25 - 36 of 648 Products for 'heat sink' Page 3 of 54 |

heat sink

Book.book

Book.book

…discusses: · Increasing average power with heat sinks (this page) · Pyroelectric technology (page 23) · Damage thresholds (page 25) · Measurement linearity (page 25) · Spectral response (page 28) Increasing Average Power With Heat Sinks Using a heat sink increases the average power handling…

Book.book

Book.book

…the sensor circuit. The Table 12. Available Heat Sinks ITEM NUMBER NAME DESCRIPTION 1123430 EnergyMax small heat sink Increases average power handling on 25 mm aperture EnergyMax sensors 1123431 EnergyMaxmedium heat sink 1123432 EnergyMax large heat sink Increases average power handling on 50 mm…

Book.book

Book.book

…9 The 25 and 50 mm diameter sensors accept a user-installable, optional heat sink (see "Increasing Average Power With Heat Sinks" on page 21), which can extend the energy and/or repetition rate range. These heat sinks allow 25 mm sensors to be used up to 15W average power, and 50 mm sensors…

Book.book

Book.book

…average power specification--without the optional heat sink--may cause permanent damage to the sensor. Table 11. Average Power Ratings SENSOR MODEL APERTURE (MM) WAVELENGTH (NM) NO HEAT SINK (W) SMALL HEAT SINK (W) MEDIUM HEAT SINK (W) LARGE HEAT SINK (W) J-10MB-LE and J-10MB-HE 10 1064 4 - - -…

Book.book

Book.book

…sensor if the temperature gets too hot. Optional EnergyMax heat sinks are available to increase the average power specification of certain sensors (for more information about heat sinks, refer to "Increasing Average Power With Heat Sinks" on page 21). Use of EnergyMax sensors at average power levels…

COHERENT CORPORATE OVERVIEW

COHERENT CORPORATE OVERVIEW

pg. 2 | OBIS LX/LS Heat Sink Features · Convenient 69 mm (2.7 inch) beam height · Integrated cooling fan with vibration isolation · Output beam centered on standard table bolt pattern · Fan power connector plugs directly to OBIS laser head · Laser can be mounted on top or side for opposite…

Genesis-Taipan-Series

Genesis-Taipan-Series

…±3 488 ±3 Output Power (mW) 1000, 2000 2000, 4000 3000, 5000 Spatial Mode Multimode Bandwidth (nm) 100:1 Direct Modulation5 Available Operating Diode Current (A) 1 MHz; actual performance will be limited by the diode-driver (not included). 6 Air cooling available with appropriate heat sink and fans.

Genesis-Taipan-Series

Genesis-Taipan-Series

…532 ±3 Output Power (mW) 3000, 5000 3000, 5000, 8000 10000 Spatial Mode Multimode Bandwidth (nm) 100:1 Direct Modulation5 Available Operating Diode Current (A) 1 MHz; actual performance will be limited by the diode-driver (not included). 6 Air cooling available with appropriate heat sink and fans.

Book.book

Book.book

…laser cavity. The 25 mm and 50 mm sensors accept a user-installable, optional heat sink (see "Increasing Average Power With Heat Sinks" on page 21), which can extend the energy and/or repetition rate range. These heat sinks allow the J-25MT-10KHZ to be used up to 30W average power, and J-50MT-10KHZ…

Book.book

Book.book

…very high peak fluences. These sensors accept a user-installable, optional heat sink (see "Increasing Average Power With Heat Sinks" on page 21), which can extend either the maximum energy or average power range. These heat sinks allow the J-25MB-IR sensor to be used up to 15W average power, and the…

Book.book

Book.book

…coating damage resistance. Both sensors accept a user-installable, optional heat sink (see "Increasing Average Power With Heat Sinks" on page 21), which can extend the maximum energy or average power range. These heat sinks allow 25 mm sensors to be used up to 18W average power, and 50 mm sensors to…

COHR SapphireLPX DS 1017 1.pdf

COHR SapphireLPX DS 1017 1.pdf

…532 ±2 561 ±2 Output Power2 (mW) 300, 400 300, 400, 500 300, 400 Spatial Mode TEM00, M2 100:1 UTILITY AND ENVIRONMENTAL REQUIREMENTS Operating Voltage6 (VDC) +12.0 to 13.2 Power Consumption (W) 60W; ripple <5% peak-to-peak; line regulation <0.5%. 7 With factory-provided or other adequate heat sink.

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions