Coherent

Search Results

1 - 12 of 113 Products for 'humidity' Page 1 of 10 |

humidity

Mira 900

Mira 900

…easy adjustment of the output wavelength, pulse width and power. Optima features a fast photodiode, relative power monitor, ß-lock, CW detector, humidity sensor and an automatic starter. A wide range of accessories is available for the Mira-900. These allow operation at lower repetition-rate (Pulse…

00 SabreMFreD Preinstall.book

00 SabreMFreD Preinstall.book


recommendations for operating conditions outside of the normal
temperature and humidity range.
The conditions that lead to a situation where there can be condensation are warm and humid weather combined with water that is cooler
than the surroundings. High risk conditions…

RAPID FX

RAPID FX

…- Chiller +15 to 30°C (59 to 86°F) Vibration <0.15 g Temperature -10 to +50°C (-14 to 122°F) Temperature Gradient 15°C (59°F) per hour Relative Humidity 5% to 90% Shock 5 g in 30 ms High Energy Industrial fs-Laser for Micromachining - As part of Coherent’s industrial ultrafast laser lineup, the…

FLARE NX Short-Pulsed DPSS Lasers | Coherent

FLARE NX Short-Pulsed DPSS Lasers | Coherent

…Temperature (°C) 15 to 45°C (59 to 113°F) Ambient Storage Temperature (°C) -20 to +50°C (-4 to 122°F) Laser Head Heat Dissipation 2 (W) =40 Relative Humidity (%)(non-condensing) <80 Laser Head Dimensions (W x H x L) 93.5 x 38.25 x 160 mm (3.68 x 1.5 x 6.3 in) Laser Head Weight ~1.25 kg (2.75 lbs.)…

HELIOS

HELIOS

…Electronics Weight integrated 1.4 kg (3.0 lbs) integrated 1.4 kg (3.0 lbs) Base Plate Temperature 20 to 30 °C Storage Condition -10 to +50 °C Relative Humidity 2 80% Cable Length Laser Head none 1 m none 1 m Operating Voltage 24V ± 2 Supply Current 3 <5A <10A <5A <10A 1 Power supply not included, PC…

Mira Family

Mira Family

…daily operation, performance optimization and alignment procedures. Power/fluorescence levels, cw content of the beam, pulse train and resonator humidity levels, are all displayed by the Optima system. Furthermore, automatic starting and picosecond wavelength tuning are made possible. Only Coherent…

00 Sabre Preinstall.book

00 Sabre Preinstall.book


recommendations for operating conditions outside of the normal
temperature and humidity range.
The conditions that lead to a situation where there can be condensation are warm and humid weather combined with water that is cooler
than the surroundings. High risk conditions…

00 Laser Cooling.book

00 Laser Cooling.book

…set point. As an
example, if the current room temperature is 28°C and the relative
humidity is 68%, then the recommended inlet cooling water temperature is 35°C and the nearest relative humidity is 70%.
Selecting the cooling water temperature must also take into account
changes…

00 E-250 Pre.book

00 E-250 Pre.book

…leads to condensation is warm, humid weather
combined with fluid that is cooler than the surroundings.
High risk conditions which are likely to lead to condensation are:
· Operating the laser in a room that is not air conditioned in high
humidity environments
· Using cooling…

00 E-400 E-1000 Series Preinstall.book

00 E-400 E-1000 Series Preinstall.book

…leads to condensation is warm, humid weather
combined with fluid that is cooler than the surroundings.
High risk conditions which are likely to lead to condensation are:
· Operating the laser in a room that is not air conditioned in high
humidity environments
· Using cooling…

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

DIAMOND J-3 Series OEM Lasers Preinstallation Manual, Rev. AB

…leads to condensation is warm, humid weather
combined with fluid that is cooler than the surroundings.
High risk conditions which are likely to lead to condensation are:
· Operating the laser in a room that is not air conditioned in high
humidity environments
· Using cooling…

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

DIAMOND J-5 Series OEM Lasers Preinstallation Manual Rev AA

…leads to condensation is warm, humid weather
combined with fluid that is cooler than the surroundings.
High risk conditions which are likely to lead to condensation are:
· Operating the laser in a room that is not air conditioned in high
humidity environments
· Using cooling…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions