fieldmax

00 FieldMax.book

00 FieldMax.book

FieldMax-P User Manual viii 4. Right Side Panel.........................................................................................13 5. Left Side Panel...........................................................................................14 6. Battery…

00 FieldMax.book

00 FieldMax.book

FieldMax-P User Manual 2 Operate the meter only within the specified voltage range. Do not apply a voltage outside the specified range of the input connections. Do not operate the meter if there are suspected failures. Refer damaged units to qualified Coherent service personnel.

00 FieldMax.book

00 FieldMax.book

Description 13 Right Side Panel The right side panel contains the USB and Sensor connections (refer to Figure 4). USB Connector Attaching the cable--shipped with the meter--to this standard USB connector allows communication between FieldMax-P and a computer with a USB interface. Sensor Connector…

00 FieldMax.book

00 FieldMax.book

Description 15 Battery Replacement FieldMax-P uses six 1.5 V alkaline batteries, or a 90-to-260 VAC, 50/60 Hz AC adapter (refer to "AC Adapter" on page 16 for more information about the adapter). Figure 6 illustrates how to replace the batteries. Figure 6. Battery Replacement

00 FieldMax.book

00 FieldMax.book

FieldMax-P User Manual 20 Zone Indicator Bars Zone indicator bars are a series of six segments, as shown in Figure 9: These bars act as visual indicators while the tuning needles automatically move through zones, and also provide a relative indication of where the measurement falls within the active…

00 FieldMax.book

00 FieldMax.book

FieldMax-P User Manual 32 FieldMax-P uses the "3's" Rule--a display formatting rule in which the display value is not allowed to exceed 3, 30, or 300, depending on where the decimal point falls with the decimal point located in a fixed position, as determined by the current range. Typically if a…

00 FieldMax.book

00 FieldMax.book

FieldMax-P User Manual 44 Detailed instructions on how to prepare a product for shipping are shown under "Product Shipping Instructions" on page 45. Table 3. Coherent Service Centers LOCATION PHONE FAX E-MAIL USA 1.800.343.4912 971.327.2778 info_service@coherent.com Europe +49 (6071) 9680…

00 FieldMax.book

00 FieldMax.book

FieldMax-TOP User Manual 2 Operate the meter only within the specified voltage range. Do not apply a voltage outside the specified range of the input connections. Do not operate the meter if there are suspected failures. Refer damaged units to qualified Coherent service personnel.

00 FieldMax.book

00 FieldMax.book

Description 17 Right Side Panel The right side panel contains the USB and Sensor connections (refer to Figure 7). USB Connector Attaching the cable--shipped with the meter--to this standard USB connector allows communication between FieldMax-TOP and a computer with a USB interface. Sensor Connector…

00 FieldMax.book

00 FieldMax.book

Description 19 Battery Replacement FieldMax-TOP uses six 1.5 V alkaline batteries, or a 90-to-260 VAC, 50/60 Hz AC adapter (refer to "AC Adapter" on page 20 for more information about the adapter). Figure 9 illustrates how to replace the batteries. Figure 9. Battery Replacement

00 FieldMax.book

00 FieldMax.book

FieldMax-TOP User Manual 24 Zone Indicator Bars Zone indicator bars are a series of six segments, as shown in Figure 12: These bars act as visual indicators while the tuning needles automatically move through zones, and also provide a relative indication of where the measurement falls within the…

00 FieldMax.book

00 FieldMax.book

FieldMax-TOP User Manual 28 ATTEN The ATTEN annunciator indicates if attenuation correction is applied to the measurement value. "ATTEN" displays whenever attenuation is active. Battery The Battery annunciator flashes whenever the batteries need to be replaced. The Battery annunciator only appears…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.