Search for Lasers, Laser Systems, Laser Measurment, Laser Service Coherent Inc., Worldwide websites Coherent Inc., calendar of events Coherent Inc., office locator Coherent Inc., Service Centers
     > Search
Search Coherent
Coherent Inc.
Superior Reliability & Performance
  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
Please enter a search phrase.

1 - 10 of 20 Search Results for irradiance
Search Suggestions: energy meter | epm 2000 | epm1000 | epm2000 | 0011-5140 | epm 2000 manual

1pdf document  Semi_LasersTargetChipFabricationRev2 Best match in this PDF  |  All matches in this PDF
lates to wafer diameter. As the industry moved from 200- to 300-mm production, designers made wafers thicker to maintain their mechanical integrity when cut from the silicon crystal. Today, most 300-mm wafers are 720 to 750 µm thick. Several integrated circuit design issues and end-use applications ...
Related Searches: laser drilling | andrew masters | laser scribing | scribing

2pdf document  ACF45F Best match in this PDF  |  All matches in this PDF
... 1/e2 value by 1.414. Measured values may differ. 8 The distance along the axis of the unobstructed beam from the laser to the eye, beyond which the irradiance is not expected to exceed that
Related Searches: innova 300 manual | purelight | innova 70 user manual | argon

3pdf document  pdf_232 Best match in this PDF  |  All matches in this PDF
1 important OClO molecule, and show how velocity map imaging reveals the production of extremely hot OCl fragments. Potential consequences, in atmospheric chemistry, from this extreme channeling of the excess energy into vibrational excitation will be mentioned. Typical models of the chemical processes ...
Related Searches: solar cell scribing | xenon fluoride lasers | fused silica | two photon

4pdf document  3sigmaAddendum Best match in this PDF  |  All matches in this PDF
... . That is, the average power applied to the probe is too high, or there is a technical problem with the 3sigma. Average power is computed as irradiance times frequency. Example: 1 J at 1 Hz = 1 W average power. Reducing the irradiance or the frequency of the laser can reduce average power. QI-19.162 ...
Related Searches: 3sigma

5EPM2000 Series
EPM2000 Series Power and Energy Meters Measures power levels from 100 µW to 10 kW; energy levels from 100 fJ to 300J. Superior Reliability & Performance Lasers and Laser-based Systems Laser Measurement and Control Precision Optics Related Accessories Laser Applications Used Holography Printing ...
Related Searches: 0011-5140 | epm 2000 manual | epm | operation manual

6EPM2000 Series
EPM2000 Series Power and Energy Meters Measures power levels from 100 µW to 10 kW; energy levels from 100 fJ to 300J. Superior Reliability & Performance Lasers and Laser-based Systems Laser Measurement and Control Precision Optics Related Accessories Measures power and energy Dual channel Ratio ...
Related Searches: epm 2000 | epm 1000 manual | epm2000 | labview

7EPM2000 Series
EPM2000 Series Power and Energy Meters Measures power levels from 100 µW to 10 kW; energy levels from 100 fJ to 300J. Sales Support: 1-800-343-4912 NEW! Smart Finder Tool Search by Sensors and/or Meters.  -- select product type --  Find a Sensor Find a Meter Find a Meter and Sensor   ...
Related Searches: epm 2000

8Diamond Drilling with DPSS Lasers
... drilled a clean, round hole in a chemical vapor deposition (CVD) diamond film of 750 µm thickness. This was probably due to the laser’s high irradiance and the use of trepanning. Spot size (µm) Fluence (J/cm²) Drill Time (sec) Irradiance (W/cm²) 10  140  6.25 9.2 X 10 9 Fig. 1 - Drilling ...
Related Searches: diamond | avia 266-3000

9pdf document  Sabre_ent_ds Best match in this PDF  |  All matches in this PDF
... 1/e2 value by 1.414. Measured values may differ. 8 The distance along the axis of the unobstructed beam from the laser to the eye, beyond which the irradiance is not expected to exceed that
Related Searches: purelight | sabre | krypton | operation manual

104omega
... the sensor's voltage response, temperature and wavelength correction tables, and is ready for precise, pulsed laser characterization. Measure irradiance (mW/cm 2), dose (total energy, J), fluence (mJ/cm 2), and much more. Questions about operation can be answered by calling up the onboard user's manual ...


Search Suggestions: energy meter | epm 2000 | epm1000 | epm2000 | 0011-5140 | epm 2000 manual
Page 1 2 of 2 | Next


Site Search by  Site Search powered by SLI Systems