Ask a Question
Coherent

Search Results

Refine

Result Type

1 - 11 of 11 Products for 'hyper rapid 100 aom 355' Page 1 of 1 |
  • 1

hyper rapid 100 aom 355

COHR HyperRapid100 AOM DS 0716 4.pdf

COHR HyperRapid100 AOM DS 0716 4.pdf

…Industrial ps-Laser HYPER RAPID 100 AOM 355-SW Pulse Repetition Rate (kHz) Power(W) 0 10 20 30 40 50 60 70 80 90 100 0 100 200 300 400 500 600 700 800 900 1000 1064 nm (specification) 1064 nm (typical) 532 nm (specification) 532 nm (typical) 355 nm (specification) 355 nm (typical) Pulse Repetition…

COHR HyperRapid100 AOM DS 0716 4.pdf

COHR HyperRapid100 AOM DS 0716 4.pdf

…the process efficiency. The HYPER RAPID 100 AOM 355-SW uses an AOM as its process shutter which allows both on/off control and energy attenuation for each individual pulse. High Power Industrial ps-Laser HYPER RAPID 100 AOM 355-SW Advantages: · 1064 nm, 532 nm and 355 nm outputs · High energy at…

COHR HyperRapid100 AOM DS 0716 4.pdf

COHR HyperRapid100 AOM DS 0716 4.pdf

…764-4646 e-mail tech.sales@Coherent.com Printed in the U.S.A. MC-017-16-0M0716 Copyright ©2016 Coherent, Inc. High Power Industrial ps-Laser HYPER RAPID 100 AOM 355-SW VISIBLE AND/OR INVISIBLE LASER RADIATION. AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION POWER WAVELENGTH(S) AND PULSE…

COHR HyperRapid75 AOM DS 0716 5.pdf

COHR HyperRapid75 AOM DS 0716 5.pdf

Superior Reliability & Performance HYPER RAPID 75 AOM 355-SW High Power Industrial ps-Laser HYPER RAPID 75 AOM 355-SW Advantages: · 1064 nm, 532 nm and 355 nm outputs · High energy at high repetition rates up to 1 MHz · Pulse on demand trigger with <100 ns jitter · Pulse to pulse energy…

COHR HyperRapid75 AOM DS 0716 5.pdf

COHR HyperRapid75 AOM DS 0716 5.pdf

High Power Industrial ps-Laser HYPER RAPID 75 AOM 355-SW System Specifications HYPER RAPID 75 AOM 355-SW Center Wavelength (nm) 1064 532 355 Maximum Average Power (W) 75 28 25 Output Repetition Rate (kHz) 0 to 1000 Spatial Mode TEM00 (M2 >100:1 Beam Diameter (µm)(typical) 2650 2100 2100 Beam…

HYPER-RAPID-100-Data-Sheet.pdf

HYPER-RAPID-100-Data-Sheet.pdf

…ps-Laser HYPER RAPID 100 System Specifications HYPER RAPID 100 Wavelength (nm) 1064 (532 and 355 optional) Pulse Repetition Rate (kHz) 400 to 1000 Spatial Mode TEM00 (M2 >100:1 Beam Divergence, Full Angle (mrad) 85 Beam-Pointing Stability in Full PRF Range (rad/°C) <50 Electric Supply1 100 to 230…

HYPERRAPID100 DS 0414 5.pdf

HYPERRAPID100 DS 0414 5.pdf

…ps-Laser HYPER RAPID 100 System Specifications HYPER RAPID 100 Wavelength (nm) 1064 (532 and 355 optional) Pulse Repetition Rate (kHz) 400 to 1000 Spatial Mode TEM00 (M2 >100:1 Beam Divergence, Full Angle (mrad) 85 Beam-Pointing Stability in Full PRF Range (rad/°C) <50 Electric Supply1 100 to 230…

HYPERRAPID100 DS 0414 5.pdf

HYPERRAPID100 DS 0414 5.pdf

…ps-Laser HYPER RAPID 100 System Specifications HYPER RAPID 100 Wavelength (nm) 1064 (532 and 355 optional) Pulse Repetition Rate (kHz) 400 to 1000 Spatial Mode TEM00 (M2 >100:1 Beam Divergence, Full Angle (mrad) 85 Beam-Pointing Stability in Full PRF Range (rad/°C) <50 Electric Supply1 100 to 230…

Picosecond laser

Picosecond laser

…µJ 200-1000 IR, SHG, THG AOM Hyper Rapid 50 50 W 125 µJ 400-1000 IR, SHG, THG AOM Hyper Rapid 50-HE (high energy) 50 W 200 µJ 200-500 specified; up to 1000 IR, SHG, THG AOM Hyper Rapid 75 75 W 150 µJ 400-1000 IR, SHG, THG AOM Hyper Rapid 100 100 W 250 µJ 400-1000 IR, SHG, THG AOM 5 of 27 HYPER RAPID

Picosecond laser

Picosecond laser

…µJ 200-1000 IR, SHG, THG AOM Hyper Rapid 50 50 W 125 µJ 400-1000 IR, SHG, THG AOM Hyper Rapid 50-HE (high energy) 50 W 200 µJ 200-500 specified; up to 1000 IR, SHG, THG AOM Hyper Rapid 75 75 W 150 µJ 400-1000 IR, SHG, THG AOM Hyper Rapid 100 100 W 250 µJ 400-1000 IR, SHG, THG AOM 5 of 27 HYPER RAPID

HYPERRAPID100.pdf

HYPERRAPID100.pdf

…ps-Laser HYPER RAPID 100 System Specifications HYPER RAPID 100 Wavelength (nm) 1064 (532 and 355 optional) Pulse Repetition Rate (kHz) 400 to 1000 Spatial Mode TEM00 (M2 >100:1 Beam Divergence, Full Angle (mrad) 85 Beam-Pointing Stability in Full PRF Range (rad/°C) <50 Electric Supply1 100 to 230…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions