COHR HRNX SmartCleave DS 0617 1.pdf

COHR HRNX SmartCleave DS 0617 1.pdf

…edge quality. HyperRapid NX SmartCleave delivers over 100W output power, with burst energy above 720 µJ at repetition rate up to 140 kHz. The 1064-50 model is optimal for cost-sensitive applications, where the 1064-100 enables high speed applications. HyperRapid NX SmartCleave features HyperRapid NX

COHR HRNX SmartCleave DS 0717 4.pdf

COHR HRNX SmartCleave DS 0717 4.pdf

…edge quality. HyperRapid NX SmartCleave delivers over 100W output power, with burst energy above 720 µJ at repetition rate up to 140 kHz. The 1064-50 model is optimal for cost-sensitive applications, while the 1064-100 enables high speed applications. HyperRapid NX SmartCleave features HyperRapid NX

COHR HRNX SmartCleave DS 0717 4.pdf

COHR HRNX SmartCleave DS 0717 4.pdf

…edge quality. HyperRapid NX SmartCleave delivers over 100W output power, with burst energy above 720 µJ at repetition rate up to 140 kHz. The 1064-50 model is optimal for cost-sensitive applications, while the 1064-100 enables high speed applications. HyperRapid NX SmartCleave features HyperRapid NX

Picosecond laser

Picosecond laser

HyperRapid NX 48 of 63 COMMAND TYPE MIN MAX UNIT DESCRIPTION Remark WHC -- -- Clear the warning history Clears the warning history ?WNAME nnn STR -- Get the description of a warning code Returns the description of a warning code nnn ?WT FLT °C Get WaterMonitor water temperature Returns the cooling…

Picosecond laser

Picosecond laser

HyperRapid NX 48 of 63 COMMAND TYPE MIN MAX UNIT DESCRIPTION Remark WHC -- -- Clear the warning history Clears the warning history ?WNAME nnn STR -- Get the description of a warning code Returns the description of a warning code nnn ?WT FLT °C Get WaterMonitor water temperature Returns the cooling…

Picosecond laser

Picosecond laser

HyperRapid NX 48 of 63 COMMAND TYPE MIN MAX UNIT DESCRIPTION Remark WHC -- -- Clear the warning history Clears the warning history ?WNAME nnn STR -- Get the description of a warning code Returns the description of a warning code nnn ?WT FLT °C Get WaterMonitor water temperature Returns the cooling…

COHR HyperRapidNX DS 1016revA 7.pdf

COHR HyperRapidNX DS 1016revA 7.pdf

The New Generation of High Power Industrial Picosecond Laser HyperRapid NX System Specifications1,2,3,4,5 System Specifications1,2,3,4,5 HyperRapid NX Single Wavelength Output (nm) 1064 532 355 1064 532 355 Amplifier Pulse Repetition Rate (kHz) 200 to 1000 400 to 1000 Output Pulse Repetition Rate…

COHR HyperRapidNX DS 1016revA 7.pdf

COHR HyperRapidNX DS 1016revA 7.pdf

The New Generation of High Power Industrial Picosecond Laser HyperRapid NX System Specifications1,2,3,4,5 System Specifications1,2,3,4,5 HyperRapid NX Single Wavelength Output (nm) 1064 532 355 1064 532 355 Amplifier Pulse Repetition Rate (kHz) 200 to 1000 400 to 1000 Output Pulse Repetition Rate…

COHR HyperRapidNX DS 1016revA 7.pdf

COHR HyperRapidNX DS 1016revA 7.pdf

The New Generation of High Power Industrial Picosecond Laser HyperRapid NX System Specifications1,2,3,4,5 System Specifications1,2,3,4,5 HyperRapid NX Single Wavelength Output (nm) 1064 532 355 1064 532 355 Amplifier Pulse Repetition Rate (kHz) 200 to 1000 400 to 1000 Output Pulse Repetition Rate…

Picosecond laser

Picosecond laser

HyperRapid NX 34 of 63 Step Image Description 1 Start with the return part (5) and screw it into the "RETURN" opening. Make sure that it is aligned straight downwards (bypass facing to the left) as shown in the image. For this procedure a tool should not be necessary (tighten by hand). 2 Screw the…

Picosecond laser

Picosecond laser

…end of the short hose (6) into the left side of the filter assembly (3). Screw the mounting bracket (attached to the filter) with both M5-screws (2) to the rear side of the chiller (top edge, using the tapped holes in the chiller-housing) in order to hold the filter in place. 35 of 63 HyperRapid NX

Picosecond laser

Picosecond laser

HyperRapid NX 34 of 63 Step Image Description 1 Start with the return part (5) and screw it into the "RETURN" opening. Make sure that it is aligned straight downwards (bypass facing to the left) as shown in the image. For this procedure a tool should not be necessary (tighten by hand). 2 Screw the…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.