to the infrared, from nW to kW. Built-in wavelength compensation ensures that readings at any wavelength will remain accurate. This meter provides an economical way to perform laser power measurements and laser tuning. Specifications Max. Measurable Power (with thermopile sensor) 29.9 kW Max.

FieldMaxII-TOP

FieldMaxII-TOP

…Full-Scale Power Ranges (with optical sensor) 3.000 uW to 300.0 mW (auto or manual ranging, selectable) Displayable Full-Scale Energy Range (with pyroelectric sensor) 3.000 nJ to 300.0J (manual ranging) Measurement Resolution 0.1% of full scale Max. Rep. Rate (pulsed energy measurement) 300 Hz…

FieldMaxII-TO

FieldMaxII-TO

…Specifications Max. Measurable Power (with thermopile sensor) 30.0 kW Max. Measurable Power (with optical sensor) 300.0 mW Min. Measurable Power (with thermopile sensor) 10 µW Min. Measurable Power (with optical sensor) 1 nW Displayable Full-Scale Power Ranges (with thermopile sensor) 3.000 mW to

FieldMaxII-TO User Manual

FieldMaxII-TO User Manual

…easy-to-use digital power meter designed for field service and
production applications.
In this section:
· Front panel (p. 3-2)
· Right side panel (p. 3-4)
· Left side panel (p. 3-5)
There are also instructions on how to replace the alkaline batteries
(p. 3-5) and…

FieldMaxII-P

FieldMaxII-P

…batteries Specifications Max. Measurable Energy (with pyroelectric sensor) 300.0J Min. Measurable Energy (with pyroelectric sensor) 1 nJ Displayable Full-Scale Energy Range (with pyroelectric sensor) 3.000 nJ to 300.0J (manual ranging) Measurement Resolution 0.1% of full scale Max. Rep. Rate (pulsed…

Europhotonics - Autumn 2017

Europhotonics - Autumn 2017

…performance
and reliability to match the needs of both
research and commercial applications."
The longer wavelengths emitted from
ytterbium fiber-based lasers is supporting
some of the latest research in threephoton excitation, particularly in the field
of neuroscience.…

COHR DIAMOND E-1000 DS 0817 1.pdf

COHR DIAMOND E-1000 DS 0817 1.pdf


RADIATION. AVOID EYE OR SKIN EXPOSURE
TO DIRECT OR SCATTERED RADIATION.
CLASS 4 LASER PRODUCT PER EN
IEC60825-1:2007/EN60825-1:2007
635 nm to 670 nm VISIBLE (1 mW)
9.1 µm to 10.8 µm INVISIBLE
2000W MAX. AVG. 6J MAX. 1 ms PULSE
471 mm
(18.6 in.)
120…

COHR DiamondCx-10LDE Plus DS 0618 1a.pdf

COHR DiamondCx-10LDE Plus DS 0618 1a.pdf


Altitude
Humidity
5°C to 45°C (41 to 113 °F)
2000 m (6500 ft)
Non-condensing 95%
Shipping/Storage Environment -10°C to +60°C (14 to 140°F), Non-condensing
Coolant
Coolant Flow Rate
Maximum Coolant Pressure
Max. Pressure Differential (at 1.5 gpm)

FieldMaxII-TOP User Manual

FieldMaxII-TOP User Manual

…digital power/energy meter designed for field service
and production applications.
In this section:
· Front panel (p. 3-2)
· Right side panel (p. 3-4)
· Left side panel (p. 3-5)
There are also instructions on how to replace the alkaline batteries
(p. 3-5)…

VarioLas UV material processing | Coherent

VarioLas UV material processing | Coherent

Field Geometry Square Square Line Substrate Field Size (mm 2) 2 x 2 2 x 2 50 x 0.6 Optical Resolution (μm) 30 5 - Working Distance (mm) 50 50 150 Max. Repetition Rate (Hz) 100 100 100 Max. Energy Density (mJ/cm 2) at 193 nm 1000 1000 230 Max. Energy Density (mJ/cm 2) at 248 nm 3500 3500 600 Max.

UW Series 09-19-14 .cdr

UW Series 09-19-14 .cdr

…UW-150 RT Rotary
Height: 76" Height: 70"
Width: 68" Width: 32"
Depth: 38.0" Depth: 60.0"
Work Envelope: XYZ, 30" x 30" x 19"
Max distance between base plate and
galvo box: 22"
Standard Features for all UW models:
! Manual Z axis, internal adjustment
! 3…

Bio Photonics - April 2018

Bio Photonics - April 2018

…wellpublicized field of neuroscience, and these are often amply served with traditional titanium:sapphire (Ti:S) ultrafast lasers. Gabriele Bixel and colleagues at the Max Planck Institute for Molecular Biomedicine in Muenster, Germany, are using multiphoton microscopy at two wavelengths to unravel…

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions