fieldmaxii-p

FieldMaxII-P User Manual

FieldMaxII-P User Manual

…connected to it. Except for replaceable batteries--discussed under "Battery Replacement" (p. 3-5)--there are no user-serviceable parts in the FieldMaxII-P meter. For service information, refer to "Obtaining Service" (p. 7-3). WARNING! Use only the power cord specified for the meter. The grounding…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

FieldMaxII-P User Manual 3 - 4 The type of sensor being used and the individually-selected settings determine what type of information will actually appear on the display Information that appears on the display is divided into the groups described in the following list. Figure 3-2 (p. 3-3) shows the…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

FieldMaxII-P User Manual 4 - 2 Tuning Needles Tuning needles--which divide a given tuning zone into thirty "increments"--are used to peak a laser output. As the top or bottom of a zone is reached, the tuning needles automatically move to the center of the next zone (see Figure 4-2). Zone indicator…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

FieldMaxII-P User Manual viii Preface This manual contains user information for the FieldMaxII-PTM laser energy meter. RoHS Compliance This Coherent product is RoHS compliant. Software Installation For complete software installation instructions, refer to the FieldMaxII Software Installation and…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

FieldMaxII-P User Manual vi Signal Words and Symbols in this Manual This documentation may contain sections in which particular hazards are defined or special attention is drawn to particular conditions. These sections are indicated with signal words in accordance with ANSI Z-535.6 and safety…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

…Batch size is 2 to 99,999 pulses. · View the statistics parameters if the button is pressed for two seconds or more. Wave You can configure FieldMaxII-P to automatically account for any difference between the laser wavelength and the calibration wavelength. After pressing Setup/Local, the Wave…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

FieldMaxII-P User Manual 4 - 12 In the example shown in Figure 4-6, below, the internal trigger threshold has been set to 8% (shown as a dashed line). Pulse A will definitely not generate a reliable trigger. Pulse B may generate a trigger, but not reliably. Pulses C and D will definitely generate…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

FieldMaxII-P User Manual 7 - 4 Product Shipping Instructions To prepare the product for shipping to Coherent: 1. Contact Coherent Customer Service for a Return Material Authorization number--refer to Table 7-1 (p. 7-4). 2. Attach a tag to the product that includes the name and address of the owner,…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

FieldMaxII-P User Manual 4 - 6 Setup Parameters This section explains how to select and set user-definable parameters. Setup/Local The Setup/Local button serves several purposes: 1. If an edit cycle is not in progress, pressing the Setup/Local button initiates an edit cycle. If the next button…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

…information about the Range Hint annunciator, refer to "Range Hint" (p. 4-4). Internal Triggering Mode For greatest accuracy and repeatability, FieldMaxII-P must trigger reliably for each laser pulse. Internal triggering refers to extracting an artificial trigger from the incoming signal. To…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

FieldMaxII-P User Manual 7 - 2 tently perform as expected under their actual use conditions. We are a registered ISO 9001:2000 company, our products are NIST traceable, and our calibration labs are fully ANSI Z540 compliant. In addition to the technological advantage, we also strive to deliver the…

FieldMaxII-P User Manual

FieldMaxII-P User Manual

FieldMaxII-P User Manual ii This document is copyrighted with all rights reserved. Under the copyright laws, this document may not be copied in whole or in part or reproduced in any other media without the express written permission of Coherent, Inc. Permitted copies must carry the same proprietary…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.