Search for Lasers, Laser Systems, Laser Measurment, Laser Service Coherent Inc., Worldwide websites Coherent Inc., calendar of events Coherent Inc., office locator Coherent Inc., Service Centers
     > Search
Search Coherent
Coherent Inc.
Superior Reliability & Performance
  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
Please enter a search phrase.

1 - 9 of 9 Search Results for frog
Search Suggestions: positive light | miips | pulse shaper | pulse compressor | regenerative amplifier | acousto-optic modulator | micra-5 | silhouette

1pdf document  tech_bull_sub50pulse Best match in this PDF  |  All matches in this PDF
... Optics, vol. 37, No. 9, 1638 , 20 March 1998. Temporal Intensity 0.0 0.2 0.4 0.6 0.8 1.0 -75 -50 -25 0 25 50 75 Time Intensity Figure 2: Typical FROG trace from the Spitfire sub-50 fs amplifier. Time is the horizontal axis and wavelength the vertical. Notice that the pulse exhibits no noticeable phase ...
Related Searches: pulse compressor

2pdf document  OLEReprintCoherentMay06 Best match in this PDF  |  All matches in this PDF
... potentially very difficult to implement as 128differentvoltagevaluesarerequired.In principleitispossibletouseapulsediagnostic instrument such as a FROG (Frequency ResolvedOpticalGating)orSPIDER(Spectral PhaseInterferometryforDirectElectric-field Reconstruction) to first measure the phase characteristics ...
Related Searches: miips | pulse shaper

3pdf document  PulseShaping_photoinik07 Best match in this PDF  |  All matches in this PDF
... at saturation, the losses will not affect the output power of the amplifier [5]. In conventional pulse shaping setups, measuring devices such as FROG [6] or SPIDER [7] are used for spectral analysis. These provide the feedback that sets the active pulse shaping components. These are complex measuring ...
Related Searches: miips | acousto-optic modulator | pulse shaper | micra-5

4pdf document  Sub-30fs_tech_bull Best match in this PDF  |  All matches in this PDF
... , Inc. All rights reserved. Produced: January 2003 Temporal Intensity 0.0 0.2 0.4 0.6 0.8 1.0 -75 -50 -25 0 25 50 75 Time Intensity Figure 2: Typical FROG trace from the Legend Sub-30 fs amplifier. The horizontal axis is Time and the vertical axis is Wavelength. Note that the pulse exhibits no noticeable ...
Related Searches: regenerative amplifier | positive light | grating

5pdf document  Sub-30fs_tech_bull  (PAGE 2 OF 2)
... . All rights reserved. Produced: January 2003 Temporal Intensity 0.0 0.2 0.4 0.6 0.8 1.0 -75 -50 -25 0 25 50 75 Time Int en sit y Figure 2: Typical FROG trace from the Legend Sub-30 fs amplifier. The horizontal axis is Time and the vertical axis is Wavelength. Note that the pulse exhibits no noticeable ...
Related Searches: positive light

6pdf document  PulseShaping_photoinik07  (PAGE 1 OF 3)
... at saturation, the losses will not affect the output power of the amplifier [5]. In conventional pulse shaping setups, measuring devices such as FROG [6] or SPIDER [7] are used for spectral analysis. These provide the feedback that sets the active pulse shaping components. These are complex measuring ...
Related Searches: miips | pulse shaper

7pdf document  PulseShaping_photoinik07  (PAGE 3 OF 3)
... amplified femtosecond pulses using MIIPS, Optics Express, Vol. 14, No. 20, 9537-9543, October 2006 [6] S. Akturk, R. Trebino, S. Gu, M. Kimmel, FROG für extrem kurze und relativ lange Ultrakurzpulse, Photonik 2/2005, S. 54 [7] A. Monmayrant, S. Gorza, P. Wasylczyk, I. Walmsley, Jenseits der Beugugnsmuster ...
Related Searches: micra-5 | pulse shaper | miips

8pdf document  tech_bull_sub50pulse  (PAGE 2 OF 2)
... Optics, vol. 37, No. 9, 1638 , 20 March 1998. Temporal Intensity 0.0 0.2 0.4 0.6 0.8 1.0 -75 -50 -25 0 25 50 75 Time Int en sit y Figure 2: Typical FROG trace from the Spitfire sub-50 fs amplifier. Time is the horizontal axis and wavelength the vertical. Notice that the pulse exhibits no noticeable ...

9pdf document  OLEReprintCoherentMay06  (PAGE 2 OF 3)
... very difficult to implement as 128 different voltage values are required. In principle it is possible to use a pulse diagnostic instrument such as a FROG (Frequency Resolved Optical Gating) or SPIDER (Spectral Phase Interferometry for Direct Electric-field Reconstruction) to first measure the phase ...
Related Searches: miips


Search Suggestions: positive light | miips | pulse shaper | pulse compressor | regenerative amplifier | acousto-optic modulator | micra-5 | silhouette


Site Search by  Site Search powered by SLI Systems