects the external trigger edge. The selected trigger edge is the external trigger event. Command: TRIGger:SLOPe {DEFault|POSitive|NEGative} Default: POSitive Query: TRIGger:SLOPe? Reply: POSitive|NEGative Delay This command selects the external trigger

LabMax-Pro SSIM User Manual

LabMax-Pro SSIM User Manual

…(included). External Trigger Input To prevent ground loop noise from interfering with accurate measurement, the external SMB trigger input is optically isolated from the LabMax-Pro internal ground by an optoisolator. The following figure shows a simplified schematic of the external trigger input…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…TOPICS In this section: · Understanding the external trigger circuit (this page) · Extending cable length (p. 5-2) Understanding the External Trigger Circuit To prevent ground loop noise from interfering with accurate measurement, the external trigger input is optically isolated from the EnergyMax…

Book.book

Book.book

…49 External Trigger Edge Select This command selects the external trigger edge. The selected trigger edge is the external trigger event. Command: TRIGger:SLOPe {DEFault|POSitive|NEGative} Default: POSitive Query: TRIGger:SLOPe? Reply: POSitive|NEGative Delay This command selects the external trigger

Book.book

Book.book

…49 External Trigger Edge Select This command selects the external trigger edge. The selected trigger edge is the external trigger event. Command: TRIGger:SLOPe {DEFault|POSitive|NEGative} Default: POSitive Query: TRIGger:SLOPe? Reply: POSitive|NEGative Delay This command selects the external trigger

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…TOPICS In this section: · Understanding the external trigger circuit (this page) · Extending cable length (p. 5-2) Understanding the External Trigger Circuit To prevent ground loop noise from interfering with accurate measurement, the external trigger input is optically isolated from the EnergyMax…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…TOPICS In this section: · Understanding the external trigger circuit (this page) · Extending cable length (p. 5-2) Understanding the External Trigger Circuit To prevent ground loop noise from interfering with accurate measurement, the external trigger input is optically isolated from the EnergyMax…

LabMax-Pro SSIM User Manual

LabMax-Pro SSIM User Manual

…(included). External Trigger Input To prevent ground loop noise from interfering with accurate measurement, the external SMB trigger input is optically isolated from the LabMax-Pro internal ground by an optoisolator. The following figure shows a simplified schematic of the external trigger input…

LabMax-Pro SSIM User Manual

LabMax-Pro SSIM User Manual

…(included). External Trigger Input To prevent ground loop noise from interfering with accurate measurement, the external SMB trigger input is optically isolated from the LabMax-Pro internal ground by an optoisolator. The following figure shows a simplified schematic of the external trigger input…

Book.book

Book.book

…required by the external trigger pulse. To turn on the optoisolator LED, the external trigger source must be capable of sourcing at least 5 mA at a minimum of 2 VDC into the external trigger input. If the trigger source is not capable of sourcing these minimum values, the trigger source will need…

Book.book

Book.book

…required by the external trigger pulse. To turn on the optoisolator LED, the external trigger source must be capable of sourcing at least 5 mA at a minimum of 2 VDC into the external trigger input. If the trigger source is not capable of sourcing these minimum values, the trigger source will need…

Book.book

Book.book

…required by the external trigger pulse. To turn on the optoisolator LED, the external trigger source must be capable of sourcing at least 5 mA at a minimum of 2 VDC into the external trigger input. If the trigger source is not capable of sourcing these minimum values, the trigger source will need…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions