Ask a Question
Coherent
Search Results
13 - 24 of 82 Products for 'field max ii' Page 2 of 7 |

field max ii

IndyStar DS

IndyStar DS

…Array (LAH2) H Condenser Lens (CLLA) I Homogenizer Array (SAH1) J Homogenizer Array (SAH2) K Condenser Lens (CLSA) L Field Lens (FL) M Slit Mask N CCD Camera Alignment Tool O Field Curvature Correction Lens (FCCL) P Projection Lens Doublet Q Beam Profiler CCD Camera and Power Meter R Substrate…

COHR DIAMOND E-1000 DS 0817 1.pdf

COHR DIAMOND E-1000 DS 0817 1.pdf

…6J MAX. 1 ms PULSE 471 mm (18.6 in.) 120 mm (4.7 in.) 203 mm (8.0 in.) 1497 mm (58.9 in.) 1436 mm (56.5 in.) 203 mm (8.0 in.) 384 mm (15.1 in.) 384 mm (15.1 in.) Output Aperture Output Beam 203 mm (8.0 in.) Min. Clearance Required for RFPS Removal 3X Mounting Points Enables "Golden Axis" Rapid Field

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf

2011-Diode-Laser-Modules-and-Pattern-Generators-Catalog.pdf

…to 500 MHz <1.0% Power Stability (8 hours, ±3°C) <_±2% Long-Term Output Power Average <_3%/1000 hrs. Warm-Up Time (minutes) <5 Spatial Mode (far field) TEMoo Pointing Stability (rad/°C) - <6 - <6 Polarization Ratio3 Minimum 100:1 Tolerances4 Beam Position (mm) - <_0.5 - <_0.5 Beam Angle (mrad) -…

Fidelity-2-Data-Sheet.pdf

Fidelity-2-Data-Sheet.pdf

…Compensation · Fast Photodiode Output (trigger signal) · Electrical and Cooling Requirements Voltage 100 to 240 Current Max. (A) 3 Line Frequency (Hz) 50 to 60 Cooling Air-cooled Max. Heat Dissipation from Laser Head (W) 25 Laser Head Dimensions (L x W x H) 317.5 x 317.5 x 127 mm (12.5 x 12.5 x 5.0…

IndyStar DS

IndyStar DS

…Array (LAH2) H Condenser Lens (CLLA) I Homogenizer Array (SAH1) J Homogenizer Array (SAH2) K Condenser Lens (CLSA) L Field Lens (FL) M Slit Mask N CCD Camera Alignment Tool O Field Curvature Correction Lens (FCCL) P Projection Lens Doublet Q Beam Profiler CCD Camera and Power Meter R Substrate…

FieldMaxII-TO User Manual

FieldMaxII-TO User Manual

Description 3 - 1 SECTION THREE: DESCRIPTION Thank you for purchasing the FieldMaxII-TOTM--a versatile, easy-to-use digital power meter designed for field service and production applications. In this section: · Front panel (p. 3-2) · Right side panel (p. 3-4) · Left side panel (p. 3-5) There are…

Book.book

Book.book

…the reported error. Only the first command in error is reported. Table 3-13. VAL$ Format Field Contents 1 Integer time tag in internal timing units of 10 ms 2 Measurement in currently selected units (max. of 8 characters, including a decimal point or other text mirroring the display) Table 3-14.…

IndyStar DS

IndyStar DS

…Array (LAH2) H Condenser Lens (CLLA) I Homogenizer Array (SAH1) J Homogenizer Array (SAH2) K Condenser Lens (CLSA) L Field Lens (FL) M Slit Mask N CCD Camera Alignment Tool O Field Curvature Correction Lens (FCCL) P Projection Lens Doublet Q Beam Profiler CCD Camera and Power Meter R Substrate…

UW Series 09-19-14 .cdr

UW Series 09-19-14 .cdr

…UW-180 Dimensions, UW-150 RT Rotary Height: 76" Height: 70" Width: 68" Width: 32" Depth: 38.0" Depth: 60.0" Work Envelope: XYZ, 30" x 30" x 19" Max distance between base plate and galvo box: 22" Standard Features for all UW models: ! Manual Z axis, internal adjustment ! 3 ports for fume extraction…

Book.book

Book.book

…the reported error. Only the first command in error is reported. Table 3-13. VAL$ Format Field Contents 1 Integer time tag in internal timing units of 10 ms 2 Measurement in currently selected units (max. of 8 characters, including a decimal point or other text mirroring the display) Table 3-14.…

Europhotonics - Autumn 2017

Europhotonics - Autumn 2017

…wavelengths emitted from ytterbium fiber-based lasers is supporting some of the latest research in threephoton excitation, particularly in the field of neuroscience. For the same fluorophores used in two-photon excitation, this represents a 50 percent increase in laser wavelength, which is allowing…

FieldMaxII-TO User Manual

FieldMaxII-TO User Manual

Description 3 - 1 SECTION THREE: DESCRIPTION Thank you for purchasing the FieldMaxII-TOTM--a versatile, easy-to-use digital power meter designed for field service and production applications. In this section: · Front panel (p. 3-2) · Right side panel (p. 3-4) · Left side panel (p. 3-5) There are…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions